Optimal Needle Placement for Extensor Hallucis Longus Muscle: A Cadaveric Study
OBJECTIVE: To determine the midpoint (MD) of extensor hallucis longus muscle (EHL) and compare the accuracy of different needle electromyography (EMG) insertion techniques through cadaver dissection. METHODS: Thirty-eight limbs of 19 cadavers were dissected. The MD of EHL was marked at the middle of...
Autores principales: | Cheong, In Yae, Kim, Do Kyun, Oh, Ye Jeong, Park, Byung Kyu, Kim, Ki Hoon, Kim, Dong Hwee |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Korean Academy of Rehabilitation Medicine
2016
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4951364/ https://www.ncbi.nlm.nih.gov/pubmed/27446782 http://dx.doi.org/10.5535/arm.2016.40.3.457 |