Cargando…

Mass Screening of Youth Athletes for High Risk Landing Patterns using a Portable and Inexpensive Motion Sensor Device

OBJECTIVES: Biomechanical factors such as dynamic knee valgus predispose young athletes to lower extremity injury including tears of the anterior cruciate ligament (ACL). Identifying these risk factors may allow for targeted injury prevention strategies. Our prior work has validated the Microsoft Ki...

Descripción completa

Detalles Bibliográficos
Autores principales: Sherman, Seth Lawrence, Gulbrandsen, Trevor R., Miller, Scott M., Guess, Trent, Willis, Bradley W., Blecha, Kyle M., Huo, Zhiyu, Skubic, Marjorie, Gray, Aaron D.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: SAGE Publications 2016
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4968261/
http://dx.doi.org/10.1177/2325967116S00120
_version_ 1782445628577546240
author Sherman, Seth Lawrence
Gulbrandsen, Trevor R.
Miller, Scott M.
Guess, Trent
Willis, Bradley W.
Blecha, Kyle M.
Huo, Zhiyu
Skubic, Marjorie
Gray, Aaron D.
author_facet Sherman, Seth Lawrence
Gulbrandsen, Trevor R.
Miller, Scott M.
Guess, Trent
Willis, Bradley W.
Blecha, Kyle M.
Huo, Zhiyu
Skubic, Marjorie
Gray, Aaron D.
author_sort Sherman, Seth Lawrence
collection PubMed
description OBJECTIVES: Biomechanical factors such as dynamic knee valgus predispose young athletes to lower extremity injury including tears of the anterior cruciate ligament (ACL). Identifying these risk factors may allow for targeted injury prevention strategies. Our prior work has validated the Microsoft Kinect vs. Vicon to detect knee-ankle separation ratio (KASR) during the drop vertical jump test (DVJ). Our hypothesis is that screening with the Microsoft Kinect will be safe, efficient, and provide information to help detect injury risk in youth athletes. METHODS: A total of 180 healthy high school athletes, ages 14-18 (80 males and 100 females, age of 16.9 ± 1.31 and BMI of 22.8 ± 3.7) participated in this study. Each subject performed three successful DVJ (Fig. 1). We used an inexpensive, portable motion sensor device to measure the KASR, which captures the ratio of the horizontal distance between knees to the horizontal distance between ankles. From previous studies, a KASR value <1 indicates dynamic valgus, while being below 0.6 is considered severe risk. Demographic information and measurements for KASR on initial contact and peak flexion were analyzed statistically. RESULTS: Using two motion sensor device stations, it took 1.5 minutes to screen and test each subject. There were no injuries that occurred during the screening process. Our results showed a statistically significant difference between male and female KASR for both initial contact (p<0.001) and peak flexion (p<0.001). Sixty out of the 100 female subjects (60%) tested positive for valgus (9 initial contact KASR, 1 peak flexion KASR, 50 both initial contact and peak flexion KASR) with two subjects screening for severe risk (KASR<0.6). The average KASR for females was 1.01 (peak flexion) and 0.967 (initial contact). Eighteen out of the 80 male subjects (22.5%) tested positive for valgus (6 initial contact KASR, 2 peak flexion KASR, 10 both initial contact and peak flexion KASR) with no male subjects screening positive for severe risk. The average KASR for males was 1.26 (peak flexion) and 1.13 (initial contact). Comparing males and females that screened positive for KASR, there was a significant gender difference between the KASR at initial contact with females exhibiting more valgus than males (p<0.001) (Table 1). CONCLUSION: Our findings suggest that a portable and inexpensive motion analysis device can detect dynamic valgus during the DVJ in youth athletes. Large scale screening for dynamic valgus was safe and efficient. Known gender disparities between male and females for neuromuscular imbalances were identified. Potential use of this information for targeted injury prevention is appealing and requires further investigation.
format Online
Article
Text
id pubmed-4968261
institution National Center for Biotechnology Information
language English
publishDate 2016
publisher SAGE Publications
record_format MEDLINE/PubMed
spelling pubmed-49682612016-08-11 Mass Screening of Youth Athletes for High Risk Landing Patterns using a Portable and Inexpensive Motion Sensor Device Sherman, Seth Lawrence Gulbrandsen, Trevor R. Miller, Scott M. Guess, Trent Willis, Bradley W. Blecha, Kyle M. Huo, Zhiyu Skubic, Marjorie Gray, Aaron D. Orthop J Sports Med Article OBJECTIVES: Biomechanical factors such as dynamic knee valgus predispose young athletes to lower extremity injury including tears of the anterior cruciate ligament (ACL). Identifying these risk factors may allow for targeted injury prevention strategies. Our prior work has validated the Microsoft Kinect vs. Vicon to detect knee-ankle separation ratio (KASR) during the drop vertical jump test (DVJ). Our hypothesis is that screening with the Microsoft Kinect will be safe, efficient, and provide information to help detect injury risk in youth athletes. METHODS: A total of 180 healthy high school athletes, ages 14-18 (80 males and 100 females, age of 16.9 ± 1.31 and BMI of 22.8 ± 3.7) participated in this study. Each subject performed three successful DVJ (Fig. 1). We used an inexpensive, portable motion sensor device to measure the KASR, which captures the ratio of the horizontal distance between knees to the horizontal distance between ankles. From previous studies, a KASR value <1 indicates dynamic valgus, while being below 0.6 is considered severe risk. Demographic information and measurements for KASR on initial contact and peak flexion were analyzed statistically. RESULTS: Using two motion sensor device stations, it took 1.5 minutes to screen and test each subject. There were no injuries that occurred during the screening process. Our results showed a statistically significant difference between male and female KASR for both initial contact (p<0.001) and peak flexion (p<0.001). Sixty out of the 100 female subjects (60%) tested positive for valgus (9 initial contact KASR, 1 peak flexion KASR, 50 both initial contact and peak flexion KASR) with two subjects screening for severe risk (KASR<0.6). The average KASR for females was 1.01 (peak flexion) and 0.967 (initial contact). Eighteen out of the 80 male subjects (22.5%) tested positive for valgus (6 initial contact KASR, 2 peak flexion KASR, 10 both initial contact and peak flexion KASR) with no male subjects screening positive for severe risk. The average KASR for males was 1.26 (peak flexion) and 1.13 (initial contact). Comparing males and females that screened positive for KASR, there was a significant gender difference between the KASR at initial contact with females exhibiting more valgus than males (p<0.001) (Table 1). CONCLUSION: Our findings suggest that a portable and inexpensive motion analysis device can detect dynamic valgus during the DVJ in youth athletes. Large scale screening for dynamic valgus was safe and efficient. Known gender disparities between male and females for neuromuscular imbalances were identified. Potential use of this information for targeted injury prevention is appealing and requires further investigation. SAGE Publications 2016-07-29 /pmc/articles/PMC4968261/ http://dx.doi.org/10.1177/2325967116S00120 Text en © The Author(s) 2016 http://creativecommons.org/licenses/by-nc-nd/3.0/ This open-access article is published and distributed under the Creative Commons Attribution - NonCommercial - No Derivatives License (http://creativecommons.org/licenses/by-nc-nd/3.0/), which permits the noncommercial use, distribution, and reproduction of the article in any medium, provided the original author and source are credited. You may not alter, transform, or build upon this article without the permission of the Author(s). For reprints and permission queries, please visit SAGE’s Web site at http://www.sagepub.com/journalsPermissions.nav.
spellingShingle Article
Sherman, Seth Lawrence
Gulbrandsen, Trevor R.
Miller, Scott M.
Guess, Trent
Willis, Bradley W.
Blecha, Kyle M.
Huo, Zhiyu
Skubic, Marjorie
Gray, Aaron D.
Mass Screening of Youth Athletes for High Risk Landing Patterns using a Portable and Inexpensive Motion Sensor Device
title Mass Screening of Youth Athletes for High Risk Landing Patterns using a Portable and Inexpensive Motion Sensor Device
title_full Mass Screening of Youth Athletes for High Risk Landing Patterns using a Portable and Inexpensive Motion Sensor Device
title_fullStr Mass Screening of Youth Athletes for High Risk Landing Patterns using a Portable and Inexpensive Motion Sensor Device
title_full_unstemmed Mass Screening of Youth Athletes for High Risk Landing Patterns using a Portable and Inexpensive Motion Sensor Device
title_short Mass Screening of Youth Athletes for High Risk Landing Patterns using a Portable and Inexpensive Motion Sensor Device
title_sort mass screening of youth athletes for high risk landing patterns using a portable and inexpensive motion sensor device
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4968261/
http://dx.doi.org/10.1177/2325967116S00120
work_keys_str_mv AT shermansethlawrence massscreeningofyouthathletesforhighrisklandingpatternsusingaportableandinexpensivemotionsensordevice
AT gulbrandsentrevorr massscreeningofyouthathletesforhighrisklandingpatternsusingaportableandinexpensivemotionsensordevice
AT millerscottm massscreeningofyouthathletesforhighrisklandingpatternsusingaportableandinexpensivemotionsensordevice
AT guesstrent massscreeningofyouthathletesforhighrisklandingpatternsusingaportableandinexpensivemotionsensordevice
AT willisbradleyw massscreeningofyouthathletesforhighrisklandingpatternsusingaportableandinexpensivemotionsensordevice
AT blechakylem massscreeningofyouthathletesforhighrisklandingpatternsusingaportableandinexpensivemotionsensordevice
AT huozhiyu massscreeningofyouthathletesforhighrisklandingpatternsusingaportableandinexpensivemotionsensordevice
AT skubicmarjorie massscreeningofyouthathletesforhighrisklandingpatternsusingaportableandinexpensivemotionsensordevice
AT grayaarond massscreeningofyouthathletesforhighrisklandingpatternsusingaportableandinexpensivemotionsensordevice