Robotic Single-Site® Sacrocolpopexy: First Report and Technique Using the Single-Site® Wristed Needle Driver

The recently introduced da Vinci Single-Site® platform offers cosmetic benefits when compared with standard Multi-Site® robotic surgery. The innovative endowristed technology has increased the use of the da Vinci Single-Site® platform. The newly introduced Single-Site® Wristed Needle Driver has made...

Descripción completa

Detalles Bibliográficos
Autor principal: Lee, Sa Ra
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Yonsei University College of Medicine 2016
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4951446/
https://www.ncbi.nlm.nih.gov/pubmed/27189301
http://dx.doi.org/10.3349/ymj.2016.57.4.1029
_version_ 1782443703692951552
author Lee, Sa Ra
author_facet Lee, Sa Ra
author_sort Lee, Sa Ra
collection PubMed
description The recently introduced da Vinci Single-Site® platform offers cosmetic benefits when compared with standard Multi-Site® robotic surgery. The innovative endowristed technology has increased the use of the da Vinci Single-Site® platform. The newly introduced Single-Site® Wristed Needle Driver has made it feasible to perform various surgeries that require multiple laparoscopic sutures and knot tying. Laparoscopic sacrocolpopexy is also a type of technically difficult surgery requiring multiple sutures, and there have been no reports of it being performed using the da Vinci Single-Site® platform. Thus, to the best of our knowledge, this is the first report of robotic single-site (RSS) sacrocolpopexy, and I found this procedure to be feasible and safe. All RSS procedures were completed successfully. The mean operative time was 122.17±22.54 minutes, and the mean blood loss was 66.67±45.02 mL. No operative or major postoperative complications occurred. Additional studies should be performed to assess the benefits of RSS sacrocolpopexy. I present the first six cases of da Vinci Single-Site® surgery in urogynecology and provide a detailed description of the technique.
format Online
Article
Text
id pubmed-4951446
institution National Center for Biotechnology Information
language English
publishDate 2016
publisher Yonsei University College of Medicine
record_format MEDLINE/PubMed
spelling pubmed-49514462016-07-20 Robotic Single-Site® Sacrocolpopexy: First Report and Technique Using the Single-Site® Wristed Needle Driver Lee, Sa Ra Yonsei Med J Technical Report The recently introduced da Vinci Single-Site® platform offers cosmetic benefits when compared with standard Multi-Site® robotic surgery. The innovative endowristed technology has increased the use of the da Vinci Single-Site® platform. The newly introduced Single-Site® Wristed Needle Driver has made it feasible to perform various surgeries that require multiple laparoscopic sutures and knot tying. Laparoscopic sacrocolpopexy is also a type of technically difficult surgery requiring multiple sutures, and there have been no reports of it being performed using the da Vinci Single-Site® platform. Thus, to the best of our knowledge, this is the first report of robotic single-site (RSS) sacrocolpopexy, and I found this procedure to be feasible and safe. All RSS procedures were completed successfully. The mean operative time was 122.17±22.54 minutes, and the mean blood loss was 66.67±45.02 mL. No operative or major postoperative complications occurred. Additional studies should be performed to assess the benefits of RSS sacrocolpopexy. I present the first six cases of da Vinci Single-Site® surgery in urogynecology and provide a detailed description of the technique. Yonsei University College of Medicine 2016-07-01 2016-05-10 /pmc/articles/PMC4951446/ /pubmed/27189301 http://dx.doi.org/10.3349/ymj.2016.57.4.1029 Text en © Copyright: Yonsei University College of Medicine 2016 http://creativecommons.org/licenses/by-nc/3.0/ This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/3.0/) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Technical Report
Lee, Sa Ra
Robotic Single-Site® Sacrocolpopexy: First Report and Technique Using the Single-Site® Wristed Needle Driver
title Robotic Single-Site® Sacrocolpopexy: First Report and Technique Using the Single-Site® Wristed Needle Driver
title_full Robotic Single-Site® Sacrocolpopexy: First Report and Technique Using the Single-Site® Wristed Needle Driver
title_fullStr Robotic Single-Site® Sacrocolpopexy: First Report and Technique Using the Single-Site® Wristed Needle Driver
title_full_unstemmed Robotic Single-Site® Sacrocolpopexy: First Report and Technique Using the Single-Site® Wristed Needle Driver
title_short Robotic Single-Site® Sacrocolpopexy: First Report and Technique Using the Single-Site® Wristed Needle Driver
title_sort robotic single-site® sacrocolpopexy: first report and technique using the single-site® wristed needle driver
topic Technical Report
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4951446/
https://www.ncbi.nlm.nih.gov/pubmed/27189301
http://dx.doi.org/10.3349/ymj.2016.57.4.1029
work_keys_str_mv AT leesara roboticsinglesitesacrocolpopexyfirstreportandtechniqueusingthesinglesitewristedneedledriver