Cargando…

Role of Computer Aided Diagnosis (CAD) in the detection of pulmonary nodules on 64 row multi detector computed tomography

AIMS AND OBJECTIVES: To determine the overall performance of an existing CAD algorithm with thin-section computed tomography (CT) in the detection of pulmonary nodules and to evaluate detection sensitivity at a varying range of nodule density, size, and location. MATERIALS AND METHODS: A cross-secti...

Descripción completa

Detalles Bibliográficos
Autores principales: Prakashini, K, Babu, Satish, Rajgopal, KV, Kokila, K Raja
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Medknow Publications & Media Pvt Ltd 2016
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4948226/
https://www.ncbi.nlm.nih.gov/pubmed/27578931
http://dx.doi.org/10.4103/0970-2113.184872
_version_ 1782443296406110208
author Prakashini, K
Babu, Satish
Rajgopal, KV
Kokila, K Raja
author_facet Prakashini, K
Babu, Satish
Rajgopal, KV
Kokila, K Raja
author_sort Prakashini, K
collection PubMed
description AIMS AND OBJECTIVES: To determine the overall performance of an existing CAD algorithm with thin-section computed tomography (CT) in the detection of pulmonary nodules and to evaluate detection sensitivity at a varying range of nodule density, size, and location. MATERIALS AND METHODS: A cross-sectional prospective study was conducted on 20 patients with 322 suspected nodules who underwent diagnostic chest imaging using 64-row multi-detector CT. The examinations were evaluated on reconstructed images of 1.4 mm thickness and 0.7 mm interval. Detection of pulmonary nodules, initially by a radiologist of 2 years experience (RAD) and later by CAD lung nodule software was assessed. Then, CAD nodule candidates were accepted or rejected accordingly. Detected nodules were classified based on their size, density, and location. The performance of the RAD and CAD system was compared with the gold standard that is true nodules confirmed by consensus of senior RAD and CAD together. The overall sensitivity and false-positive (FP) rate of CAD software was calculated. OBSERVATIONS AND RESULTS: Of the 322 suspected nodules, 221 were classified as true nodules on the consensus of senior RAD and CAD together. Of the true nodules, the RAD detected 206 (93.2%) and 202 (91.4%) by the CAD. CAD and RAD together picked up more number of nodules than either CAD or RAD alone. Overall sensitivity for nodule detection with the CAD program was 91.4%, and FP detection per patient was 5.5%. The CAD showed comparatively higher sensitivity for nodules of size 4–10 mm (93.4%) and nodules in hilar (100%) and central (96.5%) location when compared to RAD's performance. CONCLUSION: CAD performance was high in detecting pulmonary nodules including the small size and low-density nodules. CAD even with relatively high FP rate, assists and improves RAD's performance as a second reader, especially for nodules located in the central and hilar region and for small nodules by saving RADs time.
format Online
Article
Text
id pubmed-4948226
institution National Center for Biotechnology Information
language English
publishDate 2016
publisher Medknow Publications & Media Pvt Ltd
record_format MEDLINE/PubMed
spelling pubmed-49482262016-08-30 Role of Computer Aided Diagnosis (CAD) in the detection of pulmonary nodules on 64 row multi detector computed tomography Prakashini, K Babu, Satish Rajgopal, KV Kokila, K Raja Lung India Original Article AIMS AND OBJECTIVES: To determine the overall performance of an existing CAD algorithm with thin-section computed tomography (CT) in the detection of pulmonary nodules and to evaluate detection sensitivity at a varying range of nodule density, size, and location. MATERIALS AND METHODS: A cross-sectional prospective study was conducted on 20 patients with 322 suspected nodules who underwent diagnostic chest imaging using 64-row multi-detector CT. The examinations were evaluated on reconstructed images of 1.4 mm thickness and 0.7 mm interval. Detection of pulmonary nodules, initially by a radiologist of 2 years experience (RAD) and later by CAD lung nodule software was assessed. Then, CAD nodule candidates were accepted or rejected accordingly. Detected nodules were classified based on their size, density, and location. The performance of the RAD and CAD system was compared with the gold standard that is true nodules confirmed by consensus of senior RAD and CAD together. The overall sensitivity and false-positive (FP) rate of CAD software was calculated. OBSERVATIONS AND RESULTS: Of the 322 suspected nodules, 221 were classified as true nodules on the consensus of senior RAD and CAD together. Of the true nodules, the RAD detected 206 (93.2%) and 202 (91.4%) by the CAD. CAD and RAD together picked up more number of nodules than either CAD or RAD alone. Overall sensitivity for nodule detection with the CAD program was 91.4%, and FP detection per patient was 5.5%. The CAD showed comparatively higher sensitivity for nodules of size 4–10 mm (93.4%) and nodules in hilar (100%) and central (96.5%) location when compared to RAD's performance. CONCLUSION: CAD performance was high in detecting pulmonary nodules including the small size and low-density nodules. CAD even with relatively high FP rate, assists and improves RAD's performance as a second reader, especially for nodules located in the central and hilar region and for small nodules by saving RADs time. Medknow Publications & Media Pvt Ltd 2016 /pmc/articles/PMC4948226/ /pubmed/27578931 http://dx.doi.org/10.4103/0970-2113.184872 Text en Copyright: © Indian Chest Society http://creativecommons.org/licenses/by-nc-sa/3.0 This is an open access article distributed under the terms of the Creative Commons Attribution-NonCommercial-ShareAlike 3.0 License, which allows others to remix, tweak, and build upon the work non-commercially, as long as the author is credited and the new creations are licensed under the identical terms.
spellingShingle Original Article
Prakashini, K
Babu, Satish
Rajgopal, KV
Kokila, K Raja
Role of Computer Aided Diagnosis (CAD) in the detection of pulmonary nodules on 64 row multi detector computed tomography
title Role of Computer Aided Diagnosis (CAD) in the detection of pulmonary nodules on 64 row multi detector computed tomography
title_full Role of Computer Aided Diagnosis (CAD) in the detection of pulmonary nodules on 64 row multi detector computed tomography
title_fullStr Role of Computer Aided Diagnosis (CAD) in the detection of pulmonary nodules on 64 row multi detector computed tomography
title_full_unstemmed Role of Computer Aided Diagnosis (CAD) in the detection of pulmonary nodules on 64 row multi detector computed tomography
title_short Role of Computer Aided Diagnosis (CAD) in the detection of pulmonary nodules on 64 row multi detector computed tomography
title_sort role of computer aided diagnosis (cad) in the detection of pulmonary nodules on 64 row multi detector computed tomography
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4948226/
https://www.ncbi.nlm.nih.gov/pubmed/27578931
http://dx.doi.org/10.4103/0970-2113.184872
work_keys_str_mv AT prakashinik roleofcomputeraideddiagnosiscadinthedetectionofpulmonarynoduleson64rowmultidetectorcomputedtomography
AT babusatish roleofcomputeraideddiagnosiscadinthedetectionofpulmonarynoduleson64rowmultidetectorcomputedtomography
AT rajgopalkv roleofcomputeraideddiagnosiscadinthedetectionofpulmonarynoduleson64rowmultidetectorcomputedtomography
AT kokilakraja roleofcomputeraideddiagnosiscadinthedetectionofpulmonarynoduleson64rowmultidetectorcomputedtomography