Cargando…

Recognition of the dense fine speckled (DFS) pattern remains challenging: results from an international internet-based survey

PURPOSE: The dense fine speckled (DFS) pattern as detected by indirect immunofluorescence (IIF) on HEp-2 cells has been associated with several inflammatory diseases but is most commonly observed in individuals that do not have an antinuclear antibody (ANA)-associated rheumatic disease and even in a...

Descripción completa

Detalles Bibliográficos
Autores principales: Bentow, Chelsea, Fritzler, Marvin J., Mummert, Eckart, Mahler, Michael
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Springer International Publishing 2016
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4939145/
https://www.ncbi.nlm.nih.gov/pubmed/27395414
http://dx.doi.org/10.1007/s13317-016-0081-2
_version_ 1782441959589150720
author Bentow, Chelsea
Fritzler, Marvin J.
Mummert, Eckart
Mahler, Michael
author_facet Bentow, Chelsea
Fritzler, Marvin J.
Mummert, Eckart
Mahler, Michael
author_sort Bentow, Chelsea
collection PubMed
description PURPOSE: The dense fine speckled (DFS) pattern as detected by indirect immunofluorescence (IIF) on HEp-2 cells has been associated with several inflammatory diseases but is most commonly observed in individuals that do not have an antinuclear antibody (ANA)-associated rheumatic disease and even in apparently healthy individuals. Consequently, the accurate identification and correct reporting of this IIF pattern is of utmost importance and accordingly has been recognized by several international study groups for the detection of ANA. Furthermore, the DFS IIF pattern has recently been recommended as a competency level recognition pattern by the International Consensus on Antinuclear Antibody (ANA) Pattern (ICAP, http://www.anapatterns.org/) Committee. The objective of this study was to use an internet-based survey to assess how accurately the DFS IIF pattern was recognized by experienced technologists. METHODS: High-resolution digital IIF images were captured using the automated IIF NOVA View instrument (Inova Diagnostics, San Diego, CA). Ten images were posted in an anonymous, international, internet-based interpretive survey. Two hundred and thirty IIF technologists were invited to participate. Four of the images in the survey were from previously characterized serum samples with classical ANA IIF patterns (nucleolar, centromere, homogeneous, and speckled) and two of the images were from samples with a DFS IIF ANA pattern and isolated anti-DFS70 antibodies as determined by a chemiluminescence immunoassay. The remaining four images were from sera with the classic IIF ANA patterns referred to above and mixed with a monospecific anti-DFS70-positive sample. The survey included multiple choice selections: homogeneous, DFS, centromere, nucleolar, speckled, other, or unrecognizable. RESULTS: 125 of the 230 participants who completed the survey had diverse levels of experience in IIF pattern recognition on HEp-2 cells ranging from <1 year to >10 years of experience (average >10 years). Participants had a high concordance in correctly classifying the classical ANA IIF patterns: ranging from 95.2 % for centromere to 74.4 % for nucleolar patterns. The unmixed DFS pattern was recognized with significantly lower accuracy (~50 %; p < 0.05). However, less than 10 % correctly identified mixed patterns derived from the sera containing both clinically relevant ANA and anti-DFS70 antibodies. CONCLUSIONS: Recognizing the DFS ANA IIF pattern and mixed IIF patterns composed of DFS + clinically relevant ANA patterns poses a significant challenge. Consequently, it seems imperative that DFS-specific immunoassays should be used to confirm the presence of anti-DFS70 antibodies before definitive results are reported to physicians.
format Online
Article
Text
id pubmed-4939145
institution National Center for Biotechnology Information
language English
publishDate 2016
publisher Springer International Publishing
record_format MEDLINE/PubMed
spelling pubmed-49391452016-07-11 Recognition of the dense fine speckled (DFS) pattern remains challenging: results from an international internet-based survey Bentow, Chelsea Fritzler, Marvin J. Mummert, Eckart Mahler, Michael Auto Immun Highlights Original Article PURPOSE: The dense fine speckled (DFS) pattern as detected by indirect immunofluorescence (IIF) on HEp-2 cells has been associated with several inflammatory diseases but is most commonly observed in individuals that do not have an antinuclear antibody (ANA)-associated rheumatic disease and even in apparently healthy individuals. Consequently, the accurate identification and correct reporting of this IIF pattern is of utmost importance and accordingly has been recognized by several international study groups for the detection of ANA. Furthermore, the DFS IIF pattern has recently been recommended as a competency level recognition pattern by the International Consensus on Antinuclear Antibody (ANA) Pattern (ICAP, http://www.anapatterns.org/) Committee. The objective of this study was to use an internet-based survey to assess how accurately the DFS IIF pattern was recognized by experienced technologists. METHODS: High-resolution digital IIF images were captured using the automated IIF NOVA View instrument (Inova Diagnostics, San Diego, CA). Ten images were posted in an anonymous, international, internet-based interpretive survey. Two hundred and thirty IIF technologists were invited to participate. Four of the images in the survey were from previously characterized serum samples with classical ANA IIF patterns (nucleolar, centromere, homogeneous, and speckled) and two of the images were from samples with a DFS IIF ANA pattern and isolated anti-DFS70 antibodies as determined by a chemiluminescence immunoassay. The remaining four images were from sera with the classic IIF ANA patterns referred to above and mixed with a monospecific anti-DFS70-positive sample. The survey included multiple choice selections: homogeneous, DFS, centromere, nucleolar, speckled, other, or unrecognizable. RESULTS: 125 of the 230 participants who completed the survey had diverse levels of experience in IIF pattern recognition on HEp-2 cells ranging from <1 year to >10 years of experience (average >10 years). Participants had a high concordance in correctly classifying the classical ANA IIF patterns: ranging from 95.2 % for centromere to 74.4 % for nucleolar patterns. The unmixed DFS pattern was recognized with significantly lower accuracy (~50 %; p < 0.05). However, less than 10 % correctly identified mixed patterns derived from the sera containing both clinically relevant ANA and anti-DFS70 antibodies. CONCLUSIONS: Recognizing the DFS ANA IIF pattern and mixed IIF patterns composed of DFS + clinically relevant ANA patterns poses a significant challenge. Consequently, it seems imperative that DFS-specific immunoassays should be used to confirm the presence of anti-DFS70 antibodies before definitive results are reported to physicians. Springer International Publishing 2016-07-09 /pmc/articles/PMC4939145/ /pubmed/27395414 http://dx.doi.org/10.1007/s13317-016-0081-2 Text en © The Author(s) 2016 Open AccessThis article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made.
spellingShingle Original Article
Bentow, Chelsea
Fritzler, Marvin J.
Mummert, Eckart
Mahler, Michael
Recognition of the dense fine speckled (DFS) pattern remains challenging: results from an international internet-based survey
title Recognition of the dense fine speckled (DFS) pattern remains challenging: results from an international internet-based survey
title_full Recognition of the dense fine speckled (DFS) pattern remains challenging: results from an international internet-based survey
title_fullStr Recognition of the dense fine speckled (DFS) pattern remains challenging: results from an international internet-based survey
title_full_unstemmed Recognition of the dense fine speckled (DFS) pattern remains challenging: results from an international internet-based survey
title_short Recognition of the dense fine speckled (DFS) pattern remains challenging: results from an international internet-based survey
title_sort recognition of the dense fine speckled (dfs) pattern remains challenging: results from an international internet-based survey
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4939145/
https://www.ncbi.nlm.nih.gov/pubmed/27395414
http://dx.doi.org/10.1007/s13317-016-0081-2
work_keys_str_mv AT bentowchelsea recognitionofthedensefinespeckleddfspatternremainschallengingresultsfromaninternationalinternetbasedsurvey
AT fritzlermarvinj recognitionofthedensefinespeckleddfspatternremainschallengingresultsfromaninternationalinternetbasedsurvey
AT mummerteckart recognitionofthedensefinespeckleddfspatternremainschallengingresultsfromaninternationalinternetbasedsurvey
AT mahlermichael recognitionofthedensefinespeckleddfspatternremainschallengingresultsfromaninternationalinternetbasedsurvey