Cargando…

flowVS: channel-specific variance stabilization in flow cytometry

BACKGROUND: Comparing phenotypes of heterogeneous cell populations from multiple biological conditions is at the heart of scientific discovery based on flow cytometry (FC). When the biological signal is measured by the average expression of a biomarker, standard statistical methods require that vari...

Descripción completa

Detalles Bibliográficos
Autores principales: Azad, Ariful, Rajwa, Bartek, Pothen, Alex
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2016
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4964071/
https://www.ncbi.nlm.nih.gov/pubmed/27465477
http://dx.doi.org/10.1186/s12859-016-1083-9
_version_ 1782445039877619712
author Azad, Ariful
Rajwa, Bartek
Pothen, Alex
author_facet Azad, Ariful
Rajwa, Bartek
Pothen, Alex
author_sort Azad, Ariful
collection PubMed
description BACKGROUND: Comparing phenotypes of heterogeneous cell populations from multiple biological conditions is at the heart of scientific discovery based on flow cytometry (FC). When the biological signal is measured by the average expression of a biomarker, standard statistical methods require that variance be approximately stabilized in populations to be compared. Since the mean and variance of a cell population are often correlated in fluorescence-based FC measurements, a preprocessing step is needed to stabilize the within-population variances. RESULTS: We present a variance-stabilization algorithm, called flowVS, that removes the mean-variance correlations from cell populations identified in each fluorescence channel. flowVS transforms each channel from all samples of a data set by the inverse hyperbolic sine (asinh) transformation. For each channel, the parameters of the transformation are optimally selected by Bartlett’s likelihood-ratio test so that the populations attain homogeneous variances. The optimum parameters are then used to transform the corresponding channels in every sample. flowVS is therefore an explicit variance-stabilization method that stabilizes within-population variances in each channel by evaluating the homoskedasticity of clusters with a likelihood-ratio test. With two publicly available datasets, we show that flowVS removes the mean-variance dependence from raw FC data and makes the within-population variance relatively homogeneous. We demonstrate that alternative transformation techniques such as flowTrans, flowScape, logicle, and FCSTrans might not stabilize variance. Besides flow cytometry, flowVS can also be applied to stabilize variance in microarray data. With a publicly available data set we demonstrate that flowVS performs as well as the VSN software, a state-of-the-art approach developed for microarrays. CONCLUSIONS: The homogeneity of variance in cell populations across FC samples is desirable when extracting features uniformly and comparing cell populations with different levels of marker expressions. The newly developed flowVS algorithm solves the variance-stabilization problem in FC and microarrays by optimally transforming data with the help of Bartlett’s likelihood-ratio test. On two publicly available FC datasets, flowVS stabilizes within-population variances more evenly than the available transformation and normalization techniques. flowVS-based variance stabilization can help in performing comparison and alignment of phenotypically identical cell populations across different samples. flowVS and the datasets used in this paper are publicly available in Bioconductor.
format Online
Article
Text
id pubmed-4964071
institution National Center for Biotechnology Information
language English
publishDate 2016
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-49640712016-08-02 flowVS: channel-specific variance stabilization in flow cytometry Azad, Ariful Rajwa, Bartek Pothen, Alex BMC Bioinformatics Research Article BACKGROUND: Comparing phenotypes of heterogeneous cell populations from multiple biological conditions is at the heart of scientific discovery based on flow cytometry (FC). When the biological signal is measured by the average expression of a biomarker, standard statistical methods require that variance be approximately stabilized in populations to be compared. Since the mean and variance of a cell population are often correlated in fluorescence-based FC measurements, a preprocessing step is needed to stabilize the within-population variances. RESULTS: We present a variance-stabilization algorithm, called flowVS, that removes the mean-variance correlations from cell populations identified in each fluorescence channel. flowVS transforms each channel from all samples of a data set by the inverse hyperbolic sine (asinh) transformation. For each channel, the parameters of the transformation are optimally selected by Bartlett’s likelihood-ratio test so that the populations attain homogeneous variances. The optimum parameters are then used to transform the corresponding channels in every sample. flowVS is therefore an explicit variance-stabilization method that stabilizes within-population variances in each channel by evaluating the homoskedasticity of clusters with a likelihood-ratio test. With two publicly available datasets, we show that flowVS removes the mean-variance dependence from raw FC data and makes the within-population variance relatively homogeneous. We demonstrate that alternative transformation techniques such as flowTrans, flowScape, logicle, and FCSTrans might not stabilize variance. Besides flow cytometry, flowVS can also be applied to stabilize variance in microarray data. With a publicly available data set we demonstrate that flowVS performs as well as the VSN software, a state-of-the-art approach developed for microarrays. CONCLUSIONS: The homogeneity of variance in cell populations across FC samples is desirable when extracting features uniformly and comparing cell populations with different levels of marker expressions. The newly developed flowVS algorithm solves the variance-stabilization problem in FC and microarrays by optimally transforming data with the help of Bartlett’s likelihood-ratio test. On two publicly available FC datasets, flowVS stabilizes within-population variances more evenly than the available transformation and normalization techniques. flowVS-based variance stabilization can help in performing comparison and alignment of phenotypically identical cell populations across different samples. flowVS and the datasets used in this paper are publicly available in Bioconductor. BioMed Central 2016-07-28 /pmc/articles/PMC4964071/ /pubmed/27465477 http://dx.doi.org/10.1186/s12859-016-1083-9 Text en © Azad et al. 2016 Open Access This article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated.
spellingShingle Research Article
Azad, Ariful
Rajwa, Bartek
Pothen, Alex
flowVS: channel-specific variance stabilization in flow cytometry
title flowVS: channel-specific variance stabilization in flow cytometry
title_full flowVS: channel-specific variance stabilization in flow cytometry
title_fullStr flowVS: channel-specific variance stabilization in flow cytometry
title_full_unstemmed flowVS: channel-specific variance stabilization in flow cytometry
title_short flowVS: channel-specific variance stabilization in flow cytometry
title_sort flowvs: channel-specific variance stabilization in flow cytometry
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4964071/
https://www.ncbi.nlm.nih.gov/pubmed/27465477
http://dx.doi.org/10.1186/s12859-016-1083-9
work_keys_str_mv AT azadariful flowvschannelspecificvariancestabilizationinflowcytometry
AT rajwabartek flowvschannelspecificvariancestabilizationinflowcytometry
AT pothenalex flowvschannelspecificvariancestabilizationinflowcytometry