Cargando…
Combined 3 Tesla MRI Biomarkers Improve the Differentiation between Benign vs Malignant Single Ring Enhancing Brain Masses
PURPOSE: To evaluate whether the combination of imaging biomarkers obtained by means of different 3 Tesla (3T) Magnetic Resonance Imaging (MRI) advanced techniques can improve the diagnostic accuracy in the differentiation between benign and malignant single ring-enhancing brain masses. MATERIALS AN...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Public Library of Science
2016
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4943588/ https://www.ncbi.nlm.nih.gov/pubmed/27410226 http://dx.doi.org/10.1371/journal.pone.0159047 |
_version_ | 1782442620367142912 |
---|---|
author | Salice, Simone Esposito, Roberto Ciavardelli, Domenico delli Pizzi, Stefano di Bastiano, Rossella Tartaro, Armando |
author_facet | Salice, Simone Esposito, Roberto Ciavardelli, Domenico delli Pizzi, Stefano di Bastiano, Rossella Tartaro, Armando |
author_sort | Salice, Simone |
collection | PubMed |
description | PURPOSE: To evaluate whether the combination of imaging biomarkers obtained by means of different 3 Tesla (3T) Magnetic Resonance Imaging (MRI) advanced techniques can improve the diagnostic accuracy in the differentiation between benign and malignant single ring-enhancing brain masses. MATERIALS AND METHODS: 14 patients presenting at conventional 3T MRI single brain mass with similar appearance as regard ring enhancement, presence of peri-lesional edema and absence of hemorrhage signs were included in the study. All lesions were histologically proven: 5 pyogenic abscesses, 6 glioblastomas, and 3 metastases. MRI was performed at 3 Tesla and included Diffusion Weighted Imaging (DWI), Dynamic Susceptibility Contrast -Perfusion Weighted Imaging (DSC-PWI), Magnetic Resonance Spectroscopy (MRS), and Diffusion Tensor Imaging (DTI). Imaging biomarkers derived by those advanced techniques [Cerebral Blood Flow (CBF), relative Cerebral Blood Volume (rCBV), relative Main Transit Time (rMTT), Choline (Cho), Creatine (Cr), Succinate, N-Acetyl Aspartate (NAA), Lactate (Lac), Lipids, relative Apparent Diffusion Coefficient (rADC), and Fractional Anisotropy (FA)] were detected by two experienced neuroradiologists in joint session in 4 areas: Internal Cavity (IC), Ring Enhancement (RE), Peri-Lesional edema (PL), and Contralateral Normal Appearing White Matter (CNAWM). Significant differences between benign (n = 5) and malignant (n = 9) ring enhancing lesions were tested with Mann-Withney U test. The diagnostic accuracy of MRI biomarkers taken alone and MRI biomarkers ratios were tested with Receiver Operating Characteristic (ROC) analysis with an Area Under the Curve (AUC) ≥ 0.9 indicating a very good diagnostic accuracy of the variable. RESULTS: Five MRI biomarker ratios achieved excellent accuracy: IC-rADC/PL-NAA (AUC = 1), IC-rADC/IC-FA (AUC = 0.978), RE-rCBV/RE-FA (AUC = 0.933), IC-rADC/RE-FA (AUC = 0.911), and IC-rADC/PL-FA (AUC = 0.911). Only IC-rADC achieved a very good diagnostic accuracy (AUC = 0.909) among MRI biomarkers taken alone. CONCLUSION: Although the major limitation of the study was the small sample size, preliminary results seem to suggest that combination of multiple 3T MRI biomarkers is a feasible approach to MRI biomarkers in order to improve diagnostic accuracy in the differentiation between benign and malignant single ring enhancing brain masses. Further studies in larger cohorts are needed to reach definitive conclusions. |
format | Online Article Text |
id | pubmed-4943588 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2016 |
publisher | Public Library of Science |
record_format | MEDLINE/PubMed |
spelling | pubmed-49435882016-08-01 Combined 3 Tesla MRI Biomarkers Improve the Differentiation between Benign vs Malignant Single Ring Enhancing Brain Masses Salice, Simone Esposito, Roberto Ciavardelli, Domenico delli Pizzi, Stefano di Bastiano, Rossella Tartaro, Armando PLoS One Research Article PURPOSE: To evaluate whether the combination of imaging biomarkers obtained by means of different 3 Tesla (3T) Magnetic Resonance Imaging (MRI) advanced techniques can improve the diagnostic accuracy in the differentiation between benign and malignant single ring-enhancing brain masses. MATERIALS AND METHODS: 14 patients presenting at conventional 3T MRI single brain mass with similar appearance as regard ring enhancement, presence of peri-lesional edema and absence of hemorrhage signs were included in the study. All lesions were histologically proven: 5 pyogenic abscesses, 6 glioblastomas, and 3 metastases. MRI was performed at 3 Tesla and included Diffusion Weighted Imaging (DWI), Dynamic Susceptibility Contrast -Perfusion Weighted Imaging (DSC-PWI), Magnetic Resonance Spectroscopy (MRS), and Diffusion Tensor Imaging (DTI). Imaging biomarkers derived by those advanced techniques [Cerebral Blood Flow (CBF), relative Cerebral Blood Volume (rCBV), relative Main Transit Time (rMTT), Choline (Cho), Creatine (Cr), Succinate, N-Acetyl Aspartate (NAA), Lactate (Lac), Lipids, relative Apparent Diffusion Coefficient (rADC), and Fractional Anisotropy (FA)] were detected by two experienced neuroradiologists in joint session in 4 areas: Internal Cavity (IC), Ring Enhancement (RE), Peri-Lesional edema (PL), and Contralateral Normal Appearing White Matter (CNAWM). Significant differences between benign (n = 5) and malignant (n = 9) ring enhancing lesions were tested with Mann-Withney U test. The diagnostic accuracy of MRI biomarkers taken alone and MRI biomarkers ratios were tested with Receiver Operating Characteristic (ROC) analysis with an Area Under the Curve (AUC) ≥ 0.9 indicating a very good diagnostic accuracy of the variable. RESULTS: Five MRI biomarker ratios achieved excellent accuracy: IC-rADC/PL-NAA (AUC = 1), IC-rADC/IC-FA (AUC = 0.978), RE-rCBV/RE-FA (AUC = 0.933), IC-rADC/RE-FA (AUC = 0.911), and IC-rADC/PL-FA (AUC = 0.911). Only IC-rADC achieved a very good diagnostic accuracy (AUC = 0.909) among MRI biomarkers taken alone. CONCLUSION: Although the major limitation of the study was the small sample size, preliminary results seem to suggest that combination of multiple 3T MRI biomarkers is a feasible approach to MRI biomarkers in order to improve diagnostic accuracy in the differentiation between benign and malignant single ring enhancing brain masses. Further studies in larger cohorts are needed to reach definitive conclusions. Public Library of Science 2016-07-13 /pmc/articles/PMC4943588/ /pubmed/27410226 http://dx.doi.org/10.1371/journal.pone.0159047 Text en © 2016 Salice et al http://creativecommons.org/licenses/by/4.0/ This is an open access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/4.0/) , which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited. |
spellingShingle | Research Article Salice, Simone Esposito, Roberto Ciavardelli, Domenico delli Pizzi, Stefano di Bastiano, Rossella Tartaro, Armando Combined 3 Tesla MRI Biomarkers Improve the Differentiation between Benign vs Malignant Single Ring Enhancing Brain Masses |
title | Combined 3 Tesla MRI Biomarkers Improve the Differentiation between Benign vs Malignant Single Ring Enhancing Brain Masses |
title_full | Combined 3 Tesla MRI Biomarkers Improve the Differentiation between Benign vs Malignant Single Ring Enhancing Brain Masses |
title_fullStr | Combined 3 Tesla MRI Biomarkers Improve the Differentiation between Benign vs Malignant Single Ring Enhancing Brain Masses |
title_full_unstemmed | Combined 3 Tesla MRI Biomarkers Improve the Differentiation between Benign vs Malignant Single Ring Enhancing Brain Masses |
title_short | Combined 3 Tesla MRI Biomarkers Improve the Differentiation between Benign vs Malignant Single Ring Enhancing Brain Masses |
title_sort | combined 3 tesla mri biomarkers improve the differentiation between benign vs malignant single ring enhancing brain masses |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4943588/ https://www.ncbi.nlm.nih.gov/pubmed/27410226 http://dx.doi.org/10.1371/journal.pone.0159047 |
work_keys_str_mv | AT salicesimone combined3teslamribiomarkersimprovethedifferentiationbetweenbenignvsmalignantsingleringenhancingbrainmasses AT espositoroberto combined3teslamribiomarkersimprovethedifferentiationbetweenbenignvsmalignantsingleringenhancingbrainmasses AT ciavardellidomenico combined3teslamribiomarkersimprovethedifferentiationbetweenbenignvsmalignantsingleringenhancingbrainmasses AT dellipizzistefano combined3teslamribiomarkersimprovethedifferentiationbetweenbenignvsmalignantsingleringenhancingbrainmasses AT dibastianorossella combined3teslamribiomarkersimprovethedifferentiationbetweenbenignvsmalignantsingleringenhancingbrainmasses AT tartaroarmando combined3teslamribiomarkersimprovethedifferentiationbetweenbenignvsmalignantsingleringenhancingbrainmasses |