Cargando…

A Stereomicroscopic Evaluation of Dentinal Cracks at Different Instrumentation Lengths by Using Different Rotary Files (ProTaper Universal, ProTaper Next, and HyFlex CM): An Ex Vivo Study

Introduction. The aim of the present study was to evaluate the dentinal cracks after root canal preparation with rotary files: Gates Glidden, ProTaper Universal, ProTaper Next, and HyFlex CM at different instrumentation lengths. Methodology. Sixty-five mandibular premolars were mounted in the acryli...

Descripción completa

Detalles Bibliográficos
Autores principales: Ashraf, Fauzia, Shankarappa, Pushpa, Misra, Abhinav, Sawhney, Asheesh, Sridevi, Nandamuri, Singh, Anu
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Hindawi Publishing Corporation 2016
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4942666/
https://www.ncbi.nlm.nih.gov/pubmed/27446636
http://dx.doi.org/10.1155/2016/8379865
_version_ 1782442457016827904
author Ashraf, Fauzia
Shankarappa, Pushpa
Misra, Abhinav
Sawhney, Asheesh
Sridevi, Nandamuri
Singh, Anu
author_facet Ashraf, Fauzia
Shankarappa, Pushpa
Misra, Abhinav
Sawhney, Asheesh
Sridevi, Nandamuri
Singh, Anu
author_sort Ashraf, Fauzia
collection PubMed
description Introduction. The aim of the present study was to evaluate the dentinal cracks after root canal preparation with rotary files: Gates Glidden, ProTaper Universal, ProTaper Next, and HyFlex CM at different instrumentation lengths. Methodology. Sixty-five mandibular premolars were mounted in the acrylic tube with simulated periodontal ligaments and the apex was exposed. The root canals were instrumented with different rotary files, namely, ProTaper Universal, ProTaper Next, and HyFlex CM, to the major apical foramen (AF), short AF, and beyond AF. The root apex was stained with 1% methylene blue dye and digital images of apical surface of every tooth were taken and development of dentinal defects was determined by using stereomicroscope. Multinomial logistic regression test was performed to identify influencing factors. Results. Instrumentation with rotary files terminated 2 mm short AF and did not cause any cracks. Significantly less cracks were seen when instrumentation with rotary files terminated 1 mm short apical foramen when compared with the instrumentation terminated at or beyond apical foramen (p < 0.05). Conclusion. ProTaper Universal rotary files caused more dentinal cracks than ProTaper Next and HyFlex CM. Instrumentation short AF reduced the risk of dentinal defects.
format Online
Article
Text
id pubmed-4942666
institution National Center for Biotechnology Information
language English
publishDate 2016
publisher Hindawi Publishing Corporation
record_format MEDLINE/PubMed
spelling pubmed-49426662016-07-21 A Stereomicroscopic Evaluation of Dentinal Cracks at Different Instrumentation Lengths by Using Different Rotary Files (ProTaper Universal, ProTaper Next, and HyFlex CM): An Ex Vivo Study Ashraf, Fauzia Shankarappa, Pushpa Misra, Abhinav Sawhney, Asheesh Sridevi, Nandamuri Singh, Anu Scientifica (Cairo) Research Article Introduction. The aim of the present study was to evaluate the dentinal cracks after root canal preparation with rotary files: Gates Glidden, ProTaper Universal, ProTaper Next, and HyFlex CM at different instrumentation lengths. Methodology. Sixty-five mandibular premolars were mounted in the acrylic tube with simulated periodontal ligaments and the apex was exposed. The root canals were instrumented with different rotary files, namely, ProTaper Universal, ProTaper Next, and HyFlex CM, to the major apical foramen (AF), short AF, and beyond AF. The root apex was stained with 1% methylene blue dye and digital images of apical surface of every tooth were taken and development of dentinal defects was determined by using stereomicroscope. Multinomial logistic regression test was performed to identify influencing factors. Results. Instrumentation with rotary files terminated 2 mm short AF and did not cause any cracks. Significantly less cracks were seen when instrumentation with rotary files terminated 1 mm short apical foramen when compared with the instrumentation terminated at or beyond apical foramen (p < 0.05). Conclusion. ProTaper Universal rotary files caused more dentinal cracks than ProTaper Next and HyFlex CM. Instrumentation short AF reduced the risk of dentinal defects. Hindawi Publishing Corporation 2016 2016-06-29 /pmc/articles/PMC4942666/ /pubmed/27446636 http://dx.doi.org/10.1155/2016/8379865 Text en Copyright © 2016 Fauzia Ashraf et al. https://creativecommons.org/licenses/by/4.0/ This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Research Article
Ashraf, Fauzia
Shankarappa, Pushpa
Misra, Abhinav
Sawhney, Asheesh
Sridevi, Nandamuri
Singh, Anu
A Stereomicroscopic Evaluation of Dentinal Cracks at Different Instrumentation Lengths by Using Different Rotary Files (ProTaper Universal, ProTaper Next, and HyFlex CM): An Ex Vivo Study
title A Stereomicroscopic Evaluation of Dentinal Cracks at Different Instrumentation Lengths by Using Different Rotary Files (ProTaper Universal, ProTaper Next, and HyFlex CM): An Ex Vivo Study
title_full A Stereomicroscopic Evaluation of Dentinal Cracks at Different Instrumentation Lengths by Using Different Rotary Files (ProTaper Universal, ProTaper Next, and HyFlex CM): An Ex Vivo Study
title_fullStr A Stereomicroscopic Evaluation of Dentinal Cracks at Different Instrumentation Lengths by Using Different Rotary Files (ProTaper Universal, ProTaper Next, and HyFlex CM): An Ex Vivo Study
title_full_unstemmed A Stereomicroscopic Evaluation of Dentinal Cracks at Different Instrumentation Lengths by Using Different Rotary Files (ProTaper Universal, ProTaper Next, and HyFlex CM): An Ex Vivo Study
title_short A Stereomicroscopic Evaluation of Dentinal Cracks at Different Instrumentation Lengths by Using Different Rotary Files (ProTaper Universal, ProTaper Next, and HyFlex CM): An Ex Vivo Study
title_sort stereomicroscopic evaluation of dentinal cracks at different instrumentation lengths by using different rotary files (protaper universal, protaper next, and hyflex cm): an ex vivo study
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4942666/
https://www.ncbi.nlm.nih.gov/pubmed/27446636
http://dx.doi.org/10.1155/2016/8379865
work_keys_str_mv AT ashraffauzia astereomicroscopicevaluationofdentinalcracksatdifferentinstrumentationlengthsbyusingdifferentrotaryfilesprotaperuniversalprotapernextandhyflexcmanexvivostudy
AT shankarappapushpa astereomicroscopicevaluationofdentinalcracksatdifferentinstrumentationlengthsbyusingdifferentrotaryfilesprotaperuniversalprotapernextandhyflexcmanexvivostudy
AT misraabhinav astereomicroscopicevaluationofdentinalcracksatdifferentinstrumentationlengthsbyusingdifferentrotaryfilesprotaperuniversalprotapernextandhyflexcmanexvivostudy
AT sawhneyasheesh astereomicroscopicevaluationofdentinalcracksatdifferentinstrumentationlengthsbyusingdifferentrotaryfilesprotaperuniversalprotapernextandhyflexcmanexvivostudy
AT sridevinandamuri astereomicroscopicevaluationofdentinalcracksatdifferentinstrumentationlengthsbyusingdifferentrotaryfilesprotaperuniversalprotapernextandhyflexcmanexvivostudy
AT singhanu astereomicroscopicevaluationofdentinalcracksatdifferentinstrumentationlengthsbyusingdifferentrotaryfilesprotaperuniversalprotapernextandhyflexcmanexvivostudy
AT ashraffauzia stereomicroscopicevaluationofdentinalcracksatdifferentinstrumentationlengthsbyusingdifferentrotaryfilesprotaperuniversalprotapernextandhyflexcmanexvivostudy
AT shankarappapushpa stereomicroscopicevaluationofdentinalcracksatdifferentinstrumentationlengthsbyusingdifferentrotaryfilesprotaperuniversalprotapernextandhyflexcmanexvivostudy
AT misraabhinav stereomicroscopicevaluationofdentinalcracksatdifferentinstrumentationlengthsbyusingdifferentrotaryfilesprotaperuniversalprotapernextandhyflexcmanexvivostudy
AT sawhneyasheesh stereomicroscopicevaluationofdentinalcracksatdifferentinstrumentationlengthsbyusingdifferentrotaryfilesprotaperuniversalprotapernextandhyflexcmanexvivostudy
AT sridevinandamuri stereomicroscopicevaluationofdentinalcracksatdifferentinstrumentationlengthsbyusingdifferentrotaryfilesprotaperuniversalprotapernextandhyflexcmanexvivostudy
AT singhanu stereomicroscopicevaluationofdentinalcracksatdifferentinstrumentationlengthsbyusingdifferentrotaryfilesprotaperuniversalprotapernextandhyflexcmanexvivostudy