Standard versus Rotation Technique for Insertion of Supraglottic Airway Devices: Systematic Review and Meta-Analysis

PURPOSE: Supraglottic airway devices have been widely utilized as an alternative to tracheal intubation in various clinical situations. The rotation technique has been proposed to improve the insertion success rate of supraglottic airways. However, the clinical efficacy of this technique remains unc...

Descripción completa

Detalles Bibliográficos
Autores principales: Park, Jin Ha, Lee, Jong Seok, Nam, Sang Beom, Ju, Jin Wu, Kim, Min-Soo
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Yonsei University College of Medicine 2016
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4951479/
https://www.ncbi.nlm.nih.gov/pubmed/27189296
http://dx.doi.org/10.3349/ymj.2016.57.4.987
_version_ 1782443711296176128
author Park, Jin Ha
Lee, Jong Seok
Nam, Sang Beom
Ju, Jin Wu
Kim, Min-Soo
author_facet Park, Jin Ha
Lee, Jong Seok
Nam, Sang Beom
Ju, Jin Wu
Kim, Min-Soo
author_sort Park, Jin Ha
collection PubMed
description PURPOSE: Supraglottic airway devices have been widely utilized as an alternative to tracheal intubation in various clinical situations. The rotation technique has been proposed to improve the insertion success rate of supraglottic airways. However, the clinical efficacy of this technique remains uncertain as previous results have been inconsistent, depending on the variable evaluated. MATERIALS AND METHODS: We systematically searched PubMed, Embase, and the Cochrane Central Register of Controlled Trials in April 2015 for randomized controlled trials that compared the rotation and standard techniques for inserting supraglottic airways. RESULTS: Thirteen randomized controlled trials (1505 patients, 753 with the rotation technique) were included. The success rate at the first attempt was significantly higher with the rotation technique than with the standard technique [relative risk (RR): 1.13; 95% confidence interval (CI): 1.05 to 1.23; p=0.002]. The rotation technique provided significantly higher overall success rates (RR: 1.06; 95% CI: 1.04 to 1.09; p<0.001). Device insertion was completed faster with the rotation technique (mean difference: -4.6 seconds; 95% CI: -7.37 to -1.74; p=0.002). The incidence of blood staining on the removed device (RR: 0.36; 95% CI: 0.27 to 0.47; p<0.001) was significantly lower with the rotation technique. CONCLUSION: The rotation technique provided higher first-attempt and overall success rates, faster insertion, and a lower incidence of blood on the removed device, reflecting less mucosal trauma. Thus, it may be considered as an alternative to the standard technique when predicting or encountering difficulty in inserting supraglottic airways.
format Online
Article
Text
id pubmed-4951479
institution National Center for Biotechnology Information
language English
publishDate 2016
publisher Yonsei University College of Medicine
record_format MEDLINE/PubMed
spelling pubmed-49514792016-07-20 Standard versus Rotation Technique for Insertion of Supraglottic Airway Devices: Systematic Review and Meta-Analysis Park, Jin Ha Lee, Jong Seok Nam, Sang Beom Ju, Jin Wu Kim, Min-Soo Yonsei Med J Original Article PURPOSE: Supraglottic airway devices have been widely utilized as an alternative to tracheal intubation in various clinical situations. The rotation technique has been proposed to improve the insertion success rate of supraglottic airways. However, the clinical efficacy of this technique remains uncertain as previous results have been inconsistent, depending on the variable evaluated. MATERIALS AND METHODS: We systematically searched PubMed, Embase, and the Cochrane Central Register of Controlled Trials in April 2015 for randomized controlled trials that compared the rotation and standard techniques for inserting supraglottic airways. RESULTS: Thirteen randomized controlled trials (1505 patients, 753 with the rotation technique) were included. The success rate at the first attempt was significantly higher with the rotation technique than with the standard technique [relative risk (RR): 1.13; 95% confidence interval (CI): 1.05 to 1.23; p=0.002]. The rotation technique provided significantly higher overall success rates (RR: 1.06; 95% CI: 1.04 to 1.09; p<0.001). Device insertion was completed faster with the rotation technique (mean difference: -4.6 seconds; 95% CI: -7.37 to -1.74; p=0.002). The incidence of blood staining on the removed device (RR: 0.36; 95% CI: 0.27 to 0.47; p<0.001) was significantly lower with the rotation technique. CONCLUSION: The rotation technique provided higher first-attempt and overall success rates, faster insertion, and a lower incidence of blood on the removed device, reflecting less mucosal trauma. Thus, it may be considered as an alternative to the standard technique when predicting or encountering difficulty in inserting supraglottic airways. Yonsei University College of Medicine 2016-07-01 2016-05-10 /pmc/articles/PMC4951479/ /pubmed/27189296 http://dx.doi.org/10.3349/ymj.2016.57.4.987 Text en © Copyright: Yonsei University College of Medicine 2016 http://creativecommons.org/licenses/by-nc/3.0/ This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/3.0/) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Original Article
Park, Jin Ha
Lee, Jong Seok
Nam, Sang Beom
Ju, Jin Wu
Kim, Min-Soo
Standard versus Rotation Technique for Insertion of Supraglottic Airway Devices: Systematic Review and Meta-Analysis
title Standard versus Rotation Technique for Insertion of Supraglottic Airway Devices: Systematic Review and Meta-Analysis
title_full Standard versus Rotation Technique for Insertion of Supraglottic Airway Devices: Systematic Review and Meta-Analysis
title_fullStr Standard versus Rotation Technique for Insertion of Supraglottic Airway Devices: Systematic Review and Meta-Analysis
title_full_unstemmed Standard versus Rotation Technique for Insertion of Supraglottic Airway Devices: Systematic Review and Meta-Analysis
title_short Standard versus Rotation Technique for Insertion of Supraglottic Airway Devices: Systematic Review and Meta-Analysis
title_sort standard versus rotation technique for insertion of supraglottic airway devices: systematic review and meta-analysis
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4951479/
https://www.ncbi.nlm.nih.gov/pubmed/27189296
http://dx.doi.org/10.3349/ymj.2016.57.4.987
work_keys_str_mv AT parkjinha standardversusrotationtechniqueforinsertionofsupraglotticairwaydevicessystematicreviewandmetaanalysis
AT leejongseok standardversusrotationtechniqueforinsertionofsupraglotticairwaydevicessystematicreviewandmetaanalysis
AT namsangbeom standardversusrotationtechniqueforinsertionofsupraglotticairwaydevicessystematicreviewandmetaanalysis
AT jujinwu standardversusrotationtechniqueforinsertionofsupraglotticairwaydevicessystematicreviewandmetaanalysis
AT kimminsoo standardversusrotationtechniqueforinsertionofsupraglotticairwaydevicessystematicreviewandmetaanalysis