Calibration of Voltage Transformers and High- Voltage Capacitors at NIST
The National Institute of Standards and Technology (NIST) calibration service for voltage transformers and high-voltage capacitors is described. The service for voltage transformers provides measurements of ratio correction factors and phase angles at primary voltages up to 170 kV and secondary volt...
Autor principal: | |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
[Gaithersburg, MD] : U.S. Dept. of Commerce, National Institute of Standards and Technology
1989
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4943747/ https://www.ncbi.nlm.nih.gov/pubmed/28053409 http://dx.doi.org/10.6028/jres.094.019 |
_version_ | 1782442642934595584 |
---|---|
author | Anderson, William E. |
author_facet | Anderson, William E. |
author_sort | Anderson, William E. |
collection | PubMed |
description | The National Institute of Standards and Technology (NIST) calibration service for voltage transformers and high-voltage capacitors is described. The service for voltage transformers provides measurements of ratio correction factors and phase angles at primary voltages up to 170 kV and secondary voltages as low as 10 V at 60 Hz. Calibrations at frequencies from 50–400 Hz are available over a more limited voltage range. The service for high-voltage capacitors provides measurements of capacitance and dissipation factor at applied voltages ranging from 100 V to 170 kV at 60 Hz depending on the nominal capacitance. Calibrations over a reduced voltage range at other frequencies are also available. As in the case with voltage transformers, these voltage constraints are determined by the facilities at NIST. |
format | Online Article Text |
id | pubmed-4943747 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 1989 |
publisher | [Gaithersburg, MD] : U.S. Dept. of Commerce, National Institute of Standards and Technology |
record_format | MEDLINE/PubMed |
spelling | pubmed-49437472017-01-04 Calibration of Voltage Transformers and High- Voltage Capacitors at NIST Anderson, William E. J Res Natl Inst Stand Technol Article The National Institute of Standards and Technology (NIST) calibration service for voltage transformers and high-voltage capacitors is described. The service for voltage transformers provides measurements of ratio correction factors and phase angles at primary voltages up to 170 kV and secondary voltages as low as 10 V at 60 Hz. Calibrations at frequencies from 50–400 Hz are available over a more limited voltage range. The service for high-voltage capacitors provides measurements of capacitance and dissipation factor at applied voltages ranging from 100 V to 170 kV at 60 Hz depending on the nominal capacitance. Calibrations over a reduced voltage range at other frequencies are also available. As in the case with voltage transformers, these voltage constraints are determined by the facilities at NIST. [Gaithersburg, MD] : U.S. Dept. of Commerce, National Institute of Standards and Technology 1989 /pmc/articles/PMC4943747/ /pubmed/28053409 http://dx.doi.org/10.6028/jres.094.019 Text en https://creativecommons.org/publicdomain/zero/1.0/ The Journal of Research of the National Institute of Standards and Technology is a publication of the U.S. Government. The papers are in the public domain and are not subject to copyright in the United States. Articles from J Res may contain photographs or illustrations copyrighted by other commercial organizations or individuals that may not be used without obtaining prior approval from the holder of the copyright. |
spellingShingle | Article Anderson, William E. Calibration of Voltage Transformers and High- Voltage Capacitors at NIST |
title | Calibration of Voltage Transformers and High- Voltage Capacitors at NIST |
title_full | Calibration of Voltage Transformers and High- Voltage Capacitors at NIST |
title_fullStr | Calibration of Voltage Transformers and High- Voltage Capacitors at NIST |
title_full_unstemmed | Calibration of Voltage Transformers and High- Voltage Capacitors at NIST |
title_short | Calibration of Voltage Transformers and High- Voltage Capacitors at NIST |
title_sort | calibration of voltage transformers and high- voltage capacitors at nist |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4943747/ https://www.ncbi.nlm.nih.gov/pubmed/28053409 http://dx.doi.org/10.6028/jres.094.019 |
work_keys_str_mv | AT andersonwilliame calibrationofvoltagetransformersandhighvoltagecapacitorsatnist |