Cargando…

Usefulness of ultrasound examination in the evaluation of a neonate's body fluid status

Appropriate hydration is a very important prognostic factor for the patient's health. Ultrasonographic assessment of hydration status is rarely used in pediatric medicine and it is not used at all in neonates due to the fact that no reference values have been established for this age group. The...

Descripción completa

Detalles Bibliográficos
Autores principales: Kieliszczyk, Joanna, Baranowski, Wojciech, Kosiak, Wojciech
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Medical Communications Sp. z o.o. 2016
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4954858/
https://www.ncbi.nlm.nih.gov/pubmed/27446597
http://dx.doi.org/10.15557/JoU.2016.0014
_version_ 1782443844778852352
author Kieliszczyk, Joanna
Baranowski, Wojciech
Kosiak, Wojciech
author_facet Kieliszczyk, Joanna
Baranowski, Wojciech
Kosiak, Wojciech
author_sort Kieliszczyk, Joanna
collection PubMed
description Appropriate hydration is a very important prognostic factor for the patient's health. Ultrasonographic assessment of hydration status is rarely used in pediatric medicine and it is not used at all in neonates due to the fact that no reference values have been established for this age group. The aim of the paper was to establish reference values for neonates. MATERIAL AND METHODS: The study included 50 neonates from two hospitals in the Lower Silesia region of Poland; 25 of them were healthy patients (full-term newborns with no perinatal complications) and 25 were sick patients (newborns with heart defects such as ostium secundum atrial septal defect, ventricular septal defect, permanent foramen ovale and patent ductus arteriosus as well as newborns with neonatal jaundice or pneumonia that occurred during the first days of life). The ultrasound scans were conducted during the first days of the children's life. For every child inferior vena cava diameter was measured in the substernal area, longitudinal plane, M-mode in two respiratory phases: inhalation and exhalation. In addition, abdominal aorta diameter was determined (substernal area, transverse plane). RESULTS: The study demonstrated a statistically significant difference in the calculated inferior vena cava collapsibility index between both groups. Two other indices included the ratio of the inferior vena cava diameter during the expiratory phase to the diameter of the aorta and the ratio of the inferior vena cava diameter during the inspiratory phase to the diameter of the aorta; a statistically significant difference between both groups was found only for the measurements in the inspiratory phase. CONCLUSIONS: Based on the study results normal ranges for hydration indices in neonates were established. The need for the measurement of the abovementioned parameters in the inspiratory phase was determined. In addition, the usefulness of the ultrasound examination for the evaluation of body fluid status in this pediatric age group, particularly in preterm newborns, was noted due to its painless and non-invasive nature as well as easy access to equipment at neonatology wards.
format Online
Article
Text
id pubmed-4954858
institution National Center for Biotechnology Information
language English
publishDate 2016
publisher Medical Communications Sp. z o.o.
record_format MEDLINE/PubMed
spelling pubmed-49548582016-07-21 Usefulness of ultrasound examination in the evaluation of a neonate's body fluid status Kieliszczyk, Joanna Baranowski, Wojciech Kosiak, Wojciech J Ultrason Original Paper Appropriate hydration is a very important prognostic factor for the patient's health. Ultrasonographic assessment of hydration status is rarely used in pediatric medicine and it is not used at all in neonates due to the fact that no reference values have been established for this age group. The aim of the paper was to establish reference values for neonates. MATERIAL AND METHODS: The study included 50 neonates from two hospitals in the Lower Silesia region of Poland; 25 of them were healthy patients (full-term newborns with no perinatal complications) and 25 were sick patients (newborns with heart defects such as ostium secundum atrial septal defect, ventricular septal defect, permanent foramen ovale and patent ductus arteriosus as well as newborns with neonatal jaundice or pneumonia that occurred during the first days of life). The ultrasound scans were conducted during the first days of the children's life. For every child inferior vena cava diameter was measured in the substernal area, longitudinal plane, M-mode in two respiratory phases: inhalation and exhalation. In addition, abdominal aorta diameter was determined (substernal area, transverse plane). RESULTS: The study demonstrated a statistically significant difference in the calculated inferior vena cava collapsibility index between both groups. Two other indices included the ratio of the inferior vena cava diameter during the expiratory phase to the diameter of the aorta and the ratio of the inferior vena cava diameter during the inspiratory phase to the diameter of the aorta; a statistically significant difference between both groups was found only for the measurements in the inspiratory phase. CONCLUSIONS: Based on the study results normal ranges for hydration indices in neonates were established. The need for the measurement of the abovementioned parameters in the inspiratory phase was determined. In addition, the usefulness of the ultrasound examination for the evaluation of body fluid status in this pediatric age group, particularly in preterm newborns, was noted due to its painless and non-invasive nature as well as easy access to equipment at neonatology wards. Medical Communications Sp. z o.o. 2016-06-29 2016-06 /pmc/articles/PMC4954858/ /pubmed/27446597 http://dx.doi.org/10.15557/JoU.2016.0014 Text en 2016 Polish Ultrasound Society. Published by Medical Communications Sp. z o.o. All rights reserved. http://creativecommons.org/licenses/by-nc-nd This is an open-access article distributed under the terms of the Creative Commons Attribution-NonCommercial-NoDerivatives License (CC BY-NC-ND). Reproduction is permitted for personal, educational, non-commercial use, provided that the original article is in whole, unmodified, and properly cited.
spellingShingle Original Paper
Kieliszczyk, Joanna
Baranowski, Wojciech
Kosiak, Wojciech
Usefulness of ultrasound examination in the evaluation of a neonate's body fluid status
title Usefulness of ultrasound examination in the evaluation of a neonate's body fluid status
title_full Usefulness of ultrasound examination in the evaluation of a neonate's body fluid status
title_fullStr Usefulness of ultrasound examination in the evaluation of a neonate's body fluid status
title_full_unstemmed Usefulness of ultrasound examination in the evaluation of a neonate's body fluid status
title_short Usefulness of ultrasound examination in the evaluation of a neonate's body fluid status
title_sort usefulness of ultrasound examination in the evaluation of a neonate's body fluid status
topic Original Paper
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4954858/
https://www.ncbi.nlm.nih.gov/pubmed/27446597
http://dx.doi.org/10.15557/JoU.2016.0014
work_keys_str_mv AT kieliszczykjoanna usefulnessofultrasoundexaminationintheevaluationofaneonatesbodyfluidstatus
AT baranowskiwojciech usefulnessofultrasoundexaminationintheevaluationofaneonatesbodyfluidstatus
AT kosiakwojciech usefulnessofultrasoundexaminationintheevaluationofaneonatesbodyfluidstatus