Cargando…

The hemisoleus rotational flap provides a novel superior autograft reconstructive option for the treatment of chronic extensor mechanism disruption

Chronic disruption of the extensor mechanism is a devastating problem after total knee arthroplasty. Quadriceps tendon ruptures occur at an estimated 0.1% prevalence in the setting of total knee arthroplasty. Complete tears of the quadriceps tendon generally have poor results and high rates of rerup...

Descripción completa

Detalles Bibliográficos
Autores principales: Auregan, Jean-Charles, Lin, James D., Lombardi, Joseph M., Jang, Eugene, Macaulay, William, Rosenwasser, Melvin P.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Elsevier 2016
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4957171/
https://www.ncbi.nlm.nih.gov/pubmed/28326398
http://dx.doi.org/10.1016/j.artd.2016.01.001
_version_ 1782444136027127808
author Auregan, Jean-Charles
Lin, James D.
Lombardi, Joseph M.
Jang, Eugene
Macaulay, William
Rosenwasser, Melvin P.
author_facet Auregan, Jean-Charles
Lin, James D.
Lombardi, Joseph M.
Jang, Eugene
Macaulay, William
Rosenwasser, Melvin P.
author_sort Auregan, Jean-Charles
collection PubMed
description Chronic disruption of the extensor mechanism is a devastating problem after total knee arthroplasty. Quadriceps tendon ruptures occur at an estimated 0.1% prevalence in the setting of total knee arthroplasty. Complete tears of the quadriceps tendon generally have poor results and high rates of rerupture. We present a case of a quadriceps tendon rupture after total knee arthroplasty which reruptured after initial direct repair. The patient presented to us with a chronically retracted rerupture and was subsequently reconstructed successfully with a novel extended medial gastrocnemius-soleus-calcaneus local rotational pedicle flap.
format Online
Article
Text
id pubmed-4957171
institution National Center for Biotechnology Information
language English
publishDate 2016
publisher Elsevier
record_format MEDLINE/PubMed
spelling pubmed-49571712017-03-21 The hemisoleus rotational flap provides a novel superior autograft reconstructive option for the treatment of chronic extensor mechanism disruption Auregan, Jean-Charles Lin, James D. Lombardi, Joseph M. Jang, Eugene Macaulay, William Rosenwasser, Melvin P. Arthroplasty Today Case Report Chronic disruption of the extensor mechanism is a devastating problem after total knee arthroplasty. Quadriceps tendon ruptures occur at an estimated 0.1% prevalence in the setting of total knee arthroplasty. Complete tears of the quadriceps tendon generally have poor results and high rates of rerupture. We present a case of a quadriceps tendon rupture after total knee arthroplasty which reruptured after initial direct repair. The patient presented to us with a chronically retracted rerupture and was subsequently reconstructed successfully with a novel extended medial gastrocnemius-soleus-calcaneus local rotational pedicle flap. Elsevier 2016-02-26 /pmc/articles/PMC4957171/ /pubmed/28326398 http://dx.doi.org/10.1016/j.artd.2016.01.001 Text en © 2016 The Authors http://creativecommons.org/licenses/by-nc-nd/4.0/ This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).
spellingShingle Case Report
Auregan, Jean-Charles
Lin, James D.
Lombardi, Joseph M.
Jang, Eugene
Macaulay, William
Rosenwasser, Melvin P.
The hemisoleus rotational flap provides a novel superior autograft reconstructive option for the treatment of chronic extensor mechanism disruption
title The hemisoleus rotational flap provides a novel superior autograft reconstructive option for the treatment of chronic extensor mechanism disruption
title_full The hemisoleus rotational flap provides a novel superior autograft reconstructive option for the treatment of chronic extensor mechanism disruption
title_fullStr The hemisoleus rotational flap provides a novel superior autograft reconstructive option for the treatment of chronic extensor mechanism disruption
title_full_unstemmed The hemisoleus rotational flap provides a novel superior autograft reconstructive option for the treatment of chronic extensor mechanism disruption
title_short The hemisoleus rotational flap provides a novel superior autograft reconstructive option for the treatment of chronic extensor mechanism disruption
title_sort hemisoleus rotational flap provides a novel superior autograft reconstructive option for the treatment of chronic extensor mechanism disruption
topic Case Report
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4957171/
https://www.ncbi.nlm.nih.gov/pubmed/28326398
http://dx.doi.org/10.1016/j.artd.2016.01.001
work_keys_str_mv AT aureganjeancharles thehemisoleusrotationalflapprovidesanovelsuperiorautograftreconstructiveoptionforthetreatmentofchronicextensormechanismdisruption
AT linjamesd thehemisoleusrotationalflapprovidesanovelsuperiorautograftreconstructiveoptionforthetreatmentofchronicextensormechanismdisruption
AT lombardijosephm thehemisoleusrotationalflapprovidesanovelsuperiorautograftreconstructiveoptionforthetreatmentofchronicextensormechanismdisruption
AT jangeugene thehemisoleusrotationalflapprovidesanovelsuperiorautograftreconstructiveoptionforthetreatmentofchronicextensormechanismdisruption
AT macaulaywilliam thehemisoleusrotationalflapprovidesanovelsuperiorautograftreconstructiveoptionforthetreatmentofchronicextensormechanismdisruption
AT rosenwassermelvinp thehemisoleusrotationalflapprovidesanovelsuperiorautograftreconstructiveoptionforthetreatmentofchronicextensormechanismdisruption
AT aureganjeancharles hemisoleusrotationalflapprovidesanovelsuperiorautograftreconstructiveoptionforthetreatmentofchronicextensormechanismdisruption
AT linjamesd hemisoleusrotationalflapprovidesanovelsuperiorautograftreconstructiveoptionforthetreatmentofchronicextensormechanismdisruption
AT lombardijosephm hemisoleusrotationalflapprovidesanovelsuperiorautograftreconstructiveoptionforthetreatmentofchronicextensormechanismdisruption
AT jangeugene hemisoleusrotationalflapprovidesanovelsuperiorautograftreconstructiveoptionforthetreatmentofchronicextensormechanismdisruption
AT macaulaywilliam hemisoleusrotationalflapprovidesanovelsuperiorautograftreconstructiveoptionforthetreatmentofchronicextensormechanismdisruption
AT rosenwassermelvinp hemisoleusrotationalflapprovidesanovelsuperiorautograftreconstructiveoptionforthetreatmentofchronicextensormechanismdisruption