Repair of tracheo-oesophageal fistula secondary to button battery ingestion: A combined cervical and median sternotomy approach
A three-year-old child developed a large tracheo-oesophageal fistula secondary to a button battery being lodged in the upper oesophagus for 36 hours. The diagnosis was confirmed with a contrast swallow. Operative access was gained through a combined right cervical incision and complete median sterno...