Cargando…

Feasibility and Safety of Absorbable Knotless Wound Closure Device in Laparoscopic Myomectomy

Purpose. Myomectomy has been performed through laparoscopy. Suturing is known as rate-limiting step in laparoscopic myomectomy. The present study was aimed at comparing the clinical outcomes of absorbable knotless wound closure device with the results of conventional suturing. Methods. This prospect...

Descripción completa

Detalles Bibliográficos
Autores principales: Chan, Chying-Chyuan, Lee, Ching-Yu
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Hindawi Publishing Corporation 2016
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4939335/
https://www.ncbi.nlm.nih.gov/pubmed/27429977
http://dx.doi.org/10.1155/2016/2849476
_version_ 1782441991413432320
author Chan, Chying-Chyuan
Lee, Ching-Yu
author_facet Chan, Chying-Chyuan
Lee, Ching-Yu
author_sort Chan, Chying-Chyuan
collection PubMed
description Purpose. Myomectomy has been performed through laparoscopy. Suturing is known as rate-limiting step in laparoscopic myomectomy. The present study was aimed at comparing the clinical outcomes of absorbable knotless wound closure device with the results of conventional suturing. Methods. This prospective study included 62 women who underwent laparoscopic myomectomy at Taipei City Hospital, Zhongxiao Branch, from January 2010 through to August 2012. The patients were randomized into two groups according to suturing materials, the knotless group and the 2-0 Vicryl suture group. Patient demographics, overall operative time, and intraoperative blood loss were compared between two groups. Results. Demographic characteristics and laboratory variables before surgery were comparable. Operative time was significantly shorter in knotless group compared with that in 2-0 Vicryl suture group (112 ± 47 versus 147 ± 63 minutes; p < 0.05). The results revealed a significant difference in intraoperative blood loss between two groups (knotless versus 2-0 Vicryl: 112.8 ± 54.2 versus 143.6 ± 64.9). Use of absorbable knotless wound closure device was associated with greater hemostasis compared with that of 2-0 Vicryl. During a 2-year follow-up period, 12 patients (46.2%) from the group with absorbable knotless wound closure device and 14 patients (38.9%) from 2-0 Vicryl suture group became pregnant. Conclusion. Closure of myometrium using absorbable knotless wound closure device after laparoscopic myomectomy resulted in a shorter operative time and less blood loss.
format Online
Article
Text
id pubmed-4939335
institution National Center for Biotechnology Information
language English
publishDate 2016
publisher Hindawi Publishing Corporation
record_format MEDLINE/PubMed
spelling pubmed-49393352016-07-17 Feasibility and Safety of Absorbable Knotless Wound Closure Device in Laparoscopic Myomectomy Chan, Chying-Chyuan Lee, Ching-Yu Biomed Res Int Research Article Purpose. Myomectomy has been performed through laparoscopy. Suturing is known as rate-limiting step in laparoscopic myomectomy. The present study was aimed at comparing the clinical outcomes of absorbable knotless wound closure device with the results of conventional suturing. Methods. This prospective study included 62 women who underwent laparoscopic myomectomy at Taipei City Hospital, Zhongxiao Branch, from January 2010 through to August 2012. The patients were randomized into two groups according to suturing materials, the knotless group and the 2-0 Vicryl suture group. Patient demographics, overall operative time, and intraoperative blood loss were compared between two groups. Results. Demographic characteristics and laboratory variables before surgery were comparable. Operative time was significantly shorter in knotless group compared with that in 2-0 Vicryl suture group (112 ± 47 versus 147 ± 63 minutes; p < 0.05). The results revealed a significant difference in intraoperative blood loss between two groups (knotless versus 2-0 Vicryl: 112.8 ± 54.2 versus 143.6 ± 64.9). Use of absorbable knotless wound closure device was associated with greater hemostasis compared with that of 2-0 Vicryl. During a 2-year follow-up period, 12 patients (46.2%) from the group with absorbable knotless wound closure device and 14 patients (38.9%) from 2-0 Vicryl suture group became pregnant. Conclusion. Closure of myometrium using absorbable knotless wound closure device after laparoscopic myomectomy resulted in a shorter operative time and less blood loss. Hindawi Publishing Corporation 2016 2016-06-27 /pmc/articles/PMC4939335/ /pubmed/27429977 http://dx.doi.org/10.1155/2016/2849476 Text en Copyright © 2016 C.-C. Chan and C.-Y. Lee. https://creativecommons.org/licenses/by/4.0/ This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Research Article
Chan, Chying-Chyuan
Lee, Ching-Yu
Feasibility and Safety of Absorbable Knotless Wound Closure Device in Laparoscopic Myomectomy
title Feasibility and Safety of Absorbable Knotless Wound Closure Device in Laparoscopic Myomectomy
title_full Feasibility and Safety of Absorbable Knotless Wound Closure Device in Laparoscopic Myomectomy
title_fullStr Feasibility and Safety of Absorbable Knotless Wound Closure Device in Laparoscopic Myomectomy
title_full_unstemmed Feasibility and Safety of Absorbable Knotless Wound Closure Device in Laparoscopic Myomectomy
title_short Feasibility and Safety of Absorbable Knotless Wound Closure Device in Laparoscopic Myomectomy
title_sort feasibility and safety of absorbable knotless wound closure device in laparoscopic myomectomy
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4939335/
https://www.ncbi.nlm.nih.gov/pubmed/27429977
http://dx.doi.org/10.1155/2016/2849476
work_keys_str_mv AT chanchyingchyuan feasibilityandsafetyofabsorbableknotlesswoundclosuredeviceinlaparoscopicmyomectomy
AT leechingyu feasibilityandsafetyofabsorbableknotlesswoundclosuredeviceinlaparoscopicmyomectomy