Cargando…

Wide-field optical coherence tomography angiography using extended field imaging technique to evaluate the nonperfusion area in retinal vein occlusion

PURPOSE: Optical coherence tomography angiography (OCTA) is a newly developed technology which allows us to reconstruct the three-dimensional chorioretinal vasculature without dye injection. OCTA is a noninvasive, rapid, and reproducible method to assess retinal ischemia. However, one of its limitat...

Descripción completa

Detalles Bibliográficos
Autores principales: Kimura, Masayo, Nozaki, Miho, Yoshida, Munenori, Ogura, Yuichiro
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Dove Medical Press 2016
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4948735/
https://www.ncbi.nlm.nih.gov/pubmed/27471374
http://dx.doi.org/10.2147/OPTH.S108630
_version_ 1782443322888945664
author Kimura, Masayo
Nozaki, Miho
Yoshida, Munenori
Ogura, Yuichiro
author_facet Kimura, Masayo
Nozaki, Miho
Yoshida, Munenori
Ogura, Yuichiro
author_sort Kimura, Masayo
collection PubMed
description PURPOSE: Optical coherence tomography angiography (OCTA) is a newly developed technology which allows us to reconstruct the three-dimensional chorioretinal vasculature without dye injection. OCTA is a noninvasive, rapid, and reproducible method to assess retinal ischemia. However, one of its limitations is the size of scanning area. A novel yet simple technique to expand the scan length on optical coherence tomography has been reported as an extended field imaging (EFI) technique. It involves imaging the posterior pole through trial frames fitted with a +20 diopter lens. We applied this technique to OCTA to evaluate retinal vein occlusion. MATERIALS AND METHODS: Ten eyes of nine patients with retinal vein occlusion were studied. The average age was 69.0 years (range: 49–93 years). We obtained OCTA images by using RTVue XR Avanti OCT with AngioVue(®). The images of OCTA with scan size of 8×8 mm were obtained with and without EFI, and then they were compared. RESULTS: OCTA with EFI technique was performed successfully in all eyes. The nonperfusion area was well defined in superficial capillary plexus layer. The images with EFI were able to capture the larger area of the fundus by an average of 188.5% than those without EFI. The posterior pole inside the vascular arcade was well covered with this technique. The area of the fundus imaged by OCTA with EFI technique was even larger than that of fluorescein angiography using Heidelberg Retina Angiograph 2, which captured a 30° field. CONCLUSION: Our results suggested that OCTA with EFI technique is very useful to evaluate the retinal ischemia in retinal vein occlusion.
format Online
Article
Text
id pubmed-4948735
institution National Center for Biotechnology Information
language English
publishDate 2016
publisher Dove Medical Press
record_format MEDLINE/PubMed
spelling pubmed-49487352016-07-28 Wide-field optical coherence tomography angiography using extended field imaging technique to evaluate the nonperfusion area in retinal vein occlusion Kimura, Masayo Nozaki, Miho Yoshida, Munenori Ogura, Yuichiro Clin Ophthalmol Original Research PURPOSE: Optical coherence tomography angiography (OCTA) is a newly developed technology which allows us to reconstruct the three-dimensional chorioretinal vasculature without dye injection. OCTA is a noninvasive, rapid, and reproducible method to assess retinal ischemia. However, one of its limitations is the size of scanning area. A novel yet simple technique to expand the scan length on optical coherence tomography has been reported as an extended field imaging (EFI) technique. It involves imaging the posterior pole through trial frames fitted with a +20 diopter lens. We applied this technique to OCTA to evaluate retinal vein occlusion. MATERIALS AND METHODS: Ten eyes of nine patients with retinal vein occlusion were studied. The average age was 69.0 years (range: 49–93 years). We obtained OCTA images by using RTVue XR Avanti OCT with AngioVue(®). The images of OCTA with scan size of 8×8 mm were obtained with and without EFI, and then they were compared. RESULTS: OCTA with EFI technique was performed successfully in all eyes. The nonperfusion area was well defined in superficial capillary plexus layer. The images with EFI were able to capture the larger area of the fundus by an average of 188.5% than those without EFI. The posterior pole inside the vascular arcade was well covered with this technique. The area of the fundus imaged by OCTA with EFI technique was even larger than that of fluorescein angiography using Heidelberg Retina Angiograph 2, which captured a 30° field. CONCLUSION: Our results suggested that OCTA with EFI technique is very useful to evaluate the retinal ischemia in retinal vein occlusion. Dove Medical Press 2016-07-13 /pmc/articles/PMC4948735/ /pubmed/27471374 http://dx.doi.org/10.2147/OPTH.S108630 Text en © 2016 Kimura et al. This work is published and licensed by Dove Medical Press Limited The full terms of this license are available at https://www.dovepress.com/terms.php and incorporate the Creative Commons Attribution – Non Commercial (unported, v3.0) License (http://creativecommons.org/licenses/by-nc/3.0/). By accessing the work you hereby accept the Terms. Non-commercial uses of the work are permitted without any further permission from Dove Medical Press Limited, provided the work is properly attributed.
spellingShingle Original Research
Kimura, Masayo
Nozaki, Miho
Yoshida, Munenori
Ogura, Yuichiro
Wide-field optical coherence tomography angiography using extended field imaging technique to evaluate the nonperfusion area in retinal vein occlusion
title Wide-field optical coherence tomography angiography using extended field imaging technique to evaluate the nonperfusion area in retinal vein occlusion
title_full Wide-field optical coherence tomography angiography using extended field imaging technique to evaluate the nonperfusion area in retinal vein occlusion
title_fullStr Wide-field optical coherence tomography angiography using extended field imaging technique to evaluate the nonperfusion area in retinal vein occlusion
title_full_unstemmed Wide-field optical coherence tomography angiography using extended field imaging technique to evaluate the nonperfusion area in retinal vein occlusion
title_short Wide-field optical coherence tomography angiography using extended field imaging technique to evaluate the nonperfusion area in retinal vein occlusion
title_sort wide-field optical coherence tomography angiography using extended field imaging technique to evaluate the nonperfusion area in retinal vein occlusion
topic Original Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4948735/
https://www.ncbi.nlm.nih.gov/pubmed/27471374
http://dx.doi.org/10.2147/OPTH.S108630
work_keys_str_mv AT kimuramasayo widefieldopticalcoherencetomographyangiographyusingextendedfieldimagingtechniquetoevaluatethenonperfusionareainretinalveinocclusion
AT nozakimiho widefieldopticalcoherencetomographyangiographyusingextendedfieldimagingtechniquetoevaluatethenonperfusionareainretinalveinocclusion
AT yoshidamunenori widefieldopticalcoherencetomographyangiographyusingextendedfieldimagingtechniquetoevaluatethenonperfusionareainretinalveinocclusion
AT ogurayuichiro widefieldopticalcoherencetomographyangiographyusingextendedfieldimagingtechniquetoevaluatethenonperfusionareainretinalveinocclusion