Cargando…
Three-Dimensional Visualization of Myocardial Ischemia Based on the Standard Twelve-Lead Electrocardiogram
A novel method was proposed for transforming the ischemic information in the 12-lead electrocardiogram (ECG) into the pseudo-color pattern displayed on a 3D heart model based on the projection of a ST injury vector in this study. The projection of the ST injury vector at a point on the heart surface...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Hindawi Publishing Corporation
2016
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4940520/ https://www.ncbi.nlm.nih.gov/pubmed/27433278 http://dx.doi.org/10.1155/2016/7697980 |
_version_ | 1782442157810909184 |
---|---|
author | Ma, Ying Sheng, Yang Ruixia, Tian Xun, Chen |
author_facet | Ma, Ying Sheng, Yang Ruixia, Tian Xun, Chen |
author_sort | Ma, Ying |
collection | PubMed |
description | A novel method was proposed for transforming the ischemic information in the 12-lead electrocardiogram (ECG) into the pseudo-color pattern displayed on a 3D heart model based on the projection of a ST injury vector in this study. The projection of the ST injury vector at a point on the heart surface was used for identifying the presence of myocardial ischemia by the difference between the projection value and the detection threshold. Supposing that myocardial ischemia was uniform and continuous, the location and range of myocardial ischemia could be accurately calculated and visually displayed in a color-encoding way. The diagnoses of the same patient were highly consistent (kappa coefficient k = 0.9030) between the proposed method used by ordinary people lacking medical knowledge and the standard 12-lead ECG used by experienced cardiologists. In addition, the diagnostic accuracy of the proposed method was further confirmed by the coronary angiography. The results of this study provide a new way to promote the development of the 3D visualization of the standard 12-lead ECG, which has a great help for inexperienced doctors or ordinary family members in their diagnosis of patients with myocardial ischemia. |
format | Online Article Text |
id | pubmed-4940520 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2016 |
publisher | Hindawi Publishing Corporation |
record_format | MEDLINE/PubMed |
spelling | pubmed-49405202016-07-18 Three-Dimensional Visualization of Myocardial Ischemia Based on the Standard Twelve-Lead Electrocardiogram Ma, Ying Sheng, Yang Ruixia, Tian Xun, Chen Comput Math Methods Med Research Article A novel method was proposed for transforming the ischemic information in the 12-lead electrocardiogram (ECG) into the pseudo-color pattern displayed on a 3D heart model based on the projection of a ST injury vector in this study. The projection of the ST injury vector at a point on the heart surface was used for identifying the presence of myocardial ischemia by the difference between the projection value and the detection threshold. Supposing that myocardial ischemia was uniform and continuous, the location and range of myocardial ischemia could be accurately calculated and visually displayed in a color-encoding way. The diagnoses of the same patient were highly consistent (kappa coefficient k = 0.9030) between the proposed method used by ordinary people lacking medical knowledge and the standard 12-lead ECG used by experienced cardiologists. In addition, the diagnostic accuracy of the proposed method was further confirmed by the coronary angiography. The results of this study provide a new way to promote the development of the 3D visualization of the standard 12-lead ECG, which has a great help for inexperienced doctors or ordinary family members in their diagnosis of patients with myocardial ischemia. Hindawi Publishing Corporation 2016 2016-06-28 /pmc/articles/PMC4940520/ /pubmed/27433278 http://dx.doi.org/10.1155/2016/7697980 Text en Copyright © 2016 Ying Ma et al. https://creativecommons.org/licenses/by/4.0/ This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Research Article Ma, Ying Sheng, Yang Ruixia, Tian Xun, Chen Three-Dimensional Visualization of Myocardial Ischemia Based on the Standard Twelve-Lead Electrocardiogram |
title | Three-Dimensional Visualization of Myocardial Ischemia Based on the Standard Twelve-Lead Electrocardiogram |
title_full | Three-Dimensional Visualization of Myocardial Ischemia Based on the Standard Twelve-Lead Electrocardiogram |
title_fullStr | Three-Dimensional Visualization of Myocardial Ischemia Based on the Standard Twelve-Lead Electrocardiogram |
title_full_unstemmed | Three-Dimensional Visualization of Myocardial Ischemia Based on the Standard Twelve-Lead Electrocardiogram |
title_short | Three-Dimensional Visualization of Myocardial Ischemia Based on the Standard Twelve-Lead Electrocardiogram |
title_sort | three-dimensional visualization of myocardial ischemia based on the standard twelve-lead electrocardiogram |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4940520/ https://www.ncbi.nlm.nih.gov/pubmed/27433278 http://dx.doi.org/10.1155/2016/7697980 |
work_keys_str_mv | AT maying threedimensionalvisualizationofmyocardialischemiabasedonthestandardtwelveleadelectrocardiogram AT shengyang threedimensionalvisualizationofmyocardialischemiabasedonthestandardtwelveleadelectrocardiogram AT ruixiatian threedimensionalvisualizationofmyocardialischemiabasedonthestandardtwelveleadelectrocardiogram AT xunchen threedimensionalvisualizationofmyocardialischemiabasedonthestandardtwelveleadelectrocardiogram |