Cargando…
Wide-field optical coherence tomography angiography using extended field imaging technique to evaluate the nonperfusion area in retinal vein occlusion
PURPOSE: Optical coherence tomography angiography (OCTA) is a newly developed technology which allows us to reconstruct the three-dimensional chorioretinal vasculature without dye injection. OCTA is a noninvasive, rapid, and reproducible method to assess retinal ischemia. However, one of its limitat...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Dove Medical Press
2016
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4948735/ https://www.ncbi.nlm.nih.gov/pubmed/27471374 http://dx.doi.org/10.2147/OPTH.S108630 |
_version_ | 1782443322888945664 |
---|---|
author | Kimura, Masayo Nozaki, Miho Yoshida, Munenori Ogura, Yuichiro |
author_facet | Kimura, Masayo Nozaki, Miho Yoshida, Munenori Ogura, Yuichiro |
author_sort | Kimura, Masayo |
collection | PubMed |
description | PURPOSE: Optical coherence tomography angiography (OCTA) is a newly developed technology which allows us to reconstruct the three-dimensional chorioretinal vasculature without dye injection. OCTA is a noninvasive, rapid, and reproducible method to assess retinal ischemia. However, one of its limitations is the size of scanning area. A novel yet simple technique to expand the scan length on optical coherence tomography has been reported as an extended field imaging (EFI) technique. It involves imaging the posterior pole through trial frames fitted with a +20 diopter lens. We applied this technique to OCTA to evaluate retinal vein occlusion. MATERIALS AND METHODS: Ten eyes of nine patients with retinal vein occlusion were studied. The average age was 69.0 years (range: 49–93 years). We obtained OCTA images by using RTVue XR Avanti OCT with AngioVue(®). The images of OCTA with scan size of 8×8 mm were obtained with and without EFI, and then they were compared. RESULTS: OCTA with EFI technique was performed successfully in all eyes. The nonperfusion area was well defined in superficial capillary plexus layer. The images with EFI were able to capture the larger area of the fundus by an average of 188.5% than those without EFI. The posterior pole inside the vascular arcade was well covered with this technique. The area of the fundus imaged by OCTA with EFI technique was even larger than that of fluorescein angiography using Heidelberg Retina Angiograph 2, which captured a 30° field. CONCLUSION: Our results suggested that OCTA with EFI technique is very useful to evaluate the retinal ischemia in retinal vein occlusion. |
format | Online Article Text |
id | pubmed-4948735 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2016 |
publisher | Dove Medical Press |
record_format | MEDLINE/PubMed |
spelling | pubmed-49487352016-07-28 Wide-field optical coherence tomography angiography using extended field imaging technique to evaluate the nonperfusion area in retinal vein occlusion Kimura, Masayo Nozaki, Miho Yoshida, Munenori Ogura, Yuichiro Clin Ophthalmol Original Research PURPOSE: Optical coherence tomography angiography (OCTA) is a newly developed technology which allows us to reconstruct the three-dimensional chorioretinal vasculature without dye injection. OCTA is a noninvasive, rapid, and reproducible method to assess retinal ischemia. However, one of its limitations is the size of scanning area. A novel yet simple technique to expand the scan length on optical coherence tomography has been reported as an extended field imaging (EFI) technique. It involves imaging the posterior pole through trial frames fitted with a +20 diopter lens. We applied this technique to OCTA to evaluate retinal vein occlusion. MATERIALS AND METHODS: Ten eyes of nine patients with retinal vein occlusion were studied. The average age was 69.0 years (range: 49–93 years). We obtained OCTA images by using RTVue XR Avanti OCT with AngioVue(®). The images of OCTA with scan size of 8×8 mm were obtained with and without EFI, and then they were compared. RESULTS: OCTA with EFI technique was performed successfully in all eyes. The nonperfusion area was well defined in superficial capillary plexus layer. The images with EFI were able to capture the larger area of the fundus by an average of 188.5% than those without EFI. The posterior pole inside the vascular arcade was well covered with this technique. The area of the fundus imaged by OCTA with EFI technique was even larger than that of fluorescein angiography using Heidelberg Retina Angiograph 2, which captured a 30° field. CONCLUSION: Our results suggested that OCTA with EFI technique is very useful to evaluate the retinal ischemia in retinal vein occlusion. Dove Medical Press 2016-07-13 /pmc/articles/PMC4948735/ /pubmed/27471374 http://dx.doi.org/10.2147/OPTH.S108630 Text en © 2016 Kimura et al. This work is published and licensed by Dove Medical Press Limited The full terms of this license are available at https://www.dovepress.com/terms.php and incorporate the Creative Commons Attribution – Non Commercial (unported, v3.0) License (http://creativecommons.org/licenses/by-nc/3.0/). By accessing the work you hereby accept the Terms. Non-commercial uses of the work are permitted without any further permission from Dove Medical Press Limited, provided the work is properly attributed. |
spellingShingle | Original Research Kimura, Masayo Nozaki, Miho Yoshida, Munenori Ogura, Yuichiro Wide-field optical coherence tomography angiography using extended field imaging technique to evaluate the nonperfusion area in retinal vein occlusion |
title | Wide-field optical coherence tomography angiography using extended field imaging technique to evaluate the nonperfusion area in retinal vein occlusion |
title_full | Wide-field optical coherence tomography angiography using extended field imaging technique to evaluate the nonperfusion area in retinal vein occlusion |
title_fullStr | Wide-field optical coherence tomography angiography using extended field imaging technique to evaluate the nonperfusion area in retinal vein occlusion |
title_full_unstemmed | Wide-field optical coherence tomography angiography using extended field imaging technique to evaluate the nonperfusion area in retinal vein occlusion |
title_short | Wide-field optical coherence tomography angiography using extended field imaging technique to evaluate the nonperfusion area in retinal vein occlusion |
title_sort | wide-field optical coherence tomography angiography using extended field imaging technique to evaluate the nonperfusion area in retinal vein occlusion |
topic | Original Research |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4948735/ https://www.ncbi.nlm.nih.gov/pubmed/27471374 http://dx.doi.org/10.2147/OPTH.S108630 |
work_keys_str_mv | AT kimuramasayo widefieldopticalcoherencetomographyangiographyusingextendedfieldimagingtechniquetoevaluatethenonperfusionareainretinalveinocclusion AT nozakimiho widefieldopticalcoherencetomographyangiographyusingextendedfieldimagingtechniquetoevaluatethenonperfusionareainretinalveinocclusion AT yoshidamunenori widefieldopticalcoherencetomographyangiographyusingextendedfieldimagingtechniquetoevaluatethenonperfusionareainretinalveinocclusion AT ogurayuichiro widefieldopticalcoherencetomographyangiographyusingextendedfieldimagingtechniquetoevaluatethenonperfusionareainretinalveinocclusion |