Cargando…
Endovascular Repair Using Suture-Mediated Closure Devices and Balloon Tamponade following Inadvertent Subclavian Artery Catheterization with Large-Caliber Hemodialysis Catheter
Accidental subclavian artery cannulation is an uncommon but potentially serious complication of central venous catheterization. Removal of a catheter inadvertently placed in the subclavian artery can lead to substantial bleeding, as achieving hemostasis in this area through manual compression presen...
Autores principales: | , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
The Korean Society of Cardiology
2016
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4965441/ https://www.ncbi.nlm.nih.gov/pubmed/27482271 http://dx.doi.org/10.4070/kcj.2016.46.4.584 |
_version_ | 1782445253281710080 |
---|---|
author | Park, Taek Kyu Yang, Jeong Hoon Choi, Seung-Hyuk |
author_facet | Park, Taek Kyu Yang, Jeong Hoon Choi, Seung-Hyuk |
author_sort | Park, Taek Kyu |
collection | PubMed |
description | Accidental subclavian artery cannulation is an uncommon but potentially serious complication of central venous catheterization. Removal of a catheter inadvertently placed in the subclavian artery can lead to substantial bleeding, as achieving hemostasis in this area through manual compression presents considerable difficulty. Additionally, surgical treatment might be unsuitable for high-risk patients due to comorbidities. Here, we report a case of an inadvertently-inserted 11.5-French hemodialysis catheter in the subclavian artery during internal jugular venous catheterization. We performed percutaneous closure of the subclavian artery using three 6-French Perclose Proglide® devices with a balloon tamponade in the proximal part of the subclavian artery. Closure was completed without embolic neurological complications. |
format | Online Article Text |
id | pubmed-4965441 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2016 |
publisher | The Korean Society of Cardiology |
record_format | MEDLINE/PubMed |
spelling | pubmed-49654412016-08-01 Endovascular Repair Using Suture-Mediated Closure Devices and Balloon Tamponade following Inadvertent Subclavian Artery Catheterization with Large-Caliber Hemodialysis Catheter Park, Taek Kyu Yang, Jeong Hoon Choi, Seung-Hyuk Korean Circ J Case Report Accidental subclavian artery cannulation is an uncommon but potentially serious complication of central venous catheterization. Removal of a catheter inadvertently placed in the subclavian artery can lead to substantial bleeding, as achieving hemostasis in this area through manual compression presents considerable difficulty. Additionally, surgical treatment might be unsuitable for high-risk patients due to comorbidities. Here, we report a case of an inadvertently-inserted 11.5-French hemodialysis catheter in the subclavian artery during internal jugular venous catheterization. We performed percutaneous closure of the subclavian artery using three 6-French Perclose Proglide® devices with a balloon tamponade in the proximal part of the subclavian artery. Closure was completed without embolic neurological complications. The Korean Society of Cardiology 2016-07 2016-07-21 /pmc/articles/PMC4965441/ /pubmed/27482271 http://dx.doi.org/10.4070/kcj.2016.46.4.584 Text en Copyright © 2016 The Korean Society of Cardiology http://creativecommons.org/licenses/by-nc/3.0/ This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/3.0/) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Case Report Park, Taek Kyu Yang, Jeong Hoon Choi, Seung-Hyuk Endovascular Repair Using Suture-Mediated Closure Devices and Balloon Tamponade following Inadvertent Subclavian Artery Catheterization with Large-Caliber Hemodialysis Catheter |
title | Endovascular Repair Using Suture-Mediated Closure Devices and Balloon Tamponade following Inadvertent Subclavian Artery Catheterization with Large-Caliber Hemodialysis Catheter |
title_full | Endovascular Repair Using Suture-Mediated Closure Devices and Balloon Tamponade following Inadvertent Subclavian Artery Catheterization with Large-Caliber Hemodialysis Catheter |
title_fullStr | Endovascular Repair Using Suture-Mediated Closure Devices and Balloon Tamponade following Inadvertent Subclavian Artery Catheterization with Large-Caliber Hemodialysis Catheter |
title_full_unstemmed | Endovascular Repair Using Suture-Mediated Closure Devices and Balloon Tamponade following Inadvertent Subclavian Artery Catheterization with Large-Caliber Hemodialysis Catheter |
title_short | Endovascular Repair Using Suture-Mediated Closure Devices and Balloon Tamponade following Inadvertent Subclavian Artery Catheterization with Large-Caliber Hemodialysis Catheter |
title_sort | endovascular repair using suture-mediated closure devices and balloon tamponade following inadvertent subclavian artery catheterization with large-caliber hemodialysis catheter |
topic | Case Report |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4965441/ https://www.ncbi.nlm.nih.gov/pubmed/27482271 http://dx.doi.org/10.4070/kcj.2016.46.4.584 |
work_keys_str_mv | AT parktaekkyu endovascularrepairusingsuturemediatedclosuredevicesandballoontamponadefollowinginadvertentsubclavianarterycatheterizationwithlargecaliberhemodialysiscatheter AT yangjeonghoon endovascularrepairusingsuturemediatedclosuredevicesandballoontamponadefollowinginadvertentsubclavianarterycatheterizationwithlargecaliberhemodialysiscatheter AT choiseunghyuk endovascularrepairusingsuturemediatedclosuredevicesandballoontamponadefollowinginadvertentsubclavianarterycatheterizationwithlargecaliberhemodialysiscatheter |