Cargando…

Body surface infrared thermometry in patients with central venous cateter-related infections

OBJECTIVE: To evaluate if body surface temperature close to the central venous catheter insertion area is different when patients develop catheter-related bloodstream infections. METHODS: Observational cross-sectional study. Using a non-contact infrared thermometer, 3 consecutive measurements of bod...

Descripción completa

Detalles Bibliográficos
Autores principales: Silvah, José Henrique, de Lima, Cristiane Maria Mártires, de Unamuno, Maria do Rosário Del Lama, Schetino, Marco Antônio Alves, Schetino, Luana Pereira Leite, Fassini, Priscila Giácomo, Brandão, Camila Fernanda Costa e Cunha Moraes, Basile, Anibal, da Cunha, Selma Freire Carvalho, Marchini, Julio Sergio
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Instituto de Ensino e Pesquisa Albert Einstein 2015
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4943780/
https://www.ncbi.nlm.nih.gov/pubmed/26466058
http://dx.doi.org/10.1590/S1679-45082015AO3397
_version_ 1782442647266263040
author Silvah, José Henrique
de Lima, Cristiane Maria Mártires
de Unamuno, Maria do Rosário Del Lama
Schetino, Marco Antônio Alves
Schetino, Luana Pereira Leite
Fassini, Priscila Giácomo
Brandão, Camila Fernanda Costa e Cunha Moraes
Basile, Anibal
da Cunha, Selma Freire Carvalho
Marchini, Julio Sergio
author_facet Silvah, José Henrique
de Lima, Cristiane Maria Mártires
de Unamuno, Maria do Rosário Del Lama
Schetino, Marco Antônio Alves
Schetino, Luana Pereira Leite
Fassini, Priscila Giácomo
Brandão, Camila Fernanda Costa e Cunha Moraes
Basile, Anibal
da Cunha, Selma Freire Carvalho
Marchini, Julio Sergio
author_sort Silvah, José Henrique
collection PubMed
description OBJECTIVE: To evaluate if body surface temperature close to the central venous catheter insertion area is different when patients develop catheter-related bloodstream infections. METHODS: Observational cross-sectional study. Using a non-contact infrared thermometer, 3 consecutive measurements of body surface temperature were collected from 39 patients with central venous catheter on the following sites: nearby the catheter insertion area or totally implantable catheter reservoir, the equivalent contralateral region (without catheter), and forehead of the same subject. RESULTS: A total of 323 observations were collected. Respectively, both in male and female patients, disregarding the occurrence of infection, the mean temperature on the catheter area minus that on the contralateral region (mean ± standard deviation: -0.3±0.6°C versus -0.2±0.5ºC; p=0.36), and the mean temperature on the catheter area minus that on the forehead (mean ± standard deviation: -0.2±0.5°C versus -0.1±0.5ºC; p=0.3) resulted in negative values. Moreover, in infected patients, higher values were obtained on the catheter area (95%CI: 36.6-37.5ºC versus 36.3-36.5ºC; p<0.01) and by temperature subtractions: catheter area minus contralateral region (95%CI: -0.17 - +0.33ºC versus -0.33 - -0.20ºC; p=0.02) and catheter area minus forehead (95%CI: -0.02 - +0.55ºC versus -0.22 - -0.10ºC; p<0.01). CONCLUSION: Using a non-contact infrared thermometer, patients with catheter-related bloodstream infections had higher temperature values both around catheter insertion area and in the subtraction of the temperatures on the contralateral and forehead regions from those on the catheter area.
format Online
Article
Text
id pubmed-4943780
institution National Center for Biotechnology Information
language English
publishDate 2015
publisher Instituto de Ensino e Pesquisa Albert Einstein
record_format MEDLINE/PubMed
spelling pubmed-49437802016-08-10 Body surface infrared thermometry in patients with central venous cateter-related infections Silvah, José Henrique de Lima, Cristiane Maria Mártires de Unamuno, Maria do Rosário Del Lama Schetino, Marco Antônio Alves Schetino, Luana Pereira Leite Fassini, Priscila Giácomo Brandão, Camila Fernanda Costa e Cunha Moraes Basile, Anibal da Cunha, Selma Freire Carvalho Marchini, Julio Sergio Einstein (Sao Paulo) Original Article OBJECTIVE: To evaluate if body surface temperature close to the central venous catheter insertion area is different when patients develop catheter-related bloodstream infections. METHODS: Observational cross-sectional study. Using a non-contact infrared thermometer, 3 consecutive measurements of body surface temperature were collected from 39 patients with central venous catheter on the following sites: nearby the catheter insertion area or totally implantable catheter reservoir, the equivalent contralateral region (without catheter), and forehead of the same subject. RESULTS: A total of 323 observations were collected. Respectively, both in male and female patients, disregarding the occurrence of infection, the mean temperature on the catheter area minus that on the contralateral region (mean ± standard deviation: -0.3±0.6°C versus -0.2±0.5ºC; p=0.36), and the mean temperature on the catheter area minus that on the forehead (mean ± standard deviation: -0.2±0.5°C versus -0.1±0.5ºC; p=0.3) resulted in negative values. Moreover, in infected patients, higher values were obtained on the catheter area (95%CI: 36.6-37.5ºC versus 36.3-36.5ºC; p<0.01) and by temperature subtractions: catheter area minus contralateral region (95%CI: -0.17 - +0.33ºC versus -0.33 - -0.20ºC; p=0.02) and catheter area minus forehead (95%CI: -0.02 - +0.55ºC versus -0.22 - -0.10ºC; p<0.01). CONCLUSION: Using a non-contact infrared thermometer, patients with catheter-related bloodstream infections had higher temperature values both around catheter insertion area and in the subtraction of the temperatures on the contralateral and forehead regions from those on the catheter area. Instituto de Ensino e Pesquisa Albert Einstein 2015 /pmc/articles/PMC4943780/ /pubmed/26466058 http://dx.doi.org/10.1590/S1679-45082015AO3397 Text en http://creativecommons.org/licenses/by/4.0/ This is an Open Access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Original Article
Silvah, José Henrique
de Lima, Cristiane Maria Mártires
de Unamuno, Maria do Rosário Del Lama
Schetino, Marco Antônio Alves
Schetino, Luana Pereira Leite
Fassini, Priscila Giácomo
Brandão, Camila Fernanda Costa e Cunha Moraes
Basile, Anibal
da Cunha, Selma Freire Carvalho
Marchini, Julio Sergio
Body surface infrared thermometry in patients with central venous cateter-related infections
title Body surface infrared thermometry in patients with central venous cateter-related infections
title_full Body surface infrared thermometry in patients with central venous cateter-related infections
title_fullStr Body surface infrared thermometry in patients with central venous cateter-related infections
title_full_unstemmed Body surface infrared thermometry in patients with central venous cateter-related infections
title_short Body surface infrared thermometry in patients with central venous cateter-related infections
title_sort body surface infrared thermometry in patients with central venous cateter-related infections
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4943780/
https://www.ncbi.nlm.nih.gov/pubmed/26466058
http://dx.doi.org/10.1590/S1679-45082015AO3397
work_keys_str_mv AT silvahjosehenrique bodysurfaceinfraredthermometryinpatientswithcentralvenouscateterrelatedinfections
AT delimacristianemariamartires bodysurfaceinfraredthermometryinpatientswithcentralvenouscateterrelatedinfections
AT deunamunomariadorosariodellama bodysurfaceinfraredthermometryinpatientswithcentralvenouscateterrelatedinfections
AT schetinomarcoantonioalves bodysurfaceinfraredthermometryinpatientswithcentralvenouscateterrelatedinfections
AT schetinoluanapereiraleite bodysurfaceinfraredthermometryinpatientswithcentralvenouscateterrelatedinfections
AT fassinipriscilagiacomo bodysurfaceinfraredthermometryinpatientswithcentralvenouscateterrelatedinfections
AT brandaocamilafernandacostaecunhamoraes bodysurfaceinfraredthermometryinpatientswithcentralvenouscateterrelatedinfections
AT basileanibal bodysurfaceinfraredthermometryinpatientswithcentralvenouscateterrelatedinfections
AT dacunhaselmafreirecarvalho bodysurfaceinfraredthermometryinpatientswithcentralvenouscateterrelatedinfections
AT marchinijuliosergio bodysurfaceinfraredthermometryinpatientswithcentralvenouscateterrelatedinfections