Cargando…
The Shoulder Function Index (SFInX): evaluation of its measurement properties in people recovering from a proximal humeral fracture
BACKGROUND: Concerns about test administration, reliability estimations, content and internal structure (dimensionality) of available shoulder measures for people with proximal humeral facture led to the development of a new clinician-observed outcome measure: the Shoulder Function Index (SFInX). Th...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
BioMed Central
2016
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4950219/ https://www.ncbi.nlm.nih.gov/pubmed/27431393 http://dx.doi.org/10.1186/s12891-016-1138-0 |
_version_ | 1782443543308009472 |
---|---|
author | van de Water, Alexander T. M. Davidson, Megan Shields, Nora Evans, Matthew C. Taylor, Nicholas F. |
author_facet | van de Water, Alexander T. M. Davidson, Megan Shields, Nora Evans, Matthew C. Taylor, Nicholas F. |
author_sort | van de Water, Alexander T. M. |
collection | PubMed |
description | BACKGROUND: Concerns about test administration, reliability estimations, content and internal structure (dimensionality) of available shoulder measures for people with proximal humeral facture led to the development of a new clinician-observed outcome measure: the Shoulder Function Index (SFInX). The SFInX measures shoulder function by judgement of actual ability to perform daily tasks in which the shoulder is involved. Patients and health professionals had input into the instrument development, and Rasch analysis was used to create a unidimensional, interval-level scale. This study comprehensively evaluated the measurement properties of the SFInX in people recovering from a proximal humeral fracture. METHODS: Data were collected on 92 people [79 women, mean age 63.5 years (SD13.9)] who sustained a proximal humeral fracture within the previous year on three occasions to allow for evaluation of the following measurement properties: construct validity (convergent, discriminant and known-groups validity), longitudinal validity (responsiveness), intra-rater reliability (one week retest interval), and inter-rater reliability (n = 20 subgroup; two independent raters). Comparative measures were Constant Score and Disabilities of the Arm Shoulder and Hand (DASH) and discriminative measure was a mental status questionnaire. Minimal clinically important difference, floor and ceiling effects and feasibility of the SFInX were also evaluated. A priori hypotheses were formulated where applicable. RESULTS: Results for construct validity testing supported hypothesised relationships (convergent validity r = 0.75–0.89 (Constant Score and DASH); discriminant validity r = −0.08 (mental status); known-groups validity r = 0.50). For longitudinal validity, lower correlations (r = 0.40–0.49) than hypothesised (r = 0.50–0.70) were found. The SFInX scores changed more (10.3 points) than other scales, which could indicate that the SFInX is more responsive than the comparative measures. Intra-rater and inter-rater reliability found ICCs of 0.96 (95 % CI 0.94–0.97) and 0.91 (95 % CI 0.63–0.97) respectively, with low measurement error (SEM = 3.9–5.8/100). A change of 11–12 points (out of 100) was indicative of a clinically important difference. CONCLUSIONS: The SFInX is a feasible outcome measure which clinicians can use to reliably measure and detect clinically important changes in the construct of ‘shoulder function’, the ability to perform activities in which the shoulder is involved, in people recovering from a proximal humeral fracture. |
format | Online Article Text |
id | pubmed-4950219 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2016 |
publisher | BioMed Central |
record_format | MEDLINE/PubMed |
spelling | pubmed-49502192016-07-20 The Shoulder Function Index (SFInX): evaluation of its measurement properties in people recovering from a proximal humeral fracture van de Water, Alexander T. M. Davidson, Megan Shields, Nora Evans, Matthew C. Taylor, Nicholas F. BMC Musculoskelet Disord Research Article BACKGROUND: Concerns about test administration, reliability estimations, content and internal structure (dimensionality) of available shoulder measures for people with proximal humeral facture led to the development of a new clinician-observed outcome measure: the Shoulder Function Index (SFInX). The SFInX measures shoulder function by judgement of actual ability to perform daily tasks in which the shoulder is involved. Patients and health professionals had input into the instrument development, and Rasch analysis was used to create a unidimensional, interval-level scale. This study comprehensively evaluated the measurement properties of the SFInX in people recovering from a proximal humeral fracture. METHODS: Data were collected on 92 people [79 women, mean age 63.5 years (SD13.9)] who sustained a proximal humeral fracture within the previous year on three occasions to allow for evaluation of the following measurement properties: construct validity (convergent, discriminant and known-groups validity), longitudinal validity (responsiveness), intra-rater reliability (one week retest interval), and inter-rater reliability (n = 20 subgroup; two independent raters). Comparative measures were Constant Score and Disabilities of the Arm Shoulder and Hand (DASH) and discriminative measure was a mental status questionnaire. Minimal clinically important difference, floor and ceiling effects and feasibility of the SFInX were also evaluated. A priori hypotheses were formulated where applicable. RESULTS: Results for construct validity testing supported hypothesised relationships (convergent validity r = 0.75–0.89 (Constant Score and DASH); discriminant validity r = −0.08 (mental status); known-groups validity r = 0.50). For longitudinal validity, lower correlations (r = 0.40–0.49) than hypothesised (r = 0.50–0.70) were found. The SFInX scores changed more (10.3 points) than other scales, which could indicate that the SFInX is more responsive than the comparative measures. Intra-rater and inter-rater reliability found ICCs of 0.96 (95 % CI 0.94–0.97) and 0.91 (95 % CI 0.63–0.97) respectively, with low measurement error (SEM = 3.9–5.8/100). A change of 11–12 points (out of 100) was indicative of a clinically important difference. CONCLUSIONS: The SFInX is a feasible outcome measure which clinicians can use to reliably measure and detect clinically important changes in the construct of ‘shoulder function’, the ability to perform activities in which the shoulder is involved, in people recovering from a proximal humeral fracture. BioMed Central 2016-07-18 /pmc/articles/PMC4950219/ /pubmed/27431393 http://dx.doi.org/10.1186/s12891-016-1138-0 Text en © The Author(s). 2016 Open AccessThis article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated. |
spellingShingle | Research Article van de Water, Alexander T. M. Davidson, Megan Shields, Nora Evans, Matthew C. Taylor, Nicholas F. The Shoulder Function Index (SFInX): evaluation of its measurement properties in people recovering from a proximal humeral fracture |
title | The Shoulder Function Index (SFInX): evaluation of its measurement properties in people recovering from a proximal humeral fracture |
title_full | The Shoulder Function Index (SFInX): evaluation of its measurement properties in people recovering from a proximal humeral fracture |
title_fullStr | The Shoulder Function Index (SFInX): evaluation of its measurement properties in people recovering from a proximal humeral fracture |
title_full_unstemmed | The Shoulder Function Index (SFInX): evaluation of its measurement properties in people recovering from a proximal humeral fracture |
title_short | The Shoulder Function Index (SFInX): evaluation of its measurement properties in people recovering from a proximal humeral fracture |
title_sort | shoulder function index (sfinx): evaluation of its measurement properties in people recovering from a proximal humeral fracture |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4950219/ https://www.ncbi.nlm.nih.gov/pubmed/27431393 http://dx.doi.org/10.1186/s12891-016-1138-0 |
work_keys_str_mv | AT vandewateralexandertm theshoulderfunctionindexsfinxevaluationofitsmeasurementpropertiesinpeoplerecoveringfromaproximalhumeralfracture AT davidsonmegan theshoulderfunctionindexsfinxevaluationofitsmeasurementpropertiesinpeoplerecoveringfromaproximalhumeralfracture AT shieldsnora theshoulderfunctionindexsfinxevaluationofitsmeasurementpropertiesinpeoplerecoveringfromaproximalhumeralfracture AT evansmatthewc theshoulderfunctionindexsfinxevaluationofitsmeasurementpropertiesinpeoplerecoveringfromaproximalhumeralfracture AT taylornicholasf theshoulderfunctionindexsfinxevaluationofitsmeasurementpropertiesinpeoplerecoveringfromaproximalhumeralfracture AT vandewateralexandertm shoulderfunctionindexsfinxevaluationofitsmeasurementpropertiesinpeoplerecoveringfromaproximalhumeralfracture AT davidsonmegan shoulderfunctionindexsfinxevaluationofitsmeasurementpropertiesinpeoplerecoveringfromaproximalhumeralfracture AT shieldsnora shoulderfunctionindexsfinxevaluationofitsmeasurementpropertiesinpeoplerecoveringfromaproximalhumeralfracture AT evansmatthewc shoulderfunctionindexsfinxevaluationofitsmeasurementpropertiesinpeoplerecoveringfromaproximalhumeralfracture AT taylornicholasf shoulderfunctionindexsfinxevaluationofitsmeasurementpropertiesinpeoplerecoveringfromaproximalhumeralfracture |