Cargando…

Endovascular Repair Using Suture-Mediated Closure Devices and Balloon Tamponade following Inadvertent Subclavian Artery Catheterization with Large-Caliber Hemodialysis Catheter

Accidental subclavian artery cannulation is an uncommon but potentially serious complication of central venous catheterization. Removal of a catheter inadvertently placed in the subclavian artery can lead to substantial bleeding, as achieving hemostasis in this area through manual compression presen...

Descripción completa

Detalles Bibliográficos
Autores principales: Park, Taek Kyu, Yang, Jeong Hoon, Choi, Seung-Hyuk
Formato: Online Artículo Texto
Lenguaje:English
Publicado: The Korean Society of Cardiology 2016
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4965441/
https://www.ncbi.nlm.nih.gov/pubmed/27482271
http://dx.doi.org/10.4070/kcj.2016.46.4.584
_version_ 1782445253281710080
author Park, Taek Kyu
Yang, Jeong Hoon
Choi, Seung-Hyuk
author_facet Park, Taek Kyu
Yang, Jeong Hoon
Choi, Seung-Hyuk
author_sort Park, Taek Kyu
collection PubMed
description Accidental subclavian artery cannulation is an uncommon but potentially serious complication of central venous catheterization. Removal of a catheter inadvertently placed in the subclavian artery can lead to substantial bleeding, as achieving hemostasis in this area through manual compression presents considerable difficulty. Additionally, surgical treatment might be unsuitable for high-risk patients due to comorbidities. Here, we report a case of an inadvertently-inserted 11.5-French hemodialysis catheter in the subclavian artery during internal jugular venous catheterization. We performed percutaneous closure of the subclavian artery using three 6-French Perclose Proglide® devices with a balloon tamponade in the proximal part of the subclavian artery. Closure was completed without embolic neurological complications.
format Online
Article
Text
id pubmed-4965441
institution National Center for Biotechnology Information
language English
publishDate 2016
publisher The Korean Society of Cardiology
record_format MEDLINE/PubMed
spelling pubmed-49654412016-08-01 Endovascular Repair Using Suture-Mediated Closure Devices and Balloon Tamponade following Inadvertent Subclavian Artery Catheterization with Large-Caliber Hemodialysis Catheter Park, Taek Kyu Yang, Jeong Hoon Choi, Seung-Hyuk Korean Circ J Case Report Accidental subclavian artery cannulation is an uncommon but potentially serious complication of central venous catheterization. Removal of a catheter inadvertently placed in the subclavian artery can lead to substantial bleeding, as achieving hemostasis in this area through manual compression presents considerable difficulty. Additionally, surgical treatment might be unsuitable for high-risk patients due to comorbidities. Here, we report a case of an inadvertently-inserted 11.5-French hemodialysis catheter in the subclavian artery during internal jugular venous catheterization. We performed percutaneous closure of the subclavian artery using three 6-French Perclose Proglide® devices with a balloon tamponade in the proximal part of the subclavian artery. Closure was completed without embolic neurological complications. The Korean Society of Cardiology 2016-07 2016-07-21 /pmc/articles/PMC4965441/ /pubmed/27482271 http://dx.doi.org/10.4070/kcj.2016.46.4.584 Text en Copyright © 2016 The Korean Society of Cardiology http://creativecommons.org/licenses/by-nc/3.0/ This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/3.0/) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Case Report
Park, Taek Kyu
Yang, Jeong Hoon
Choi, Seung-Hyuk
Endovascular Repair Using Suture-Mediated Closure Devices and Balloon Tamponade following Inadvertent Subclavian Artery Catheterization with Large-Caliber Hemodialysis Catheter
title Endovascular Repair Using Suture-Mediated Closure Devices and Balloon Tamponade following Inadvertent Subclavian Artery Catheterization with Large-Caliber Hemodialysis Catheter
title_full Endovascular Repair Using Suture-Mediated Closure Devices and Balloon Tamponade following Inadvertent Subclavian Artery Catheterization with Large-Caliber Hemodialysis Catheter
title_fullStr Endovascular Repair Using Suture-Mediated Closure Devices and Balloon Tamponade following Inadvertent Subclavian Artery Catheterization with Large-Caliber Hemodialysis Catheter
title_full_unstemmed Endovascular Repair Using Suture-Mediated Closure Devices and Balloon Tamponade following Inadvertent Subclavian Artery Catheterization with Large-Caliber Hemodialysis Catheter
title_short Endovascular Repair Using Suture-Mediated Closure Devices and Balloon Tamponade following Inadvertent Subclavian Artery Catheterization with Large-Caliber Hemodialysis Catheter
title_sort endovascular repair using suture-mediated closure devices and balloon tamponade following inadvertent subclavian artery catheterization with large-caliber hemodialysis catheter
topic Case Report
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4965441/
https://www.ncbi.nlm.nih.gov/pubmed/27482271
http://dx.doi.org/10.4070/kcj.2016.46.4.584
work_keys_str_mv AT parktaekkyu endovascularrepairusingsuturemediatedclosuredevicesandballoontamponadefollowinginadvertentsubclavianarterycatheterizationwithlargecaliberhemodialysiscatheter
AT yangjeonghoon endovascularrepairusingsuturemediatedclosuredevicesandballoontamponadefollowinginadvertentsubclavianarterycatheterizationwithlargecaliberhemodialysiscatheter
AT choiseunghyuk endovascularrepairusingsuturemediatedclosuredevicesandballoontamponadefollowinginadvertentsubclavianarterycatheterizationwithlargecaliberhemodialysiscatheter