Cargando…

Comparison of Result Times Between Urine and Whole Blood Point-of-care Pregnancy Testing

INTRODUCTION: Point-of-care (POC) pregnancy testing is commonly performed in the emergency department (ED). One prior study demonstrated equivalent accuracy between urine and whole blood for one common brand of POC pregnancy testing. Our study sought to determine the difference in result times when...

Descripción completa

Detalles Bibliográficos
Autores principales: Gottlieb, Michael, Wnek, Kristopher, Moskoff, Jordan, Christian, Errick, Bailitz, John
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Department of Emergency Medicine, University of California, Irvine School of Medicine 2016
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4944801/
https://www.ncbi.nlm.nih.gov/pubmed/27429695
http://dx.doi.org/10.5811/westjem.2016.5.29989
_version_ 1782442815684345856
author Gottlieb, Michael
Wnek, Kristopher
Moskoff, Jordan
Christian, Errick
Bailitz, John
author_facet Gottlieb, Michael
Wnek, Kristopher
Moskoff, Jordan
Christian, Errick
Bailitz, John
author_sort Gottlieb, Michael
collection PubMed
description INTRODUCTION: Point-of-care (POC) pregnancy testing is commonly performed in the emergency department (ED). One prior study demonstrated equivalent accuracy between urine and whole blood for one common brand of POC pregnancy testing. Our study sought to determine the difference in result times when comparing whole blood versus urine for the same brand of POC pregnancy testing. METHODS: We conducted a prospective, observational study at an urban, academic, tertiary care hospital comparing the turnaround time between order and result for urine and whole blood pregnancy tests collected according to standard protocol without intervention from the investigators. After the blood was collected, the nurse would place three drops onto a Beckman Coulter ICON 25 Rapid HCG bedside pregnancy test and set a timer for 10 minutes. At the end of the 10 minutes, the result and time were recorded on an encoded data sheet and not used clinically. The same make and model analyzer was also used for urine tests in the lab located within the ED. The primary outcome was the difference in mean turnaround time between whole blood in the ED and urine testing in the adjacent lab results. Concordance between samples was assessed as a secondary outcome. RESULTS: 265 total patients were included in the study. The use of whole blood resulted in a mean time savings of 21 minutes (95% CI 16–25 minutes) when compared with urine (p<0.001). There was 99.6% concordance between results, with one false negative urine specimen with a quantitative HCG level of 81 mIU/L. CONCLUSION: Our results suggest that the use of whole blood in place of urine for bedside pregnancy testing may reduce the total result turnaround time without significant changes in accuracy in this single-center study.
format Online
Article
Text
id pubmed-4944801
institution National Center for Biotechnology Information
language English
publishDate 2016
publisher Department of Emergency Medicine, University of California, Irvine School of Medicine
record_format MEDLINE/PubMed
spelling pubmed-49448012016-07-15 Comparison of Result Times Between Urine and Whole Blood Point-of-care Pregnancy Testing Gottlieb, Michael Wnek, Kristopher Moskoff, Jordan Christian, Errick Bailitz, John West J Emerg Med Emergency Department Operations INTRODUCTION: Point-of-care (POC) pregnancy testing is commonly performed in the emergency department (ED). One prior study demonstrated equivalent accuracy between urine and whole blood for one common brand of POC pregnancy testing. Our study sought to determine the difference in result times when comparing whole blood versus urine for the same brand of POC pregnancy testing. METHODS: We conducted a prospective, observational study at an urban, academic, tertiary care hospital comparing the turnaround time between order and result for urine and whole blood pregnancy tests collected according to standard protocol without intervention from the investigators. After the blood was collected, the nurse would place three drops onto a Beckman Coulter ICON 25 Rapid HCG bedside pregnancy test and set a timer for 10 minutes. At the end of the 10 minutes, the result and time were recorded on an encoded data sheet and not used clinically. The same make and model analyzer was also used for urine tests in the lab located within the ED. The primary outcome was the difference in mean turnaround time between whole blood in the ED and urine testing in the adjacent lab results. Concordance between samples was assessed as a secondary outcome. RESULTS: 265 total patients were included in the study. The use of whole blood resulted in a mean time savings of 21 minutes (95% CI 16–25 minutes) when compared with urine (p<0.001). There was 99.6% concordance between results, with one false negative urine specimen with a quantitative HCG level of 81 mIU/L. CONCLUSION: Our results suggest that the use of whole blood in place of urine for bedside pregnancy testing may reduce the total result turnaround time without significant changes in accuracy in this single-center study. Department of Emergency Medicine, University of California, Irvine School of Medicine 2016-07 2016-06-22 /pmc/articles/PMC4944801/ /pubmed/27429695 http://dx.doi.org/10.5811/westjem.2016.5.29989 Text en © 2016 Gottlieb et al. http://creativecommons.org/licenses/by/4.0/ This is an open access article distributed in accordance with the terms of the Creative Commons Attribution (CC BY 4.0) License. See: http://creativecommons.org/licenses/by/4.0/
spellingShingle Emergency Department Operations
Gottlieb, Michael
Wnek, Kristopher
Moskoff, Jordan
Christian, Errick
Bailitz, John
Comparison of Result Times Between Urine and Whole Blood Point-of-care Pregnancy Testing
title Comparison of Result Times Between Urine and Whole Blood Point-of-care Pregnancy Testing
title_full Comparison of Result Times Between Urine and Whole Blood Point-of-care Pregnancy Testing
title_fullStr Comparison of Result Times Between Urine and Whole Blood Point-of-care Pregnancy Testing
title_full_unstemmed Comparison of Result Times Between Urine and Whole Blood Point-of-care Pregnancy Testing
title_short Comparison of Result Times Between Urine and Whole Blood Point-of-care Pregnancy Testing
title_sort comparison of result times between urine and whole blood point-of-care pregnancy testing
topic Emergency Department Operations
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4944801/
https://www.ncbi.nlm.nih.gov/pubmed/27429695
http://dx.doi.org/10.5811/westjem.2016.5.29989
work_keys_str_mv AT gottliebmichael comparisonofresulttimesbetweenurineandwholebloodpointofcarepregnancytesting
AT wnekkristopher comparisonofresulttimesbetweenurineandwholebloodpointofcarepregnancytesting
AT moskoffjordan comparisonofresulttimesbetweenurineandwholebloodpointofcarepregnancytesting
AT christianerrick comparisonofresulttimesbetweenurineandwholebloodpointofcarepregnancytesting
AT bailitzjohn comparisonofresulttimesbetweenurineandwholebloodpointofcarepregnancytesting