Cargando…

Two-port laparoscopic appendectomy with the help of a needle grasper: better cosmetic results and fewer trocars than conventional laparoscopic appendectomy

INTRODUCTION: The two-port laparoscopic appendectomy technique (TPLA) lays between the conventional three-port trocar procedure and single-port laparoscopic appendectomy surgery. During TPLA, the appendix is suspended with stitches, resulting in perforation risk and difficulty in exploration. AIM: W...

Descripción completa

Detalles Bibliográficos
Autores principales: Donmez, Turgut, Sunamak, Oguzhan, Ferahman, Sina, Uludag, Server Sezgin, Yildirim, Dogan, Hut, Adnan
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Termedia Publishing House 2016
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4945612/
https://www.ncbi.nlm.nih.gov/pubmed/27458491
http://dx.doi.org/10.5114/wiitm.2016.60504
_version_ 1782442895056306176
author Donmez, Turgut
Sunamak, Oguzhan
Ferahman, Sina
Uludag, Server Sezgin
Yildirim, Dogan
Hut, Adnan
author_facet Donmez, Turgut
Sunamak, Oguzhan
Ferahman, Sina
Uludag, Server Sezgin
Yildirim, Dogan
Hut, Adnan
author_sort Donmez, Turgut
collection PubMed
description INTRODUCTION: The two-port laparoscopic appendectomy technique (TPLA) lays between the conventional three-port trocar procedure and single-port laparoscopic appendectomy surgery. During TPLA, the appendix is suspended with stitches, resulting in perforation risk and difficulty in exploration. AIM: We used a needle grasper in TPLA to hang and manipulate the appendix. MATERIAL AND METHODS: Thirty-four patients (10 female, 24 male) who underwent TPLA between February 2015 and November 2015 were analyzed retrospectively for patient demographics, duration of operation, laparotomy or conventional laparoscopy necessity, drain use, complications, and hospital stay periods. The needle grasper was inserted at the right under the abdominal quadrant (McBurney point) without an incision to hang and manipulate the appendix. RESULTS: The mean age was 25.19 ±8.464 years; the mean body mass index (BMI) was 23.50 ±3.246 kg/m(2). ASA scores were 1 and 2. The operations were completed without any additional trocar in 34 patients. The mean operation time was 57.03 ±3.814 min. There were no intraoperative complications in any patients. Three patients required a drain; all were discharged after drain removal. Thirty-one patients were discharged on the 1(st) postoperative day; three patients with drains were discharged on the 2(nd) day. The mean hospital stay period was 1.18 ±0.535 days. CONCLUSIONS: Using the needle grasper, the appendix was held and suspended and the mesoappendix was cauterized and skeletonized successfully in TPLA. Inserting a needle grasper into the abdominal cavity at the McBurney point to manipulate the appendix helps and does not leave a visible scar.
format Online
Article
Text
id pubmed-4945612
institution National Center for Biotechnology Information
language English
publishDate 2016
publisher Termedia Publishing House
record_format MEDLINE/PubMed
spelling pubmed-49456122016-07-25 Two-port laparoscopic appendectomy with the help of a needle grasper: better cosmetic results and fewer trocars than conventional laparoscopic appendectomy Donmez, Turgut Sunamak, Oguzhan Ferahman, Sina Uludag, Server Sezgin Yildirim, Dogan Hut, Adnan Wideochir Inne Tech Maloinwazyjne Original Paper INTRODUCTION: The two-port laparoscopic appendectomy technique (TPLA) lays between the conventional three-port trocar procedure and single-port laparoscopic appendectomy surgery. During TPLA, the appendix is suspended with stitches, resulting in perforation risk and difficulty in exploration. AIM: We used a needle grasper in TPLA to hang and manipulate the appendix. MATERIAL AND METHODS: Thirty-four patients (10 female, 24 male) who underwent TPLA between February 2015 and November 2015 were analyzed retrospectively for patient demographics, duration of operation, laparotomy or conventional laparoscopy necessity, drain use, complications, and hospital stay periods. The needle grasper was inserted at the right under the abdominal quadrant (McBurney point) without an incision to hang and manipulate the appendix. RESULTS: The mean age was 25.19 ±8.464 years; the mean body mass index (BMI) was 23.50 ±3.246 kg/m(2). ASA scores were 1 and 2. The operations were completed without any additional trocar in 34 patients. The mean operation time was 57.03 ±3.814 min. There were no intraoperative complications in any patients. Three patients required a drain; all were discharged after drain removal. Thirty-one patients were discharged on the 1(st) postoperative day; three patients with drains were discharged on the 2(nd) day. The mean hospital stay period was 1.18 ±0.535 days. CONCLUSIONS: Using the needle grasper, the appendix was held and suspended and the mesoappendix was cauterized and skeletonized successfully in TPLA. Inserting a needle grasper into the abdominal cavity at the McBurney point to manipulate the appendix helps and does not leave a visible scar. Termedia Publishing House 2016-06-13 2016-06 /pmc/articles/PMC4945612/ /pubmed/27458491 http://dx.doi.org/10.5114/wiitm.2016.60504 Text en Copyright © 2016 Fundacja Videochirurgii http://creativecommons.org/licenses/by-nc-sa/4.0/ This is an Open Access article distributed under the terms of the Creative Commons Attribution-NonCommercial-ShareAlike 4.0 International (CC BY-NC-SA 4.0) License, allowing third parties to copy and redistribute the material in any medium or format and to remix, transform, and build upon the material, provided the original work is properly cited and states its license.
spellingShingle Original Paper
Donmez, Turgut
Sunamak, Oguzhan
Ferahman, Sina
Uludag, Server Sezgin
Yildirim, Dogan
Hut, Adnan
Two-port laparoscopic appendectomy with the help of a needle grasper: better cosmetic results and fewer trocars than conventional laparoscopic appendectomy
title Two-port laparoscopic appendectomy with the help of a needle grasper: better cosmetic results and fewer trocars than conventional laparoscopic appendectomy
title_full Two-port laparoscopic appendectomy with the help of a needle grasper: better cosmetic results and fewer trocars than conventional laparoscopic appendectomy
title_fullStr Two-port laparoscopic appendectomy with the help of a needle grasper: better cosmetic results and fewer trocars than conventional laparoscopic appendectomy
title_full_unstemmed Two-port laparoscopic appendectomy with the help of a needle grasper: better cosmetic results and fewer trocars than conventional laparoscopic appendectomy
title_short Two-port laparoscopic appendectomy with the help of a needle grasper: better cosmetic results and fewer trocars than conventional laparoscopic appendectomy
title_sort two-port laparoscopic appendectomy with the help of a needle grasper: better cosmetic results and fewer trocars than conventional laparoscopic appendectomy
topic Original Paper
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4945612/
https://www.ncbi.nlm.nih.gov/pubmed/27458491
http://dx.doi.org/10.5114/wiitm.2016.60504
work_keys_str_mv AT donmezturgut twoportlaparoscopicappendectomywiththehelpofaneedlegrasperbettercosmeticresultsandfewertrocarsthanconventionallaparoscopicappendectomy
AT sunamakoguzhan twoportlaparoscopicappendectomywiththehelpofaneedlegrasperbettercosmeticresultsandfewertrocarsthanconventionallaparoscopicappendectomy
AT ferahmansina twoportlaparoscopicappendectomywiththehelpofaneedlegrasperbettercosmeticresultsandfewertrocarsthanconventionallaparoscopicappendectomy
AT uludagserversezgin twoportlaparoscopicappendectomywiththehelpofaneedlegrasperbettercosmeticresultsandfewertrocarsthanconventionallaparoscopicappendectomy
AT yildirimdogan twoportlaparoscopicappendectomywiththehelpofaneedlegrasperbettercosmeticresultsandfewertrocarsthanconventionallaparoscopicappendectomy
AT hutadnan twoportlaparoscopicappendectomywiththehelpofaneedlegrasperbettercosmeticresultsandfewertrocarsthanconventionallaparoscopicappendectomy