Cargando…

The Use of Laser Guidance Reduces Fluoroscopy Time for C-Arm Cone-Beam Computed Tomography-Guided Biopsies

PURPOSE: When using laser guidance for cone-beam computed tomography (CBCT)-guided needle interventions, planned needle paths are visualized to the operator without the need to switch between entry- and progress-view during needle placement. The current study assesses the effect of laser guidance du...

Descripción completa

Detalles Bibliográficos
Autores principales: Kroes, Maarten W., van Strijen, Marco J. L., Braak, Sicco J., Hoogeveen, Yvonne L., de Lange, Frank, Schultze Kool, Leo J.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Springer US 2016
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4963440/
https://www.ncbi.nlm.nih.gov/pubmed/27094692
http://dx.doi.org/10.1007/s00270-016-1345-y
_version_ 1782444952405409792
author Kroes, Maarten W.
van Strijen, Marco J. L.
Braak, Sicco J.
Hoogeveen, Yvonne L.
de Lange, Frank
Schultze Kool, Leo J.
author_facet Kroes, Maarten W.
van Strijen, Marco J. L.
Braak, Sicco J.
Hoogeveen, Yvonne L.
de Lange, Frank
Schultze Kool, Leo J.
author_sort Kroes, Maarten W.
collection PubMed
description PURPOSE: When using laser guidance for cone-beam computed tomography (CBCT)-guided needle interventions, planned needle paths are visualized to the operator without the need to switch between entry- and progress-view during needle placement. The current study assesses the effect of laser guidance during CBCT-guided biopsies on fluoroscopy and procedure times. MATERIALS AND METHODS: Prospective data from 15 CBCT-guided biopsies of 8–65 mm thoracic and abdominal lesions assisted by a ceiling-mounted laser guidance technique were compared to retrospective data of 36 performed CBCT-guided biopsies of lesions >20 mm using the freehand technique. Fluoroscopy time, procedure time, and number of CBCT-scans were recorded. All data are presented as median (ranges). RESULTS: For biopsies using the freehand technique, more fluoroscopy time was necessary to guide the needle onto the target, 165 s (83–333 s) compared to 87 s (44–190 s) for laser guidance (p < 0.001). Procedure times were shorter for freehand-guided biopsies, 24 min versus 30 min for laser guidance (p < 0.001). CONCLUSION: The use of laser guidance during CBCT-guided biopsies significantly reduces fluoroscopy time.
format Online
Article
Text
id pubmed-4963440
institution National Center for Biotechnology Information
language English
publishDate 2016
publisher Springer US
record_format MEDLINE/PubMed
spelling pubmed-49634402016-08-10 The Use of Laser Guidance Reduces Fluoroscopy Time for C-Arm Cone-Beam Computed Tomography-Guided Biopsies Kroes, Maarten W. van Strijen, Marco J. L. Braak, Sicco J. Hoogeveen, Yvonne L. de Lange, Frank Schultze Kool, Leo J. Cardiovasc Intervent Radiol Technical Note PURPOSE: When using laser guidance for cone-beam computed tomography (CBCT)-guided needle interventions, planned needle paths are visualized to the operator without the need to switch between entry- and progress-view during needle placement. The current study assesses the effect of laser guidance during CBCT-guided biopsies on fluoroscopy and procedure times. MATERIALS AND METHODS: Prospective data from 15 CBCT-guided biopsies of 8–65 mm thoracic and abdominal lesions assisted by a ceiling-mounted laser guidance technique were compared to retrospective data of 36 performed CBCT-guided biopsies of lesions >20 mm using the freehand technique. Fluoroscopy time, procedure time, and number of CBCT-scans were recorded. All data are presented as median (ranges). RESULTS: For biopsies using the freehand technique, more fluoroscopy time was necessary to guide the needle onto the target, 165 s (83–333 s) compared to 87 s (44–190 s) for laser guidance (p < 0.001). Procedure times were shorter for freehand-guided biopsies, 24 min versus 30 min for laser guidance (p < 0.001). CONCLUSION: The use of laser guidance during CBCT-guided biopsies significantly reduces fluoroscopy time. Springer US 2016-04-19 2016 /pmc/articles/PMC4963440/ /pubmed/27094692 http://dx.doi.org/10.1007/s00270-016-1345-y Text en © The Author(s) 2016 Open AccessThis article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made.
spellingShingle Technical Note
Kroes, Maarten W.
van Strijen, Marco J. L.
Braak, Sicco J.
Hoogeveen, Yvonne L.
de Lange, Frank
Schultze Kool, Leo J.
The Use of Laser Guidance Reduces Fluoroscopy Time for C-Arm Cone-Beam Computed Tomography-Guided Biopsies
title The Use of Laser Guidance Reduces Fluoroscopy Time for C-Arm Cone-Beam Computed Tomography-Guided Biopsies
title_full The Use of Laser Guidance Reduces Fluoroscopy Time for C-Arm Cone-Beam Computed Tomography-Guided Biopsies
title_fullStr The Use of Laser Guidance Reduces Fluoroscopy Time for C-Arm Cone-Beam Computed Tomography-Guided Biopsies
title_full_unstemmed The Use of Laser Guidance Reduces Fluoroscopy Time for C-Arm Cone-Beam Computed Tomography-Guided Biopsies
title_short The Use of Laser Guidance Reduces Fluoroscopy Time for C-Arm Cone-Beam Computed Tomography-Guided Biopsies
title_sort use of laser guidance reduces fluoroscopy time for c-arm cone-beam computed tomography-guided biopsies
topic Technical Note
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4963440/
https://www.ncbi.nlm.nih.gov/pubmed/27094692
http://dx.doi.org/10.1007/s00270-016-1345-y
work_keys_str_mv AT kroesmaartenw theuseoflaserguidancereducesfluoroscopytimeforcarmconebeamcomputedtomographyguidedbiopsies
AT vanstrijenmarcojl theuseoflaserguidancereducesfluoroscopytimeforcarmconebeamcomputedtomographyguidedbiopsies
AT braaksiccoj theuseoflaserguidancereducesfluoroscopytimeforcarmconebeamcomputedtomographyguidedbiopsies
AT hoogeveenyvonnel theuseoflaserguidancereducesfluoroscopytimeforcarmconebeamcomputedtomographyguidedbiopsies
AT delangefrank theuseoflaserguidancereducesfluoroscopytimeforcarmconebeamcomputedtomographyguidedbiopsies
AT schultzekoolleoj theuseoflaserguidancereducesfluoroscopytimeforcarmconebeamcomputedtomographyguidedbiopsies
AT kroesmaartenw useoflaserguidancereducesfluoroscopytimeforcarmconebeamcomputedtomographyguidedbiopsies
AT vanstrijenmarcojl useoflaserguidancereducesfluoroscopytimeforcarmconebeamcomputedtomographyguidedbiopsies
AT braaksiccoj useoflaserguidancereducesfluoroscopytimeforcarmconebeamcomputedtomographyguidedbiopsies
AT hoogeveenyvonnel useoflaserguidancereducesfluoroscopytimeforcarmconebeamcomputedtomographyguidedbiopsies
AT delangefrank useoflaserguidancereducesfluoroscopytimeforcarmconebeamcomputedtomographyguidedbiopsies
AT schultzekoolleoj useoflaserguidancereducesfluoroscopytimeforcarmconebeamcomputedtomographyguidedbiopsies