Cargando…

Scattered Light and Other Corrections in Absorption Coefficient Measurements in the Vacuum Ultraviolet: A Systems Approach

A systems approach in which computer automation is applied to a vacuum ultraviolet spectrometer and auxiliary components is described. The errors associated with the measurement of gaseous absorption coefficients in the vacuum ultraviolet are considered. The presence of scattered light introduces la...

Descripción completa

Detalles Bibliográficos
Autores principales: Klein, R., Braun, W., Fahr, A., Mele, A., Okabe, H.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: [Gaithersburg, MD] : U.S. Dept. of Commerce, National Institute of Standards and Technology 1990
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4959400/
https://www.ncbi.nlm.nih.gov/pubmed/28179780
http://dx.doi.org/10.6028/jres.095.030
_version_ 1782444399624454144
author Klein, R.
Braun, W.
Fahr, A.
Mele, A.
Okabe, H.
author_facet Klein, R.
Braun, W.
Fahr, A.
Mele, A.
Okabe, H.
author_sort Klein, R.
collection PubMed
description A systems approach in which computer automation is applied to a vacuum ultraviolet spectrometer and auxiliary components is described. The errors associated with the measurement of gaseous absorption coefficients in the vacuum ultraviolet are considered. The presence of scattered light introduces large errors particularly at those wavelengths where the source used is characterized by low intensity. In the case of a D(2) light source this occurs in the region 120 to 130 nm. Simple considerations explain the variation of the absorption coefficient determinations in the presence of scattered light and lead to an appropriate treatment of the data to eliminate the error. Experimental results are presented illustrating the efficiency and precision obtainable with the present approach.
format Online
Article
Text
id pubmed-4959400
institution National Center for Biotechnology Information
language English
publishDate 1990
publisher [Gaithersburg, MD] : U.S. Dept. of Commerce, National Institute of Standards and Technology
record_format MEDLINE/PubMed
spelling pubmed-49594002017-02-08 Scattered Light and Other Corrections in Absorption Coefficient Measurements in the Vacuum Ultraviolet: A Systems Approach Klein, R. Braun, W. Fahr, A. Mele, A. Okabe, H. J Res Natl Inst Stand Technol Article A systems approach in which computer automation is applied to a vacuum ultraviolet spectrometer and auxiliary components is described. The errors associated with the measurement of gaseous absorption coefficients in the vacuum ultraviolet are considered. The presence of scattered light introduces large errors particularly at those wavelengths where the source used is characterized by low intensity. In the case of a D(2) light source this occurs in the region 120 to 130 nm. Simple considerations explain the variation of the absorption coefficient determinations in the presence of scattered light and lead to an appropriate treatment of the data to eliminate the error. Experimental results are presented illustrating the efficiency and precision obtainable with the present approach. [Gaithersburg, MD] : U.S. Dept. of Commerce, National Institute of Standards and Technology 1990 /pmc/articles/PMC4959400/ /pubmed/28179780 http://dx.doi.org/10.6028/jres.095.030 Text en https://creativecommons.org/publicdomain/zero/1.0/ The Journal of Research of the National Institute of Standards and Technology is a publication of the U.S. Government. The papers are in the public domain and are not subject to copyright in the United States. Articles from J Res may contain photographs or illustrations copyrighted by other commercial organizations or individuals that may not be used without obtaining prior approval from the holder of the copyright.
spellingShingle Article
Klein, R.
Braun, W.
Fahr, A.
Mele, A.
Okabe, H.
Scattered Light and Other Corrections in Absorption Coefficient Measurements in the Vacuum Ultraviolet: A Systems Approach
title Scattered Light and Other Corrections in Absorption Coefficient Measurements in the Vacuum Ultraviolet: A Systems Approach
title_full Scattered Light and Other Corrections in Absorption Coefficient Measurements in the Vacuum Ultraviolet: A Systems Approach
title_fullStr Scattered Light and Other Corrections in Absorption Coefficient Measurements in the Vacuum Ultraviolet: A Systems Approach
title_full_unstemmed Scattered Light and Other Corrections in Absorption Coefficient Measurements in the Vacuum Ultraviolet: A Systems Approach
title_short Scattered Light and Other Corrections in Absorption Coefficient Measurements in the Vacuum Ultraviolet: A Systems Approach
title_sort scattered light and other corrections in absorption coefficient measurements in the vacuum ultraviolet: a systems approach
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4959400/
https://www.ncbi.nlm.nih.gov/pubmed/28179780
http://dx.doi.org/10.6028/jres.095.030
work_keys_str_mv AT kleinr scatteredlightandothercorrectionsinabsorptioncoefficientmeasurementsinthevacuumultravioletasystemsapproach
AT braunw scatteredlightandothercorrectionsinabsorptioncoefficientmeasurementsinthevacuumultravioletasystemsapproach
AT fahra scatteredlightandothercorrectionsinabsorptioncoefficientmeasurementsinthevacuumultravioletasystemsapproach
AT melea scatteredlightandothercorrectionsinabsorptioncoefficientmeasurementsinthevacuumultravioletasystemsapproach
AT okabeh scatteredlightandothercorrectionsinabsorptioncoefficientmeasurementsinthevacuumultravioletasystemsapproach