Cargando…

From first to latest imaging technology: Revisiting the first mummy investigated with X-ray in 1896 by using dual-source computed tomography

PURPOSE: The aim of this study was to systematically reinvestigate the first human mummy that was ever analyzed with X-ray imaging in 1896, using dual-source computed tomography (DSCT) in order to compare the earliest and latest imaging technologies, to estimate preservation, age at death, sex, anat...

Descripción completa

Detalles Bibliográficos
Autores principales: Zesch, Stephanie, Panzer, Stephanie, Rosendahl, Wilfried, Nance, John W., Schönberg, Stefan O., Henzler, Thomas
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Elsevier 2016
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4968187/
https://www.ncbi.nlm.nih.gov/pubmed/27504475
http://dx.doi.org/10.1016/j.ejro.2016.07.002
_version_ 1782445622841835520
author Zesch, Stephanie
Panzer, Stephanie
Rosendahl, Wilfried
Nance, John W.
Schönberg, Stefan O.
Henzler, Thomas
author_facet Zesch, Stephanie
Panzer, Stephanie
Rosendahl, Wilfried
Nance, John W.
Schönberg, Stefan O.
Henzler, Thomas
author_sort Zesch, Stephanie
collection PubMed
description PURPOSE: The aim of this study was to systematically reinvestigate the first human mummy that was ever analyzed with X-ray imaging in 1896, using dual-source computed tomography (DSCT) in order to compare the earliest and latest imaging technologies, to estimate preservation, age at death, sex, anatomical variants, paleopathological findings, mummification, embalming and wrapping of the child mummy from ancient Egypt. Radiocarbon dating was used to determine the mummy’s age and to specify the child’s living period in the Egyptian chronology. MATERIAL AND METHODS: The ancient Egyptian child mummy is kept in the Senckenberg Museum of Natural History in Frankfurt am Main, Germany. An accelerator mass spectrometer (MICADAS) was used for radiocarbon dating. DSCT was performed using a 2 × 64 slice dual-source CT system (Siemens Healthineers, Forchheim, Germany). A thorough visual examination of the mummy, a systematic radiological evaluation of the DICOM datasets, and established methods in physical anthropology were applied to assess the bio-anthropological data and the post mortem treatment of the body. RESULTS: Radiocarbon dating yielded a calibrated age between 378 and 235 cal BC (95.4% confidence interval), corresponding with the beginning of the Ptolemaic period. The mummy was a male who was four to five years old at the time of death. Remnants of the brain and inner organs were preserved by the embalmers, which is regularly observed in ancient Egyptian child mummies. Skin tissue, inner organs, tendons and/or musculature, cartilage, nerves and vasculature could be identified on the DSCT dataset. The dental health of the child was excellent. Anatomical variants and pathological defects included a congenital Pectus excavatum deformity, hepatomegaly, Harris lines, and longitudinal clefts in the ventral cortices of both femora. CONCLUSION: Our results highlight the enormous progress achieved form earliest to latest imaging technology for advanced mummy research using the first human mummy investigated with X-ray. With the application of DSCT, detailed knowledge regarding age at death, sex, diseases, death, and mummification of a child from Ptolemaic Egypt are revealed while considering the temporary rites of body treatment and burial for children.
format Online
Article
Text
id pubmed-4968187
institution National Center for Biotechnology Information
language English
publishDate 2016
publisher Elsevier
record_format MEDLINE/PubMed
spelling pubmed-49681872016-08-08 From first to latest imaging technology: Revisiting the first mummy investigated with X-ray in 1896 by using dual-source computed tomography Zesch, Stephanie Panzer, Stephanie Rosendahl, Wilfried Nance, John W. Schönberg, Stefan O. Henzler, Thomas Eur J Radiol Open Article PURPOSE: The aim of this study was to systematically reinvestigate the first human mummy that was ever analyzed with X-ray imaging in 1896, using dual-source computed tomography (DSCT) in order to compare the earliest and latest imaging technologies, to estimate preservation, age at death, sex, anatomical variants, paleopathological findings, mummification, embalming and wrapping of the child mummy from ancient Egypt. Radiocarbon dating was used to determine the mummy’s age and to specify the child’s living period in the Egyptian chronology. MATERIAL AND METHODS: The ancient Egyptian child mummy is kept in the Senckenberg Museum of Natural History in Frankfurt am Main, Germany. An accelerator mass spectrometer (MICADAS) was used for radiocarbon dating. DSCT was performed using a 2 × 64 slice dual-source CT system (Siemens Healthineers, Forchheim, Germany). A thorough visual examination of the mummy, a systematic radiological evaluation of the DICOM datasets, and established methods in physical anthropology were applied to assess the bio-anthropological data and the post mortem treatment of the body. RESULTS: Radiocarbon dating yielded a calibrated age between 378 and 235 cal BC (95.4% confidence interval), corresponding with the beginning of the Ptolemaic period. The mummy was a male who was four to five years old at the time of death. Remnants of the brain and inner organs were preserved by the embalmers, which is regularly observed in ancient Egyptian child mummies. Skin tissue, inner organs, tendons and/or musculature, cartilage, nerves and vasculature could be identified on the DSCT dataset. The dental health of the child was excellent. Anatomical variants and pathological defects included a congenital Pectus excavatum deformity, hepatomegaly, Harris lines, and longitudinal clefts in the ventral cortices of both femora. CONCLUSION: Our results highlight the enormous progress achieved form earliest to latest imaging technology for advanced mummy research using the first human mummy investigated with X-ray. With the application of DSCT, detailed knowledge regarding age at death, sex, diseases, death, and mummification of a child from Ptolemaic Egypt are revealed while considering the temporary rites of body treatment and burial for children. Elsevier 2016-07-25 /pmc/articles/PMC4968187/ /pubmed/27504475 http://dx.doi.org/10.1016/j.ejro.2016.07.002 Text en © 2016 The Authors http://creativecommons.org/licenses/by-nc-nd/4.0/ This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).
spellingShingle Article
Zesch, Stephanie
Panzer, Stephanie
Rosendahl, Wilfried
Nance, John W.
Schönberg, Stefan O.
Henzler, Thomas
From first to latest imaging technology: Revisiting the first mummy investigated with X-ray in 1896 by using dual-source computed tomography
title From first to latest imaging technology: Revisiting the first mummy investigated with X-ray in 1896 by using dual-source computed tomography
title_full From first to latest imaging technology: Revisiting the first mummy investigated with X-ray in 1896 by using dual-source computed tomography
title_fullStr From first to latest imaging technology: Revisiting the first mummy investigated with X-ray in 1896 by using dual-source computed tomography
title_full_unstemmed From first to latest imaging technology: Revisiting the first mummy investigated with X-ray in 1896 by using dual-source computed tomography
title_short From first to latest imaging technology: Revisiting the first mummy investigated with X-ray in 1896 by using dual-source computed tomography
title_sort from first to latest imaging technology: revisiting the first mummy investigated with x-ray in 1896 by using dual-source computed tomography
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4968187/
https://www.ncbi.nlm.nih.gov/pubmed/27504475
http://dx.doi.org/10.1016/j.ejro.2016.07.002
work_keys_str_mv AT zeschstephanie fromfirsttolatestimagingtechnologyrevisitingthefirstmummyinvestigatedwithxrayin1896byusingdualsourcecomputedtomography
AT panzerstephanie fromfirsttolatestimagingtechnologyrevisitingthefirstmummyinvestigatedwithxrayin1896byusingdualsourcecomputedtomography
AT rosendahlwilfried fromfirsttolatestimagingtechnologyrevisitingthefirstmummyinvestigatedwithxrayin1896byusingdualsourcecomputedtomography
AT nancejohnw fromfirsttolatestimagingtechnologyrevisitingthefirstmummyinvestigatedwithxrayin1896byusingdualsourcecomputedtomography
AT schonbergstefano fromfirsttolatestimagingtechnologyrevisitingthefirstmummyinvestigatedwithxrayin1896byusingdualsourcecomputedtomography
AT henzlerthomas fromfirsttolatestimagingtechnologyrevisitingthefirstmummyinvestigatedwithxrayin1896byusingdualsourcecomputedtomography