Cargando…

Varied flushing frequency and volume to prevent peripheral intravenous catheter failure: a pilot, factorial randomised controlled trial in adult medical-surgical hospital patients

BACKGROUND: Research has identified high failure rates of peripheral intravenous catheter (PIVC) and varied flushing practices. METHODS: This is a single-centre, pilot, non-masked, factorial randomised controlled trial. Participants were adults, with a PIVC of expected use ≥24 hours (n = 160), admit...

Descripción completa

Detalles Bibliográficos
Autores principales: Keogh, Samantha, Flynn, Julie, Marsh, Nicole, Mihala, Gabor, Davies, Karen, Rickard, Claire
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2016
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4960789/
https://www.ncbi.nlm.nih.gov/pubmed/27456005
http://dx.doi.org/10.1186/s13063-016-1470-6
_version_ 1782444587967578112
author Keogh, Samantha
Flynn, Julie
Marsh, Nicole
Mihala, Gabor
Davies, Karen
Rickard, Claire
author_facet Keogh, Samantha
Flynn, Julie
Marsh, Nicole
Mihala, Gabor
Davies, Karen
Rickard, Claire
author_sort Keogh, Samantha
collection PubMed
description BACKGROUND: Research has identified high failure rates of peripheral intravenous catheter (PIVC) and varied flushing practices. METHODS: This is a single-centre, pilot, non-masked, factorial randomised controlled trial. Participants were adults, with a PIVC of expected use ≥24 hours (n = 160), admitted to general medical or surgical wards of a tertiary referral hospital in Queensland (Australia). Patients were randomly allocated to one of four flush groups using manually prepared syringes and 0.9 % sodium chloride: 10 mL or 3 mL flush, every 24 or 6 hours. The primary endpoint was PIVC failure, a composite measure of occlusion, infiltration, accidental dislodgement and phlebitis. RESULTS: PIVC average dwell was 3.1 days. PIVC failure rates per 1000 hours were not significantly different for the volume intervention (4.84 [3 mL] versus 7.44 [10 mL], p = 0.06, log-rank). PIVC failure rates per 1000 hours were also not significantly different for the frequency intervention (5.06 [24 hour] versus 7.34 [6 hour], p = 0.05, log-rank). Cox proportional hazard regression found neither the flushing nor frequency intervention, or their interaction (p = 0.21) to be significantly associated with PIVC failure. However, female gender (hazard ratio [HR] 2.2 [1.3–3.6], p < 0.01), insertion in hand/posterior wrist (HR 1.7 [1.0–2.7], p < 0.05) and the rate per day of PIVC access (combined flushes and medication pushes) (HR 1.2 [1.1–1.4], p < 0.01) significantly predicted PIVC failure. CONCLUSION: Neither increased flushing volume nor frequency significantly altered the risk of PIVC failure. Female gender, hand/posterior wrist placement and episodes of access (flushes and medication) may be more important. Larger, definitive trials are feasible and required. TRIAL REGISTRATION: Australian and New Zealand Clinical Trials Registry: ACTRN12615000025538. Registered on 19 January 2015.
format Online
Article
Text
id pubmed-4960789
institution National Center for Biotechnology Information
language English
publishDate 2016
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-49607892016-07-27 Varied flushing frequency and volume to prevent peripheral intravenous catheter failure: a pilot, factorial randomised controlled trial in adult medical-surgical hospital patients Keogh, Samantha Flynn, Julie Marsh, Nicole Mihala, Gabor Davies, Karen Rickard, Claire Trials Research BACKGROUND: Research has identified high failure rates of peripheral intravenous catheter (PIVC) and varied flushing practices. METHODS: This is a single-centre, pilot, non-masked, factorial randomised controlled trial. Participants were adults, with a PIVC of expected use ≥24 hours (n = 160), admitted to general medical or surgical wards of a tertiary referral hospital in Queensland (Australia). Patients were randomly allocated to one of four flush groups using manually prepared syringes and 0.9 % sodium chloride: 10 mL or 3 mL flush, every 24 or 6 hours. The primary endpoint was PIVC failure, a composite measure of occlusion, infiltration, accidental dislodgement and phlebitis. RESULTS: PIVC average dwell was 3.1 days. PIVC failure rates per 1000 hours were not significantly different for the volume intervention (4.84 [3 mL] versus 7.44 [10 mL], p = 0.06, log-rank). PIVC failure rates per 1000 hours were also not significantly different for the frequency intervention (5.06 [24 hour] versus 7.34 [6 hour], p = 0.05, log-rank). Cox proportional hazard regression found neither the flushing nor frequency intervention, or their interaction (p = 0.21) to be significantly associated with PIVC failure. However, female gender (hazard ratio [HR] 2.2 [1.3–3.6], p < 0.01), insertion in hand/posterior wrist (HR 1.7 [1.0–2.7], p < 0.05) and the rate per day of PIVC access (combined flushes and medication pushes) (HR 1.2 [1.1–1.4], p < 0.01) significantly predicted PIVC failure. CONCLUSION: Neither increased flushing volume nor frequency significantly altered the risk of PIVC failure. Female gender, hand/posterior wrist placement and episodes of access (flushes and medication) may be more important. Larger, definitive trials are feasible and required. TRIAL REGISTRATION: Australian and New Zealand Clinical Trials Registry: ACTRN12615000025538. Registered on 19 January 2015. BioMed Central 2016-07-26 /pmc/articles/PMC4960789/ /pubmed/27456005 http://dx.doi.org/10.1186/s13063-016-1470-6 Text en © Keogh et al. 2016 Open AccessThis article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated.
spellingShingle Research
Keogh, Samantha
Flynn, Julie
Marsh, Nicole
Mihala, Gabor
Davies, Karen
Rickard, Claire
Varied flushing frequency and volume to prevent peripheral intravenous catheter failure: a pilot, factorial randomised controlled trial in adult medical-surgical hospital patients
title Varied flushing frequency and volume to prevent peripheral intravenous catheter failure: a pilot, factorial randomised controlled trial in adult medical-surgical hospital patients
title_full Varied flushing frequency and volume to prevent peripheral intravenous catheter failure: a pilot, factorial randomised controlled trial in adult medical-surgical hospital patients
title_fullStr Varied flushing frequency and volume to prevent peripheral intravenous catheter failure: a pilot, factorial randomised controlled trial in adult medical-surgical hospital patients
title_full_unstemmed Varied flushing frequency and volume to prevent peripheral intravenous catheter failure: a pilot, factorial randomised controlled trial in adult medical-surgical hospital patients
title_short Varied flushing frequency and volume to prevent peripheral intravenous catheter failure: a pilot, factorial randomised controlled trial in adult medical-surgical hospital patients
title_sort varied flushing frequency and volume to prevent peripheral intravenous catheter failure: a pilot, factorial randomised controlled trial in adult medical-surgical hospital patients
topic Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4960789/
https://www.ncbi.nlm.nih.gov/pubmed/27456005
http://dx.doi.org/10.1186/s13063-016-1470-6
work_keys_str_mv AT keoghsamantha variedflushingfrequencyandvolumetopreventperipheralintravenouscatheterfailureapilotfactorialrandomisedcontrolledtrialinadultmedicalsurgicalhospitalpatients
AT flynnjulie variedflushingfrequencyandvolumetopreventperipheralintravenouscatheterfailureapilotfactorialrandomisedcontrolledtrialinadultmedicalsurgicalhospitalpatients
AT marshnicole variedflushingfrequencyandvolumetopreventperipheralintravenouscatheterfailureapilotfactorialrandomisedcontrolledtrialinadultmedicalsurgicalhospitalpatients
AT mihalagabor variedflushingfrequencyandvolumetopreventperipheralintravenouscatheterfailureapilotfactorialrandomisedcontrolledtrialinadultmedicalsurgicalhospitalpatients
AT davieskaren variedflushingfrequencyandvolumetopreventperipheralintravenouscatheterfailureapilotfactorialrandomisedcontrolledtrialinadultmedicalsurgicalhospitalpatients
AT rickardclaire variedflushingfrequencyandvolumetopreventperipheralintravenouscatheterfailureapilotfactorialrandomisedcontrolledtrialinadultmedicalsurgicalhospitalpatients