Accuracy, reliability, feasibility and nurse acceptance of a subcutaneous continuous glucose management system in critically ill patients: a prospective clinical trial

BACKGROUND: Continuous glucose monitoring (CGM) has not yet been implemented in the intensive care unit (ICU) setting. The purpose of this study was to evaluate reliability, feasibility, nurse acceptance and accuracy of the Medtronic Sentrino(®) CGM system in critically ill patients. METHODS: Sensor...

Descripción completa

Detalles Bibliográficos
Autores principales: Wollersheim, Tobias, Engelhardt, Lilian Jo, Pachulla, Jeanne, Moergeli, Rudolf, Koch, Susanne, Spies, Claudia, Hiesmayr, Michael, Weber-Carstens, Steffen
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Springer Paris 2016
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4954792/
https://www.ncbi.nlm.nih.gov/pubmed/27439710
http://dx.doi.org/10.1186/s13613-016-0167-z
_version_ 1782443829888024576
author Wollersheim, Tobias
Engelhardt, Lilian Jo
Pachulla, Jeanne
Moergeli, Rudolf
Koch, Susanne
Spies, Claudia
Hiesmayr, Michael
Weber-Carstens, Steffen
author_facet Wollersheim, Tobias
Engelhardt, Lilian Jo
Pachulla, Jeanne
Moergeli, Rudolf
Koch, Susanne
Spies, Claudia
Hiesmayr, Michael
Weber-Carstens, Steffen
author_sort Wollersheim, Tobias
collection PubMed
description BACKGROUND: Continuous glucose monitoring (CGM) has not yet been implemented in the intensive care unit (ICU) setting. The purpose of this study was to evaluate reliability, feasibility, nurse acceptance and accuracy of the Medtronic Sentrino(®) CGM system in critically ill patients. METHODS: Sensors were inserted into the subcutaneous tissue of the patient’s thigh, quantifying interstitial glucose concentration for up to 72 h per sensor. Reliability and feasibility analysis included frequency of data display, data gaps and reasons for sensor removal. We surveyed nurse acceptance in a questionnaire. For the accuracy analysis, we compared sensor values to glucose values obtained via blood gas analysis. Potential benefits of CGM were investigated in intra-individual analyses of factors, such as glycemic variability or time in target range achieved with CGM compared to that achieved with intermittent glucose monitoring. RESULTS: The device generated 68,655 real-time values from 31 sensors in 20 critically ill patients. 532 comparative blood glucose values were collected. Data were displayed during 32.5 h [16.0/62.4] per sensor, which is 45.1 % of the expected time of 72 h and 84.8 % of 37.9 h actual monitoring time. 21 out of 31 sensors were removed prematurely. 79.1 % of the nursing staff rated the device as not beneficial; the response rate was one-third. Mean absolute relative difference was 15.3 % (CI 13.5–17.0 %). Clarke error grid: 76.9 % zone A, 21.6 % zone B, 0.2 % zone C, 0.9 % zone D, 0.4 % zone E. Bland–Altman plot: mean bias +0.53 mg/dl, limits of agreement +64.6 and −63.5 mg/dl. Accuracy deteriorated during elevated glycemic variability and in the hyperglycemic range. There was no reduction in dysglycemic events during CGM compared to 72 h before and after CGM. If CGM was measuring accurately, it identified more hyperglycemic events when compared to intermittent measurements. This study was not designed to evaluate potential benefits of CGM on glucose control. CONCLUSIONS: The subcutaneous CGM system did not perform with satisfactory accuracy, feasibility, or nursing acceptance when evaluated in 20 medical-surgical ICU patients. Low point accuracy and prolonged data gaps significantly limited the potential clinical usefulness of the CGM trend data. Accurate continuous data display, with a MARD < 14 %, showed potential benefits in a subgroup of our patients. Trial registration NCT02296372; Ethic vote Charité EA2/095/14 ELECTRONIC SUPPLEMENTARY MATERIAL: The online version of this article (doi:10.1186/s13613-016-0167-z) contains supplementary material, which is available to authorized users.
format Online
Article
Text
id pubmed-4954792
institution National Center for Biotechnology Information
language English
publishDate 2016
publisher Springer Paris
record_format MEDLINE/PubMed
spelling pubmed-49547922016-08-01 Accuracy, reliability, feasibility and nurse acceptance of a subcutaneous continuous glucose management system in critically ill patients: a prospective clinical trial Wollersheim, Tobias Engelhardt, Lilian Jo Pachulla, Jeanne Moergeli, Rudolf Koch, Susanne Spies, Claudia Hiesmayr, Michael Weber-Carstens, Steffen Ann Intensive Care Research BACKGROUND: Continuous glucose monitoring (CGM) has not yet been implemented in the intensive care unit (ICU) setting. The purpose of this study was to evaluate reliability, feasibility, nurse acceptance and accuracy of the Medtronic Sentrino(®) CGM system in critically ill patients. METHODS: Sensors were inserted into the subcutaneous tissue of the patient’s thigh, quantifying interstitial glucose concentration for up to 72 h per sensor. Reliability and feasibility analysis included frequency of data display, data gaps and reasons for sensor removal. We surveyed nurse acceptance in a questionnaire. For the accuracy analysis, we compared sensor values to glucose values obtained via blood gas analysis. Potential benefits of CGM were investigated in intra-individual analyses of factors, such as glycemic variability or time in target range achieved with CGM compared to that achieved with intermittent glucose monitoring. RESULTS: The device generated 68,655 real-time values from 31 sensors in 20 critically ill patients. 532 comparative blood glucose values were collected. Data were displayed during 32.5 h [16.0/62.4] per sensor, which is 45.1 % of the expected time of 72 h and 84.8 % of 37.9 h actual monitoring time. 21 out of 31 sensors were removed prematurely. 79.1 % of the nursing staff rated the device as not beneficial; the response rate was one-third. Mean absolute relative difference was 15.3 % (CI 13.5–17.0 %). Clarke error grid: 76.9 % zone A, 21.6 % zone B, 0.2 % zone C, 0.9 % zone D, 0.4 % zone E. Bland–Altman plot: mean bias +0.53 mg/dl, limits of agreement +64.6 and −63.5 mg/dl. Accuracy deteriorated during elevated glycemic variability and in the hyperglycemic range. There was no reduction in dysglycemic events during CGM compared to 72 h before and after CGM. If CGM was measuring accurately, it identified more hyperglycemic events when compared to intermittent measurements. This study was not designed to evaluate potential benefits of CGM on glucose control. CONCLUSIONS: The subcutaneous CGM system did not perform with satisfactory accuracy, feasibility, or nursing acceptance when evaluated in 20 medical-surgical ICU patients. Low point accuracy and prolonged data gaps significantly limited the potential clinical usefulness of the CGM trend data. Accurate continuous data display, with a MARD < 14 %, showed potential benefits in a subgroup of our patients. Trial registration NCT02296372; Ethic vote Charité EA2/095/14 ELECTRONIC SUPPLEMENTARY MATERIAL: The online version of this article (doi:10.1186/s13613-016-0167-z) contains supplementary material, which is available to authorized users. Springer Paris 2016-07-21 /pmc/articles/PMC4954792/ /pubmed/27439710 http://dx.doi.org/10.1186/s13613-016-0167-z Text en © The Author(s) 2016 Open AccessThis article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made.
spellingShingle Research
Wollersheim, Tobias
Engelhardt, Lilian Jo
Pachulla, Jeanne
Moergeli, Rudolf
Koch, Susanne
Spies, Claudia
Hiesmayr, Michael
Weber-Carstens, Steffen
Accuracy, reliability, feasibility and nurse acceptance of a subcutaneous continuous glucose management system in critically ill patients: a prospective clinical trial
title Accuracy, reliability, feasibility and nurse acceptance of a subcutaneous continuous glucose management system in critically ill patients: a prospective clinical trial
title_full Accuracy, reliability, feasibility and nurse acceptance of a subcutaneous continuous glucose management system in critically ill patients: a prospective clinical trial
title_fullStr Accuracy, reliability, feasibility and nurse acceptance of a subcutaneous continuous glucose management system in critically ill patients: a prospective clinical trial
title_full_unstemmed Accuracy, reliability, feasibility and nurse acceptance of a subcutaneous continuous glucose management system in critically ill patients: a prospective clinical trial
title_short Accuracy, reliability, feasibility and nurse acceptance of a subcutaneous continuous glucose management system in critically ill patients: a prospective clinical trial
title_sort accuracy, reliability, feasibility and nurse acceptance of a subcutaneous continuous glucose management system in critically ill patients: a prospective clinical trial
topic Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4954792/
https://www.ncbi.nlm.nih.gov/pubmed/27439710
http://dx.doi.org/10.1186/s13613-016-0167-z
work_keys_str_mv AT wollersheimtobias accuracyreliabilityfeasibilityandnurseacceptanceofasubcutaneouscontinuousglucosemanagementsystemincriticallyillpatientsaprospectiveclinicaltrial
AT engelhardtlilianjo accuracyreliabilityfeasibilityandnurseacceptanceofasubcutaneouscontinuousglucosemanagementsystemincriticallyillpatientsaprospectiveclinicaltrial
AT pachullajeanne accuracyreliabilityfeasibilityandnurseacceptanceofasubcutaneouscontinuousglucosemanagementsystemincriticallyillpatientsaprospectiveclinicaltrial
AT moergelirudolf accuracyreliabilityfeasibilityandnurseacceptanceofasubcutaneouscontinuousglucosemanagementsystemincriticallyillpatientsaprospectiveclinicaltrial
AT kochsusanne accuracyreliabilityfeasibilityandnurseacceptanceofasubcutaneouscontinuousglucosemanagementsystemincriticallyillpatientsaprospectiveclinicaltrial
AT spiesclaudia accuracyreliabilityfeasibilityandnurseacceptanceofasubcutaneouscontinuousglucosemanagementsystemincriticallyillpatientsaprospectiveclinicaltrial
AT hiesmayrmichael accuracyreliabilityfeasibilityandnurseacceptanceofasubcutaneouscontinuousglucosemanagementsystemincriticallyillpatientsaprospectiveclinicaltrial
AT webercarstenssteffen accuracyreliabilityfeasibilityandnurseacceptanceofasubcutaneouscontinuousglucosemanagementsystemincriticallyillpatientsaprospectiveclinicaltrial