Cargando…

Diagnosis and stage of Graves' ophthalmopathy: Efficacy of quantitative measurements of the lacrimal gland based on 3-T magnetic resonance imaging

The aim of the present study was to determine the efficacy of quantitative measurements of the lacrimal gland based on 3-T magnetic resonance (MR) imaging in the diagnosis and staging of Graves' ophthalmopathy (GO). The study retrospectively enrolled 33 patients with GO (the GO group) and 24 he...

Descripción completa

Detalles Bibliográficos
Autores principales: Hu, Hao, Xu, Xiao-Quan, Wu, Fei-Yun, Chen, Huan-Huan, Su, Guo-Yi, Shen, Jie, Hong, Xun-Ning, Shi, Hai-Bin
Formato: Online Artículo Texto
Lenguaje:English
Publicado: D.A. Spandidos 2016
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4950689/
https://www.ncbi.nlm.nih.gov/pubmed/27446267
http://dx.doi.org/10.3892/etm.2016.3389
_version_ 1782443592322646016
author Hu, Hao
Xu, Xiao-Quan
Wu, Fei-Yun
Chen, Huan-Huan
Su, Guo-Yi
Shen, Jie
Hong, Xun-Ning
Shi, Hai-Bin
author_facet Hu, Hao
Xu, Xiao-Quan
Wu, Fei-Yun
Chen, Huan-Huan
Su, Guo-Yi
Shen, Jie
Hong, Xun-Ning
Shi, Hai-Bin
author_sort Hu, Hao
collection PubMed
description The aim of the present study was to determine the efficacy of quantitative measurements of the lacrimal gland based on 3-T magnetic resonance (MR) imaging in the diagnosis and staging of Graves' ophthalmopathy (GO). The study retrospectively enrolled 33 patients with GO (the GO group) and 24 healthy volunteers [the healthy control (HC) group] with orbit MR imaging performed using a 3-T MR scanner. Quantitative parameters of the lacrimal gland, including axial length, axial width, axial area, coronal length, coronal width, coronal area, volume and signal intensity ratio (SIR) of the lacrimal gland to the ipsilateral temporal muscle were measured. The difference of quantitative parameters between the GO and HC groups, or between active and inactive GO groups were evaluated using a Student's t-test. Receiver operating characteristic analyses were used to evaluate the diagnostic value of the significant parameters in discriminating patients with GO from healthy controls, or discriminating active from inactive GO. All the quantitative measurements of the GO patients were significantly larger than those of the healthy controls (P<0.05), with the exception of the coronal length (P=0.150). Axial and coronal width had the best efficacy in discriminating patients with GO from healthy controls. Only SIR was found to be different between the active and inactive GO groups (P=0.001). Setting a SIR of 2.57 as the threshold value, the optimal efficacy was achieved (area under the curve, 0.711; sensitivity, 57.7%; specificity, 77.5%) in discriminating between active and inactive GO. Quantitative measurements of the lacrimal gland based on 3-T MR imaging may assist in the diagnosis and stage of GO.
format Online
Article
Text
id pubmed-4950689
institution National Center for Biotechnology Information
language English
publishDate 2016
publisher D.A. Spandidos
record_format MEDLINE/PubMed
spelling pubmed-49506892016-07-21 Diagnosis and stage of Graves' ophthalmopathy: Efficacy of quantitative measurements of the lacrimal gland based on 3-T magnetic resonance imaging Hu, Hao Xu, Xiao-Quan Wu, Fei-Yun Chen, Huan-Huan Su, Guo-Yi Shen, Jie Hong, Xun-Ning Shi, Hai-Bin Exp Ther Med Articles The aim of the present study was to determine the efficacy of quantitative measurements of the lacrimal gland based on 3-T magnetic resonance (MR) imaging in the diagnosis and staging of Graves' ophthalmopathy (GO). The study retrospectively enrolled 33 patients with GO (the GO group) and 24 healthy volunteers [the healthy control (HC) group] with orbit MR imaging performed using a 3-T MR scanner. Quantitative parameters of the lacrimal gland, including axial length, axial width, axial area, coronal length, coronal width, coronal area, volume and signal intensity ratio (SIR) of the lacrimal gland to the ipsilateral temporal muscle were measured. The difference of quantitative parameters between the GO and HC groups, or between active and inactive GO groups were evaluated using a Student's t-test. Receiver operating characteristic analyses were used to evaluate the diagnostic value of the significant parameters in discriminating patients with GO from healthy controls, or discriminating active from inactive GO. All the quantitative measurements of the GO patients were significantly larger than those of the healthy controls (P<0.05), with the exception of the coronal length (P=0.150). Axial and coronal width had the best efficacy in discriminating patients with GO from healthy controls. Only SIR was found to be different between the active and inactive GO groups (P=0.001). Setting a SIR of 2.57 as the threshold value, the optimal efficacy was achieved (area under the curve, 0.711; sensitivity, 57.7%; specificity, 77.5%) in discriminating between active and inactive GO. Quantitative measurements of the lacrimal gland based on 3-T MR imaging may assist in the diagnosis and stage of GO. D.A. Spandidos 2016-08 2016-05-25 /pmc/articles/PMC4950689/ /pubmed/27446267 http://dx.doi.org/10.3892/etm.2016.3389 Text en Copyright: © Hu et al. This is an open access article distributed under the terms of the Creative Commons Attribution-NonCommercial-NoDerivs License (https://creativecommons.org/licenses/by-nc-nd/4.0/) , which permits use and distribution in any medium, provided the original work is properly cited, the use is non-commercial and no modifications or adaptations are made.
spellingShingle Articles
Hu, Hao
Xu, Xiao-Quan
Wu, Fei-Yun
Chen, Huan-Huan
Su, Guo-Yi
Shen, Jie
Hong, Xun-Ning
Shi, Hai-Bin
Diagnosis and stage of Graves' ophthalmopathy: Efficacy of quantitative measurements of the lacrimal gland based on 3-T magnetic resonance imaging
title Diagnosis and stage of Graves' ophthalmopathy: Efficacy of quantitative measurements of the lacrimal gland based on 3-T magnetic resonance imaging
title_full Diagnosis and stage of Graves' ophthalmopathy: Efficacy of quantitative measurements of the lacrimal gland based on 3-T magnetic resonance imaging
title_fullStr Diagnosis and stage of Graves' ophthalmopathy: Efficacy of quantitative measurements of the lacrimal gland based on 3-T magnetic resonance imaging
title_full_unstemmed Diagnosis and stage of Graves' ophthalmopathy: Efficacy of quantitative measurements of the lacrimal gland based on 3-T magnetic resonance imaging
title_short Diagnosis and stage of Graves' ophthalmopathy: Efficacy of quantitative measurements of the lacrimal gland based on 3-T magnetic resonance imaging
title_sort diagnosis and stage of graves' ophthalmopathy: efficacy of quantitative measurements of the lacrimal gland based on 3-t magnetic resonance imaging
topic Articles
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4950689/
https://www.ncbi.nlm.nih.gov/pubmed/27446267
http://dx.doi.org/10.3892/etm.2016.3389
work_keys_str_mv AT huhao diagnosisandstageofgravesophthalmopathyefficacyofquantitativemeasurementsofthelacrimalglandbasedon3tmagneticresonanceimaging
AT xuxiaoquan diagnosisandstageofgravesophthalmopathyefficacyofquantitativemeasurementsofthelacrimalglandbasedon3tmagneticresonanceimaging
AT wufeiyun diagnosisandstageofgravesophthalmopathyefficacyofquantitativemeasurementsofthelacrimalglandbasedon3tmagneticresonanceimaging
AT chenhuanhuan diagnosisandstageofgravesophthalmopathyefficacyofquantitativemeasurementsofthelacrimalglandbasedon3tmagneticresonanceimaging
AT suguoyi diagnosisandstageofgravesophthalmopathyefficacyofquantitativemeasurementsofthelacrimalglandbasedon3tmagneticresonanceimaging
AT shenjie diagnosisandstageofgravesophthalmopathyefficacyofquantitativemeasurementsofthelacrimalglandbasedon3tmagneticresonanceimaging
AT hongxunning diagnosisandstageofgravesophthalmopathyefficacyofquantitativemeasurementsofthelacrimalglandbasedon3tmagneticresonanceimaging
AT shihaibin diagnosisandstageofgravesophthalmopathyefficacyofquantitativemeasurementsofthelacrimalglandbasedon3tmagneticresonanceimaging