Cargando…

Three-Dimensional Visualization of Myocardial Ischemia Based on the Standard Twelve-Lead Electrocardiogram

A novel method was proposed for transforming the ischemic information in the 12-lead electrocardiogram (ECG) into the pseudo-color pattern displayed on a 3D heart model based on the projection of a ST injury vector in this study. The projection of the ST injury vector at a point on the heart surface...

Descripción completa

Detalles Bibliográficos
Autores principales: Ma, Ying, Sheng, Yang, Ruixia, Tian, Xun, Chen
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Hindawi Publishing Corporation 2016
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4940520/
https://www.ncbi.nlm.nih.gov/pubmed/27433278
http://dx.doi.org/10.1155/2016/7697980
_version_ 1782442157810909184
author Ma, Ying
Sheng, Yang
Ruixia, Tian
Xun, Chen
author_facet Ma, Ying
Sheng, Yang
Ruixia, Tian
Xun, Chen
author_sort Ma, Ying
collection PubMed
description A novel method was proposed for transforming the ischemic information in the 12-lead electrocardiogram (ECG) into the pseudo-color pattern displayed on a 3D heart model based on the projection of a ST injury vector in this study. The projection of the ST injury vector at a point on the heart surface was used for identifying the presence of myocardial ischemia by the difference between the projection value and the detection threshold. Supposing that myocardial ischemia was uniform and continuous, the location and range of myocardial ischemia could be accurately calculated and visually displayed in a color-encoding way. The diagnoses of the same patient were highly consistent (kappa coefficient k = 0.9030) between the proposed method used by ordinary people lacking medical knowledge and the standard 12-lead ECG used by experienced cardiologists. In addition, the diagnostic accuracy of the proposed method was further confirmed by the coronary angiography. The results of this study provide a new way to promote the development of the 3D visualization of the standard 12-lead ECG, which has a great help for inexperienced doctors or ordinary family members in their diagnosis of patients with myocardial ischemia.
format Online
Article
Text
id pubmed-4940520
institution National Center for Biotechnology Information
language English
publishDate 2016
publisher Hindawi Publishing Corporation
record_format MEDLINE/PubMed
spelling pubmed-49405202016-07-18 Three-Dimensional Visualization of Myocardial Ischemia Based on the Standard Twelve-Lead Electrocardiogram Ma, Ying Sheng, Yang Ruixia, Tian Xun, Chen Comput Math Methods Med Research Article A novel method was proposed for transforming the ischemic information in the 12-lead electrocardiogram (ECG) into the pseudo-color pattern displayed on a 3D heart model based on the projection of a ST injury vector in this study. The projection of the ST injury vector at a point on the heart surface was used for identifying the presence of myocardial ischemia by the difference between the projection value and the detection threshold. Supposing that myocardial ischemia was uniform and continuous, the location and range of myocardial ischemia could be accurately calculated and visually displayed in a color-encoding way. The diagnoses of the same patient were highly consistent (kappa coefficient k = 0.9030) between the proposed method used by ordinary people lacking medical knowledge and the standard 12-lead ECG used by experienced cardiologists. In addition, the diagnostic accuracy of the proposed method was further confirmed by the coronary angiography. The results of this study provide a new way to promote the development of the 3D visualization of the standard 12-lead ECG, which has a great help for inexperienced doctors or ordinary family members in their diagnosis of patients with myocardial ischemia. Hindawi Publishing Corporation 2016 2016-06-28 /pmc/articles/PMC4940520/ /pubmed/27433278 http://dx.doi.org/10.1155/2016/7697980 Text en Copyright © 2016 Ying Ma et al. https://creativecommons.org/licenses/by/4.0/ This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Research Article
Ma, Ying
Sheng, Yang
Ruixia, Tian
Xun, Chen
Three-Dimensional Visualization of Myocardial Ischemia Based on the Standard Twelve-Lead Electrocardiogram
title Three-Dimensional Visualization of Myocardial Ischemia Based on the Standard Twelve-Lead Electrocardiogram
title_full Three-Dimensional Visualization of Myocardial Ischemia Based on the Standard Twelve-Lead Electrocardiogram
title_fullStr Three-Dimensional Visualization of Myocardial Ischemia Based on the Standard Twelve-Lead Electrocardiogram
title_full_unstemmed Three-Dimensional Visualization of Myocardial Ischemia Based on the Standard Twelve-Lead Electrocardiogram
title_short Three-Dimensional Visualization of Myocardial Ischemia Based on the Standard Twelve-Lead Electrocardiogram
title_sort three-dimensional visualization of myocardial ischemia based on the standard twelve-lead electrocardiogram
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4940520/
https://www.ncbi.nlm.nih.gov/pubmed/27433278
http://dx.doi.org/10.1155/2016/7697980
work_keys_str_mv AT maying threedimensionalvisualizationofmyocardialischemiabasedonthestandardtwelveleadelectrocardiogram
AT shengyang threedimensionalvisualizationofmyocardialischemiabasedonthestandardtwelveleadelectrocardiogram
AT ruixiatian threedimensionalvisualizationofmyocardialischemiabasedonthestandardtwelveleadelectrocardiogram
AT xunchen threedimensionalvisualizationofmyocardialischemiabasedonthestandardtwelveleadelectrocardiogram