Cargando…

Velocity measurements in whole blood using acoustic resolution photoacoustic Doppler

Acoustic resolution photoacoustic Doppler velocimetry promises to overcome the spatial resolution and depth penetration limitations of current blood flow measuring methods. Despite successful implementation using blood-mimicking fluids, measurements in blood have proved challenging, thus preventing...

Descripción completa

Detalles Bibliográficos
Autores principales: Brunker, Joanna, Beard, Paul
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Optical Society of America 2016
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4948631/
https://www.ncbi.nlm.nih.gov/pubmed/27446707
http://dx.doi.org/10.1364/BOE.7.002789
_version_ 1782443308085149696
author Brunker, Joanna
Beard, Paul
author_facet Brunker, Joanna
Beard, Paul
author_sort Brunker, Joanna
collection PubMed
description Acoustic resolution photoacoustic Doppler velocimetry promises to overcome the spatial resolution and depth penetration limitations of current blood flow measuring methods. Despite successful implementation using blood-mimicking fluids, measurements in blood have proved challenging, thus preventing in vivo application. A common explanation for this difficulty is that whole blood is insufficiently heterogeneous relative to detector frequencies of tens of MHz compatible with deep tissue photoacoustic measurements. Through rigorous experimental measurements we provide new insight that refutes this assertion. We show for the first time that, by careful choice of the detector frequency and field-of-view, and by employing novel signal processing methods, it is possible to make velocity measurements in whole blood using transducers with frequencies in the tens of MHz range. These findings have important implications for the prospects of making deep tissue measurements of blood flow relevant to the study of microcirculatory abnormalities associated with cancer, diabetes, atherosclerosis and other conditions.
format Online
Article
Text
id pubmed-4948631
institution National Center for Biotechnology Information
language English
publishDate 2016
publisher Optical Society of America
record_format MEDLINE/PubMed
spelling pubmed-49486312016-07-21 Velocity measurements in whole blood using acoustic resolution photoacoustic Doppler Brunker, Joanna Beard, Paul Biomed Opt Express Article Acoustic resolution photoacoustic Doppler velocimetry promises to overcome the spatial resolution and depth penetration limitations of current blood flow measuring methods. Despite successful implementation using blood-mimicking fluids, measurements in blood have proved challenging, thus preventing in vivo application. A common explanation for this difficulty is that whole blood is insufficiently heterogeneous relative to detector frequencies of tens of MHz compatible with deep tissue photoacoustic measurements. Through rigorous experimental measurements we provide new insight that refutes this assertion. We show for the first time that, by careful choice of the detector frequency and field-of-view, and by employing novel signal processing methods, it is possible to make velocity measurements in whole blood using transducers with frequencies in the tens of MHz range. These findings have important implications for the prospects of making deep tissue measurements of blood flow relevant to the study of microcirculatory abnormalities associated with cancer, diabetes, atherosclerosis and other conditions. Optical Society of America 2016-06-23 /pmc/articles/PMC4948631/ /pubmed/27446707 http://dx.doi.org/10.1364/BOE.7.002789 Text en Published by The Optical Society under the terms of the Creative Commons Attribution 4.0 License. Further distribution of this work must maintain attribution to the author(s) and the published article’s title, journal citation, and DOI.
spellingShingle Article
Brunker, Joanna
Beard, Paul
Velocity measurements in whole blood using acoustic resolution photoacoustic Doppler
title Velocity measurements in whole blood using acoustic resolution photoacoustic Doppler
title_full Velocity measurements in whole blood using acoustic resolution photoacoustic Doppler
title_fullStr Velocity measurements in whole blood using acoustic resolution photoacoustic Doppler
title_full_unstemmed Velocity measurements in whole blood using acoustic resolution photoacoustic Doppler
title_short Velocity measurements in whole blood using acoustic resolution photoacoustic Doppler
title_sort velocity measurements in whole blood using acoustic resolution photoacoustic doppler
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4948631/
https://www.ncbi.nlm.nih.gov/pubmed/27446707
http://dx.doi.org/10.1364/BOE.7.002789
work_keys_str_mv AT brunkerjoanna velocitymeasurementsinwholebloodusingacousticresolutionphotoacousticdoppler
AT beardpaul velocitymeasurementsinwholebloodusingacousticresolutionphotoacousticdoppler