Varied flushing frequency and volume to prevent peripheral intravenous catheter failure: a pilot, factorial randomised controlled trial in adult medical-surgical hospital patients
BACKGROUND: Research has identified high failure rates of peripheral intravenous catheter (PIVC) and varied flushing practices. METHODS: This is a single-centre, pilot, non-masked, factorial randomised controlled trial. Participants were adults, with a PIVC of expected use ≥24 hours (n = 160), admit...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
BioMed Central
2016
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4960789/ https://www.ncbi.nlm.nih.gov/pubmed/27456005 http://dx.doi.org/10.1186/s13063-016-1470-6 |
_version_ | 1782444587967578112 |
---|---|
author | Keogh, Samantha Flynn, Julie Marsh, Nicole Mihala, Gabor Davies, Karen Rickard, Claire |
author_facet | Keogh, Samantha Flynn, Julie Marsh, Nicole Mihala, Gabor Davies, Karen Rickard, Claire |
author_sort | Keogh, Samantha |
collection | PubMed |
description | BACKGROUND: Research has identified high failure rates of peripheral intravenous catheter (PIVC) and varied flushing practices. METHODS: This is a single-centre, pilot, non-masked, factorial randomised controlled trial. Participants were adults, with a PIVC of expected use ≥24 hours (n = 160), admitted to general medical or surgical wards of a tertiary referral hospital in Queensland (Australia). Patients were randomly allocated to one of four flush groups using manually prepared syringes and 0.9 % sodium chloride: 10 mL or 3 mL flush, every 24 or 6 hours. The primary endpoint was PIVC failure, a composite measure of occlusion, infiltration, accidental dislodgement and phlebitis. RESULTS: PIVC average dwell was 3.1 days. PIVC failure rates per 1000 hours were not significantly different for the volume intervention (4.84 [3 mL] versus 7.44 [10 mL], p = 0.06, log-rank). PIVC failure rates per 1000 hours were also not significantly different for the frequency intervention (5.06 [24 hour] versus 7.34 [6 hour], p = 0.05, log-rank). Cox proportional hazard regression found neither the flushing nor frequency intervention, or their interaction (p = 0.21) to be significantly associated with PIVC failure. However, female gender (hazard ratio [HR] 2.2 [1.3–3.6], p < 0.01), insertion in hand/posterior wrist (HR 1.7 [1.0–2.7], p < 0.05) and the rate per day of PIVC access (combined flushes and medication pushes) (HR 1.2 [1.1–1.4], p < 0.01) significantly predicted PIVC failure. CONCLUSION: Neither increased flushing volume nor frequency significantly altered the risk of PIVC failure. Female gender, hand/posterior wrist placement and episodes of access (flushes and medication) may be more important. Larger, definitive trials are feasible and required. TRIAL REGISTRATION: Australian and New Zealand Clinical Trials Registry: ACTRN12615000025538. Registered on 19 January 2015. |
format | Online Article Text |
id | pubmed-4960789 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2016 |
publisher | BioMed Central |
record_format | MEDLINE/PubMed |
spelling | pubmed-49607892016-07-27 Varied flushing frequency and volume to prevent peripheral intravenous catheter failure: a pilot, factorial randomised controlled trial in adult medical-surgical hospital patients Keogh, Samantha Flynn, Julie Marsh, Nicole Mihala, Gabor Davies, Karen Rickard, Claire Trials Research BACKGROUND: Research has identified high failure rates of peripheral intravenous catheter (PIVC) and varied flushing practices. METHODS: This is a single-centre, pilot, non-masked, factorial randomised controlled trial. Participants were adults, with a PIVC of expected use ≥24 hours (n = 160), admitted to general medical or surgical wards of a tertiary referral hospital in Queensland (Australia). Patients were randomly allocated to one of four flush groups using manually prepared syringes and 0.9 % sodium chloride: 10 mL or 3 mL flush, every 24 or 6 hours. The primary endpoint was PIVC failure, a composite measure of occlusion, infiltration, accidental dislodgement and phlebitis. RESULTS: PIVC average dwell was 3.1 days. PIVC failure rates per 1000 hours were not significantly different for the volume intervention (4.84 [3 mL] versus 7.44 [10 mL], p = 0.06, log-rank). PIVC failure rates per 1000 hours were also not significantly different for the frequency intervention (5.06 [24 hour] versus 7.34 [6 hour], p = 0.05, log-rank). Cox proportional hazard regression found neither the flushing nor frequency intervention, or their interaction (p = 0.21) to be significantly associated with PIVC failure. However, female gender (hazard ratio [HR] 2.2 [1.3–3.6], p < 0.01), insertion in hand/posterior wrist (HR 1.7 [1.0–2.7], p < 0.05) and the rate per day of PIVC access (combined flushes and medication pushes) (HR 1.2 [1.1–1.4], p < 0.01) significantly predicted PIVC failure. CONCLUSION: Neither increased flushing volume nor frequency significantly altered the risk of PIVC failure. Female gender, hand/posterior wrist placement and episodes of access (flushes and medication) may be more important. Larger, definitive trials are feasible and required. TRIAL REGISTRATION: Australian and New Zealand Clinical Trials Registry: ACTRN12615000025538. Registered on 19 January 2015. BioMed Central 2016-07-26 /pmc/articles/PMC4960789/ /pubmed/27456005 http://dx.doi.org/10.1186/s13063-016-1470-6 Text en © Keogh et al. 2016 Open AccessThis article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated. |
spellingShingle | Research Keogh, Samantha Flynn, Julie Marsh, Nicole Mihala, Gabor Davies, Karen Rickard, Claire Varied flushing frequency and volume to prevent peripheral intravenous catheter failure: a pilot, factorial randomised controlled trial in adult medical-surgical hospital patients |
title | Varied flushing frequency and volume to prevent peripheral intravenous catheter failure: a pilot, factorial randomised controlled trial in adult medical-surgical hospital patients |
title_full | Varied flushing frequency and volume to prevent peripheral intravenous catheter failure: a pilot, factorial randomised controlled trial in adult medical-surgical hospital patients |
title_fullStr | Varied flushing frequency and volume to prevent peripheral intravenous catheter failure: a pilot, factorial randomised controlled trial in adult medical-surgical hospital patients |
title_full_unstemmed | Varied flushing frequency and volume to prevent peripheral intravenous catheter failure: a pilot, factorial randomised controlled trial in adult medical-surgical hospital patients |
title_short | Varied flushing frequency and volume to prevent peripheral intravenous catheter failure: a pilot, factorial randomised controlled trial in adult medical-surgical hospital patients |
title_sort | varied flushing frequency and volume to prevent peripheral intravenous catheter failure: a pilot, factorial randomised controlled trial in adult medical-surgical hospital patients |
topic | Research |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4960789/ https://www.ncbi.nlm.nih.gov/pubmed/27456005 http://dx.doi.org/10.1186/s13063-016-1470-6 |
work_keys_str_mv | AT keoghsamantha variedflushingfrequencyandvolumetopreventperipheralintravenouscatheterfailureapilotfactorialrandomisedcontrolledtrialinadultmedicalsurgicalhospitalpatients AT flynnjulie variedflushingfrequencyandvolumetopreventperipheralintravenouscatheterfailureapilotfactorialrandomisedcontrolledtrialinadultmedicalsurgicalhospitalpatients AT marshnicole variedflushingfrequencyandvolumetopreventperipheralintravenouscatheterfailureapilotfactorialrandomisedcontrolledtrialinadultmedicalsurgicalhospitalpatients AT mihalagabor variedflushingfrequencyandvolumetopreventperipheralintravenouscatheterfailureapilotfactorialrandomisedcontrolledtrialinadultmedicalsurgicalhospitalpatients AT davieskaren variedflushingfrequencyandvolumetopreventperipheralintravenouscatheterfailureapilotfactorialrandomisedcontrolledtrialinadultmedicalsurgicalhospitalpatients AT rickardclaire variedflushingfrequencyandvolumetopreventperipheralintravenouscatheterfailureapilotfactorialrandomisedcontrolledtrialinadultmedicalsurgicalhospitalpatients |