Cargando…

Patient-specific instrumentation does not improve radiographic alignment or clinical outcomes after total knee arthroplasty: A meta-analysis

BACKGROUND AND PURPOSE: Patient-specific instrumentation (PSI) for total knee arthroplasty (TKA) has been introduced to improve alignment and reduce outliers, increase efficiency, and reduce operation time. In order to improve our understanding of the outcomes of patient-specific instrumentation, we...

Descripción completa

Detalles Bibliográficos
Autores principales: Huijbregts, Henricus J T A M, Khan, Riaz J K, Sorensen, Emma, Fick, Daniel P, Haebich, Samantha
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Taylor & Francis 2016
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4967282/
https://www.ncbi.nlm.nih.gov/pubmed/27249110
http://dx.doi.org/10.1080/17453674.2016.1193799
_version_ 1782445492003667968
author Huijbregts, Henricus J T A M
Khan, Riaz J K
Sorensen, Emma
Fick, Daniel P
Haebich, Samantha
author_facet Huijbregts, Henricus J T A M
Khan, Riaz J K
Sorensen, Emma
Fick, Daniel P
Haebich, Samantha
author_sort Huijbregts, Henricus J T A M
collection PubMed
description BACKGROUND AND PURPOSE: Patient-specific instrumentation (PSI) for total knee arthroplasty (TKA) has been introduced to improve alignment and reduce outliers, increase efficiency, and reduce operation time. In order to improve our understanding of the outcomes of patient-specific instrumentation, we conducted a meta-analysis. PATIENTS AND METHODS: We identified randomized and quasi-randomized controlled trials (RCTs) comparing patient-specific and conventional instrumentation in TKA. Weighted mean differences and risk ratios were determined for radiographic accuracy, operation time, hospital stay, blood loss, number of surgical trays required, and patient-reported outcome measures. RESULTS: 21 RCTs involving 1,587 TKAs were included. Patient-specific instrumentation resulted in slightly more accurate hip-knee-ankle axis (0.3°), coronal femoral alignment (0.3°, femoral flexion (0.9°), tibial slope (0.7°), and femoral component rotation (0.5°). The risk ratio of a coronal plane outlier (> 3° deviation of chosen target) for the tibial component was statistically significantly increased in the PSI group (RR =1.64). No significance was found for other radiographic measures. Operation time, blood loss, and transfusion rate were similar. Hospital stay was significantly shortened, by approximately 8 h, and the number of surgical trays used decreased by 4 in the PSI group. Knee Society scores and Oxford knee scores were similar. INTERPRETATION: Patient-specific instrumentation does not result in clinically meaningful improvement in alignment, fewer outliers, or better early patient-reported outcome measures. Efficiency is improved by reducing the number of trays used, but PSI does not reduce operation time.
format Online
Article
Text
id pubmed-4967282
institution National Center for Biotechnology Information
language English
publishDate 2016
publisher Taylor & Francis
record_format MEDLINE/PubMed
spelling pubmed-49672822017-01-11 Patient-specific instrumentation does not improve radiographic alignment or clinical outcomes after total knee arthroplasty: A meta-analysis Huijbregts, Henricus J T A M Khan, Riaz J K Sorensen, Emma Fick, Daniel P Haebich, Samantha Acta Orthop Articles BACKGROUND AND PURPOSE: Patient-specific instrumentation (PSI) for total knee arthroplasty (TKA) has been introduced to improve alignment and reduce outliers, increase efficiency, and reduce operation time. In order to improve our understanding of the outcomes of patient-specific instrumentation, we conducted a meta-analysis. PATIENTS AND METHODS: We identified randomized and quasi-randomized controlled trials (RCTs) comparing patient-specific and conventional instrumentation in TKA. Weighted mean differences and risk ratios were determined for radiographic accuracy, operation time, hospital stay, blood loss, number of surgical trays required, and patient-reported outcome measures. RESULTS: 21 RCTs involving 1,587 TKAs were included. Patient-specific instrumentation resulted in slightly more accurate hip-knee-ankle axis (0.3°), coronal femoral alignment (0.3°, femoral flexion (0.9°), tibial slope (0.7°), and femoral component rotation (0.5°). The risk ratio of a coronal plane outlier (> 3° deviation of chosen target) for the tibial component was statistically significantly increased in the PSI group (RR =1.64). No significance was found for other radiographic measures. Operation time, blood loss, and transfusion rate were similar. Hospital stay was significantly shortened, by approximately 8 h, and the number of surgical trays used decreased by 4 in the PSI group. Knee Society scores and Oxford knee scores were similar. INTERPRETATION: Patient-specific instrumentation does not result in clinically meaningful improvement in alignment, fewer outliers, or better early patient-reported outcome measures. Efficiency is improved by reducing the number of trays used, but PSI does not reduce operation time. Taylor & Francis 2016-08 2016-06-01 /pmc/articles/PMC4967282/ /pubmed/27249110 http://dx.doi.org/10.1080/17453674.2016.1193799 Text en © 2016 The Author(s). Published by Taylor & Francis on behalf of the Nordic Orthopedic Federation. https://creativecommons.org/licenses/by-nc/3.0 This is an Open Access article distributed under the terms of the Creative Commons Attribution-Non-Commercial License (https://creativecommons.org/licenses/by-nc/3.0)
spellingShingle Articles
Huijbregts, Henricus J T A M
Khan, Riaz J K
Sorensen, Emma
Fick, Daniel P
Haebich, Samantha
Patient-specific instrumentation does not improve radiographic alignment or clinical outcomes after total knee arthroplasty: A meta-analysis
title Patient-specific instrumentation does not improve radiographic alignment or clinical outcomes after total knee arthroplasty: A meta-analysis
title_full Patient-specific instrumentation does not improve radiographic alignment or clinical outcomes after total knee arthroplasty: A meta-analysis
title_fullStr Patient-specific instrumentation does not improve radiographic alignment or clinical outcomes after total knee arthroplasty: A meta-analysis
title_full_unstemmed Patient-specific instrumentation does not improve radiographic alignment or clinical outcomes after total knee arthroplasty: A meta-analysis
title_short Patient-specific instrumentation does not improve radiographic alignment or clinical outcomes after total knee arthroplasty: A meta-analysis
title_sort patient-specific instrumentation does not improve radiographic alignment or clinical outcomes after total knee arthroplasty: a meta-analysis
topic Articles
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4967282/
https://www.ncbi.nlm.nih.gov/pubmed/27249110
http://dx.doi.org/10.1080/17453674.2016.1193799
work_keys_str_mv AT huijbregtshenricusjtam patientspecificinstrumentationdoesnotimproveradiographicalignmentorclinicaloutcomesaftertotalkneearthroplastyametaanalysis
AT khanriazjk patientspecificinstrumentationdoesnotimproveradiographicalignmentorclinicaloutcomesaftertotalkneearthroplastyametaanalysis
AT sorensenemma patientspecificinstrumentationdoesnotimproveradiographicalignmentorclinicaloutcomesaftertotalkneearthroplastyametaanalysis
AT fickdanielp patientspecificinstrumentationdoesnotimproveradiographicalignmentorclinicaloutcomesaftertotalkneearthroplastyametaanalysis
AT haebichsamantha patientspecificinstrumentationdoesnotimproveradiographicalignmentorclinicaloutcomesaftertotalkneearthroplastyametaanalysis