Standard manual capsulorhexis / Ultrasound phacoemulsification compared to femtosecond laser-assisted capsulorhexis and lens fragmentation in clear cornea small incision cataract surgery

BACKGROUND: Femtosecond-laser assisted clear cornea cataract surgery may hold promise in safer and more effective procedures. We decided to perform a comparative study to standard manual incision phacoemulsification surgery. METHODS: This is a single-center, single-intervention, and prospective comp...

Descripción completa

Detalles Bibliográficos
Autores principales: Kanellopoulos, Anastasios John, Asimellis, George
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2016
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4967293/
https://www.ncbi.nlm.nih.gov/pubmed/27478858
http://dx.doi.org/10.1186/s40662-016-0050-x
_version_ 1782445494476210176
author Kanellopoulos, Anastasios John
Asimellis, George
author_facet Kanellopoulos, Anastasios John
Asimellis, George
author_sort Kanellopoulos, Anastasios John
collection PubMed
description BACKGROUND: Femtosecond-laser assisted clear cornea cataract surgery may hold promise in safer and more effective procedures. We decided to perform a comparative study to standard manual incision phacoemulsification surgery. METHODS: This is a single-center, single-intervention, and prospective comparative data evaluation of 133 consecutive cases subjected to cataract surgery. Group-A (Phaco), manual capsulorhexis & ultrasound phacoemulsification (n = 66); Group-B femtosecond-laser assisted capsulorhexis and lens fragmentation (n = 67), employing the LenSx laser (Alcon Surgical, Ft. Worth, TX). All cases were evaluated for refraction, visual acuity, keratometry, tomography, pachymetry, endothelial cell counts, intraocular pressure, and type of intraocular lens (IOL) implanted. The groups were matched for age, gender, pre-operative vision metrics, and cataract grade, and were followed up to 1 year. RESULTS: In group-A post-operative uncorrected distance visual acuity (UDVA) was 20/20 or better in 61.5 % and 20/25 or better in 78.5 % of the eyes. The femtosecond laser group-B had improved outcomes (p = 0.075 and p = 0.042, respectively): post-operative UDVA was 20/20 or better in 62.7 % of the eyes and 20/25 or better in 85.1 %. Linear regression scatterplots of achieved versus attempted spherical equivalent had excellent regression coefficients (r(2) = 0.983 in group-A and 0.979 in group-B). There were 75.2 % cases in group-A and 80.6 % in group-B (p = 0.8732) within ±0.50 D of targeted refractive equivalent. Slight trend of under-correction was noted in group-A. Average residual manifest cylinder in the toric subgroup-A was -0.50 D (95 % Limit-of-Agreement (LoA) = -0.78 D), and in toric subgroup-B -0.45 D (LoA = -0.45 D). CONCLUSIONS: Mean spherical equivalent refraction and visual acuity are comparable with laser cataract surgery compared with manual capsulorhexis & ultrasound phacoemulsification. Improved astigmatism correction may be among the benefits of femtosecond laser–assisted cataract surgery. Transient corneal edema may be a first day transient disadvantage in femtosecond laser–assisted cataract surgery.
format Online
Article
Text
id pubmed-4967293
institution National Center for Biotechnology Information
language English
publishDate 2016
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-49672932016-07-31 Standard manual capsulorhexis / Ultrasound phacoemulsification compared to femtosecond laser-assisted capsulorhexis and lens fragmentation in clear cornea small incision cataract surgery Kanellopoulos, Anastasios John Asimellis, George Eye Vis (Lond) Research BACKGROUND: Femtosecond-laser assisted clear cornea cataract surgery may hold promise in safer and more effective procedures. We decided to perform a comparative study to standard manual incision phacoemulsification surgery. METHODS: This is a single-center, single-intervention, and prospective comparative data evaluation of 133 consecutive cases subjected to cataract surgery. Group-A (Phaco), manual capsulorhexis & ultrasound phacoemulsification (n = 66); Group-B femtosecond-laser assisted capsulorhexis and lens fragmentation (n = 67), employing the LenSx laser (Alcon Surgical, Ft. Worth, TX). All cases were evaluated for refraction, visual acuity, keratometry, tomography, pachymetry, endothelial cell counts, intraocular pressure, and type of intraocular lens (IOL) implanted. The groups were matched for age, gender, pre-operative vision metrics, and cataract grade, and were followed up to 1 year. RESULTS: In group-A post-operative uncorrected distance visual acuity (UDVA) was 20/20 or better in 61.5 % and 20/25 or better in 78.5 % of the eyes. The femtosecond laser group-B had improved outcomes (p = 0.075 and p = 0.042, respectively): post-operative UDVA was 20/20 or better in 62.7 % of the eyes and 20/25 or better in 85.1 %. Linear regression scatterplots of achieved versus attempted spherical equivalent had excellent regression coefficients (r(2) = 0.983 in group-A and 0.979 in group-B). There were 75.2 % cases in group-A and 80.6 % in group-B (p = 0.8732) within ±0.50 D of targeted refractive equivalent. Slight trend of under-correction was noted in group-A. Average residual manifest cylinder in the toric subgroup-A was -0.50 D (95 % Limit-of-Agreement (LoA) = -0.78 D), and in toric subgroup-B -0.45 D (LoA = -0.45 D). CONCLUSIONS: Mean spherical equivalent refraction and visual acuity are comparable with laser cataract surgery compared with manual capsulorhexis & ultrasound phacoemulsification. Improved astigmatism correction may be among the benefits of femtosecond laser–assisted cataract surgery. Transient corneal edema may be a first day transient disadvantage in femtosecond laser–assisted cataract surgery. BioMed Central 2016-07-29 /pmc/articles/PMC4967293/ /pubmed/27478858 http://dx.doi.org/10.1186/s40662-016-0050-x Text en © The Author(s). 2016 Open AccessThis article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated.
spellingShingle Research
Kanellopoulos, Anastasios John
Asimellis, George
Standard manual capsulorhexis / Ultrasound phacoemulsification compared to femtosecond laser-assisted capsulorhexis and lens fragmentation in clear cornea small incision cataract surgery
title Standard manual capsulorhexis / Ultrasound phacoemulsification compared to femtosecond laser-assisted capsulorhexis and lens fragmentation in clear cornea small incision cataract surgery
title_full Standard manual capsulorhexis / Ultrasound phacoemulsification compared to femtosecond laser-assisted capsulorhexis and lens fragmentation in clear cornea small incision cataract surgery
title_fullStr Standard manual capsulorhexis / Ultrasound phacoemulsification compared to femtosecond laser-assisted capsulorhexis and lens fragmentation in clear cornea small incision cataract surgery
title_full_unstemmed Standard manual capsulorhexis / Ultrasound phacoemulsification compared to femtosecond laser-assisted capsulorhexis and lens fragmentation in clear cornea small incision cataract surgery
title_short Standard manual capsulorhexis / Ultrasound phacoemulsification compared to femtosecond laser-assisted capsulorhexis and lens fragmentation in clear cornea small incision cataract surgery
title_sort standard manual capsulorhexis / ultrasound phacoemulsification compared to femtosecond laser-assisted capsulorhexis and lens fragmentation in clear cornea small incision cataract surgery
topic Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4967293/
https://www.ncbi.nlm.nih.gov/pubmed/27478858
http://dx.doi.org/10.1186/s40662-016-0050-x
work_keys_str_mv AT kanellopoulosanastasiosjohn standardmanualcapsulorhexisultrasoundphacoemulsificationcomparedtofemtosecondlaserassistedcapsulorhexisandlensfragmentationinclearcorneasmallincisioncataractsurgery
AT asimellisgeorge standardmanualcapsulorhexisultrasoundphacoemulsificationcomparedtofemtosecondlaserassistedcapsulorhexisandlensfragmentationinclearcorneasmallincisioncataractsurgery