Cargando…

Effects of Within-Talker Variability on Speech Intelligibility in Mandarin-Speaking Adult and Pediatric Cochlear Implant Patients

Cochlear implant (CI) speech performance is typically evaluated using well-enunciated speech produced at a normal rate by a single talker. CI users often have greater difficulty with variations in speech production encountered in everyday listening. Within a single talker, speaking rate, amplitude,...

Descripción completa

Detalles Bibliográficos
Autores principales: Su, Qiaotong, Galvin, John J., Zhang, Guoping, Li, Yongxin, Fu, Qian-Jie
Formato: Online Artículo Texto
Lenguaje:English
Publicado: SAGE Publications 2016
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4959306/
https://www.ncbi.nlm.nih.gov/pubmed/27363714
http://dx.doi.org/10.1177/2331216516654022
_version_ 1782444380690317312
author Su, Qiaotong
Galvin, John J.
Zhang, Guoping
Li, Yongxin
Fu, Qian-Jie
author_facet Su, Qiaotong
Galvin, John J.
Zhang, Guoping
Li, Yongxin
Fu, Qian-Jie
author_sort Su, Qiaotong
collection PubMed
description Cochlear implant (CI) speech performance is typically evaluated using well-enunciated speech produced at a normal rate by a single talker. CI users often have greater difficulty with variations in speech production encountered in everyday listening. Within a single talker, speaking rate, amplitude, duration, and voice pitch information may be quite variable, depending on the production context. The coarse spectral resolution afforded by the CI limits perception of voice pitch, which is an important cue for speech prosody and for tonal languages such as Mandarin Chinese. In this study, sentence recognition from the Mandarin speech perception database was measured in adult and pediatric Mandarin-speaking CI listeners for a variety of speaking styles: voiced speech produced at slow, normal, and fast speaking rates; whispered speech; voiced emotional speech; and voiced shouted speech. Recognition of Mandarin Hearing in Noise Test sentences was also measured. Results showed that performance was significantly poorer with whispered speech relative to the other speaking styles and that performance was significantly better with slow speech than with fast or emotional speech. Results also showed that adult and pediatric performance was significantly poorer with Mandarin Hearing in Noise Test than with Mandarin speech perception sentences at the normal rate. The results suggest that adult and pediatric Mandarin-speaking CI patients are highly susceptible to whispered speech, due to the lack of lexically important voice pitch cues and perhaps other qualities associated with whispered speech. The results also suggest that test materials may contribute to differences in performance observed between adult and pediatric CI users.
format Online
Article
Text
id pubmed-4959306
institution National Center for Biotechnology Information
language English
publishDate 2016
publisher SAGE Publications
record_format MEDLINE/PubMed
spelling pubmed-49593062016-08-04 Effects of Within-Talker Variability on Speech Intelligibility in Mandarin-Speaking Adult and Pediatric Cochlear Implant Patients Su, Qiaotong Galvin, John J. Zhang, Guoping Li, Yongxin Fu, Qian-Jie Trends Hear Original Articles Cochlear implant (CI) speech performance is typically evaluated using well-enunciated speech produced at a normal rate by a single talker. CI users often have greater difficulty with variations in speech production encountered in everyday listening. Within a single talker, speaking rate, amplitude, duration, and voice pitch information may be quite variable, depending on the production context. The coarse spectral resolution afforded by the CI limits perception of voice pitch, which is an important cue for speech prosody and for tonal languages such as Mandarin Chinese. In this study, sentence recognition from the Mandarin speech perception database was measured in adult and pediatric Mandarin-speaking CI listeners for a variety of speaking styles: voiced speech produced at slow, normal, and fast speaking rates; whispered speech; voiced emotional speech; and voiced shouted speech. Recognition of Mandarin Hearing in Noise Test sentences was also measured. Results showed that performance was significantly poorer with whispered speech relative to the other speaking styles and that performance was significantly better with slow speech than with fast or emotional speech. Results also showed that adult and pediatric performance was significantly poorer with Mandarin Hearing in Noise Test than with Mandarin speech perception sentences at the normal rate. The results suggest that adult and pediatric Mandarin-speaking CI patients are highly susceptible to whispered speech, due to the lack of lexically important voice pitch cues and perhaps other qualities associated with whispered speech. The results also suggest that test materials may contribute to differences in performance observed between adult and pediatric CI users. SAGE Publications 2016-06-30 /pmc/articles/PMC4959306/ /pubmed/27363714 http://dx.doi.org/10.1177/2331216516654022 Text en © The Author(s) 2016 http://creativecommons.org/licenses/by-nc/3.0/ This article is distributed under the terms of the Creative Commons Attribution-NonCommercial 3.0 License (http://www.creativecommons.org/licenses/by-nc/3.0/) which permits non-commercial use, reproduction and distribution of the work without further permission provided the original work is attributed as specified on the SAGE and Open Access page (https://us.sagepub.com/en-us/nam/open-access-at-sage).
spellingShingle Original Articles
Su, Qiaotong
Galvin, John J.
Zhang, Guoping
Li, Yongxin
Fu, Qian-Jie
Effects of Within-Talker Variability on Speech Intelligibility in Mandarin-Speaking Adult and Pediatric Cochlear Implant Patients
title Effects of Within-Talker Variability on Speech Intelligibility in Mandarin-Speaking Adult and Pediatric Cochlear Implant Patients
title_full Effects of Within-Talker Variability on Speech Intelligibility in Mandarin-Speaking Adult and Pediatric Cochlear Implant Patients
title_fullStr Effects of Within-Talker Variability on Speech Intelligibility in Mandarin-Speaking Adult and Pediatric Cochlear Implant Patients
title_full_unstemmed Effects of Within-Talker Variability on Speech Intelligibility in Mandarin-Speaking Adult and Pediatric Cochlear Implant Patients
title_short Effects of Within-Talker Variability on Speech Intelligibility in Mandarin-Speaking Adult and Pediatric Cochlear Implant Patients
title_sort effects of within-talker variability on speech intelligibility in mandarin-speaking adult and pediatric cochlear implant patients
topic Original Articles
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4959306/
https://www.ncbi.nlm.nih.gov/pubmed/27363714
http://dx.doi.org/10.1177/2331216516654022
work_keys_str_mv AT suqiaotong effectsofwithintalkervariabilityonspeechintelligibilityinmandarinspeakingadultandpediatriccochlearimplantpatients
AT galvinjohnj effectsofwithintalkervariabilityonspeechintelligibilityinmandarinspeakingadultandpediatriccochlearimplantpatients
AT zhangguoping effectsofwithintalkervariabilityonspeechintelligibilityinmandarinspeakingadultandpediatriccochlearimplantpatients
AT liyongxin effectsofwithintalkervariabilityonspeechintelligibilityinmandarinspeakingadultandpediatriccochlearimplantpatients
AT fuqianjie effectsofwithintalkervariabilityonspeechintelligibilityinmandarinspeakingadultandpediatriccochlearimplantpatients