Cargando…

Evaluation of Anterior Segment Parameter Changes Using the Sirius after Uneventful Phacoemulsification

PURPOSE: To investigate changes in anterior chamber depth (ACD), corneal volume (CV), anterior chamber angle (ACA), anterior chamber volume (ACV), central corneal thickness (CCT), horizontal visible iris diameter (HVID), pupil diameter (PD), and intraocular pressure (IOP) after uneventful phacoemuls...

Descripción completa

Detalles Bibliográficos
Autores principales: Şimşek, Ali, Bilgin, Burak, Çapkın, Musa, Bilak, Şemsettin, Güler, Mete, Reyhan, Ali Hakim
Formato: Online Artículo Texto
Lenguaje:English
Publicado: The Korean Ophthalmological Society 2016
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4965599/
https://www.ncbi.nlm.nih.gov/pubmed/27478351
http://dx.doi.org/10.3341/kjo.2016.30.4.251
_version_ 1782445278666686464
author Şimşek, Ali
Bilgin, Burak
Çapkın, Musa
Bilak, Şemsettin
Güler, Mete
Reyhan, Ali Hakim
author_facet Şimşek, Ali
Bilgin, Burak
Çapkın, Musa
Bilak, Şemsettin
Güler, Mete
Reyhan, Ali Hakim
author_sort Şimşek, Ali
collection PubMed
description PURPOSE: To investigate changes in anterior chamber depth (ACD), corneal volume (CV), anterior chamber angle (ACA), anterior chamber volume (ACV), central corneal thickness (CCT), horizontal visible iris diameter (HVID), pupil diameter (PD), and intraocular pressure (IOP) after uneventful phacoemulsification cataract surgery with intraocular lens implantation. METHODS: A total of 132 eyes of 132 patients (87 men and 45 women) that underwent uneventful phacoemulsification cataract surgery and intraocular lens implantation were prospectively studied. The mean age of the patients was 63.68 ± 12.51 years. All patients were evaluated preoperatively and at 1 month postoperatively with the Sirius 3D Rotating Scheimpflug camera topography system. The ACD, CV, ACA, ACV, CCT, HVID, and PD measurements were recorded. IOP was measured using the Goldmann applanation tonometer, which was corrected for CCT of the Sirius device using Ehlers' formula. RESULTS: The preoperative mean ACD, ACV, ACA, CCT, CV, PD, HVID, and IOP were 2.79 ± 0.45 mm, 124.73 ± 25.72 mm(3), 42.09 ± 7.49(0), 523.87 ± 41.97 microns, 55.37 ± 4.89 mm(3), 3.98 ± 1.23 mm, 11.72 ± 0.67 mm, and 14.74 ± 2.59 mmHg, respectively. Three months postoperatively, the mean ACD, ACV, ACA, CCT, CV, PD, HVID, and IOP were 3.45 ± 0.6 mm, 162.52 ± 23.79 mm(3), 51.46 ± 5.63(0), 526.21 ± 44.45 microns, 56.23 ± 5.12 mm(3), 2.87 ± 0.45 mm, 11.91 ± 0.75 mm, and 12.02 ± 1.83 mmHg, respectively. There was a statistically significant increase in mean postoperative ACD, ACV, ACA, CV, and HVID compared with the corresponding preoperative values (p < 0.05). CCT remained stable after surgery. Postoperative PD and IOP were significantly decreased compared to corresponding preoperative values (p < 0.05). CONCLUSIONS: Preoperative measurements by the Sirius 3D Rotating Scheimpflug camera topography system might help surgeons to predict postoperative changes resulting from phacoemulsification and intraocular lens implantation. This is a noncontact, noninvasive, and comfortable system for patients that is highly reliable and repeatable for anterior segment measurements.
format Online
Article
Text
id pubmed-4965599
institution National Center for Biotechnology Information
language English
publishDate 2016
publisher The Korean Ophthalmological Society
record_format MEDLINE/PubMed
spelling pubmed-49655992016-08-01 Evaluation of Anterior Segment Parameter Changes Using the Sirius after Uneventful Phacoemulsification Şimşek, Ali Bilgin, Burak Çapkın, Musa Bilak, Şemsettin Güler, Mete Reyhan, Ali Hakim Korean J Ophthalmol Original Article PURPOSE: To investigate changes in anterior chamber depth (ACD), corneal volume (CV), anterior chamber angle (ACA), anterior chamber volume (ACV), central corneal thickness (CCT), horizontal visible iris diameter (HVID), pupil diameter (PD), and intraocular pressure (IOP) after uneventful phacoemulsification cataract surgery with intraocular lens implantation. METHODS: A total of 132 eyes of 132 patients (87 men and 45 women) that underwent uneventful phacoemulsification cataract surgery and intraocular lens implantation were prospectively studied. The mean age of the patients was 63.68 ± 12.51 years. All patients were evaluated preoperatively and at 1 month postoperatively with the Sirius 3D Rotating Scheimpflug camera topography system. The ACD, CV, ACA, ACV, CCT, HVID, and PD measurements were recorded. IOP was measured using the Goldmann applanation tonometer, which was corrected for CCT of the Sirius device using Ehlers' formula. RESULTS: The preoperative mean ACD, ACV, ACA, CCT, CV, PD, HVID, and IOP were 2.79 ± 0.45 mm, 124.73 ± 25.72 mm(3), 42.09 ± 7.49(0), 523.87 ± 41.97 microns, 55.37 ± 4.89 mm(3), 3.98 ± 1.23 mm, 11.72 ± 0.67 mm, and 14.74 ± 2.59 mmHg, respectively. Three months postoperatively, the mean ACD, ACV, ACA, CCT, CV, PD, HVID, and IOP were 3.45 ± 0.6 mm, 162.52 ± 23.79 mm(3), 51.46 ± 5.63(0), 526.21 ± 44.45 microns, 56.23 ± 5.12 mm(3), 2.87 ± 0.45 mm, 11.91 ± 0.75 mm, and 12.02 ± 1.83 mmHg, respectively. There was a statistically significant increase in mean postoperative ACD, ACV, ACA, CV, and HVID compared with the corresponding preoperative values (p < 0.05). CCT remained stable after surgery. Postoperative PD and IOP were significantly decreased compared to corresponding preoperative values (p < 0.05). CONCLUSIONS: Preoperative measurements by the Sirius 3D Rotating Scheimpflug camera topography system might help surgeons to predict postoperative changes resulting from phacoemulsification and intraocular lens implantation. This is a noncontact, noninvasive, and comfortable system for patients that is highly reliable and repeatable for anterior segment measurements. The Korean Ophthalmological Society 2016-08 2016-07-21 /pmc/articles/PMC4965599/ /pubmed/27478351 http://dx.doi.org/10.3341/kjo.2016.30.4.251 Text en © 2016 The Korean Ophthalmological Society http://creativecommons.org/licenses/by-nc/3.0/ This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/3.0/) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Original Article
Şimşek, Ali
Bilgin, Burak
Çapkın, Musa
Bilak, Şemsettin
Güler, Mete
Reyhan, Ali Hakim
Evaluation of Anterior Segment Parameter Changes Using the Sirius after Uneventful Phacoemulsification
title Evaluation of Anterior Segment Parameter Changes Using the Sirius after Uneventful Phacoemulsification
title_full Evaluation of Anterior Segment Parameter Changes Using the Sirius after Uneventful Phacoemulsification
title_fullStr Evaluation of Anterior Segment Parameter Changes Using the Sirius after Uneventful Phacoemulsification
title_full_unstemmed Evaluation of Anterior Segment Parameter Changes Using the Sirius after Uneventful Phacoemulsification
title_short Evaluation of Anterior Segment Parameter Changes Using the Sirius after Uneventful Phacoemulsification
title_sort evaluation of anterior segment parameter changes using the sirius after uneventful phacoemulsification
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4965599/
https://www.ncbi.nlm.nih.gov/pubmed/27478351
http://dx.doi.org/10.3341/kjo.2016.30.4.251
work_keys_str_mv AT simsekali evaluationofanteriorsegmentparameterchangesusingthesiriusafteruneventfulphacoemulsification
AT bilginburak evaluationofanteriorsegmentparameterchangesusingthesiriusafteruneventfulphacoemulsification
AT capkınmusa evaluationofanteriorsegmentparameterchangesusingthesiriusafteruneventfulphacoemulsification
AT bilaksemsettin evaluationofanteriorsegmentparameterchangesusingthesiriusafteruneventfulphacoemulsification
AT gulermete evaluationofanteriorsegmentparameterchangesusingthesiriusafteruneventfulphacoemulsification
AT reyhanalihakim evaluationofanteriorsegmentparameterchangesusingthesiriusafteruneventfulphacoemulsification