Cargando…

Aqueous Flow Measured by Fluorophotometry in the Mouse

PURPOSE: A fluorophotometer designed to measure aqueous flow in murine eyes was tested with artificial fluorescein chambers and in live mice with different anesthesia regimens, aqueous flow suppressants, and an anterior chamber cannulation method. METHODS: Two hours following topical fluorescein app...

Descripción completa

Detalles Bibliográficos
Autores principales: Toris, Carol B., Fan, Shan, Johnson, Thomas V., Camras, Lucinda J., Hays, Cassandra L., Liu, Hong, Ishimoto, Bruce M.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: The Association for Research in Vision and Ophthalmology 2016
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4968429/
https://www.ncbi.nlm.nih.gov/pubmed/27447085
http://dx.doi.org/10.1167/iovs.14-15144
_version_ 1782445657269731328
author Toris, Carol B.
Fan, Shan
Johnson, Thomas V.
Camras, Lucinda J.
Hays, Cassandra L.
Liu, Hong
Ishimoto, Bruce M.
author_facet Toris, Carol B.
Fan, Shan
Johnson, Thomas V.
Camras, Lucinda J.
Hays, Cassandra L.
Liu, Hong
Ishimoto, Bruce M.
author_sort Toris, Carol B.
collection PubMed
description PURPOSE: A fluorophotometer designed to measure aqueous flow in murine eyes was tested with artificial fluorescein chambers and in live mice with different anesthesia regimens, aqueous flow suppressants, and an anterior chamber cannulation method. METHODS: Two hours following topical fluorescein application, one group of CD-1 mice was anesthetized with ketamine/xylazine, 2,2,2-tribromoethanol, or ketamine alone. Cornea and anterior chamber fluorescein concentrations were measured periodically for 60 to 90 minutes by fluorophotometric scans to calculate aqueous flow. Later, a subgroup of mice underwent aqueous flow measurement by anterior chamber cannulation. A third group was treated with timolol, dorzolamide, and vehicle in a crossover manner 1 hour prior to fluorophotometric scans. RESULTS: Aqueous flow with ketamine/xylazine anesthesia (0.09 ± 0.05 μL/min, mean ± SD, n = 24) was slower than with tribromoethanol or ketamine alone (P < 0.001). Timolol reduced aqueous flow from 0.20 ± 0.07 μL/min to 0.07 ± 0.03 μL/min (P = 0.001) under tribromoethanol anesthesia and from 0.14 ± 0.03 μL/min to 0.10 ± 0.02 μL/min (P = 0.004) under ketamine anesthesia but not under ketamine/xylazine anesthesia. Dorzolamide reduced aqueous flow from 0.09 ± 0.03 to 0.06 ± 0.03 μL/min (P = 0.04) under ketamine/xylazine anesthesia. Aqueous flow by anterior chamber cannulation (0.20 ± 0.13 μL/min) was greater (P = 0.05) than by fluorophotometry (0.09 ± 0.07 μL/min). CONCLUSIONS: A new noninvasive fluorophotometric method detected effects of general anesthesia and known aqueous suppressants on aqueous flow in mice. Aqueous flow measured by fluorophotometry was slower than by cannulation, and was technically easier with less variability. The mouse fluorophotometer is useful for repeated measurements of aqueous flow in the murine eye making crossover and longitudinal studies possible.
format Online
Article
Text
id pubmed-4968429
institution National Center for Biotechnology Information
language English
publishDate 2016
publisher The Association for Research in Vision and Ophthalmology
record_format MEDLINE/PubMed
spelling pubmed-49684292017-01-01 Aqueous Flow Measured by Fluorophotometry in the Mouse Toris, Carol B. Fan, Shan Johnson, Thomas V. Camras, Lucinda J. Hays, Cassandra L. Liu, Hong Ishimoto, Bruce M. Invest Ophthalmol Vis Sci Glaucoma PURPOSE: A fluorophotometer designed to measure aqueous flow in murine eyes was tested with artificial fluorescein chambers and in live mice with different anesthesia regimens, aqueous flow suppressants, and an anterior chamber cannulation method. METHODS: Two hours following topical fluorescein application, one group of CD-1 mice was anesthetized with ketamine/xylazine, 2,2,2-tribromoethanol, or ketamine alone. Cornea and anterior chamber fluorescein concentrations were measured periodically for 60 to 90 minutes by fluorophotometric scans to calculate aqueous flow. Later, a subgroup of mice underwent aqueous flow measurement by anterior chamber cannulation. A third group was treated with timolol, dorzolamide, and vehicle in a crossover manner 1 hour prior to fluorophotometric scans. RESULTS: Aqueous flow with ketamine/xylazine anesthesia (0.09 ± 0.05 μL/min, mean ± SD, n = 24) was slower than with tribromoethanol or ketamine alone (P < 0.001). Timolol reduced aqueous flow from 0.20 ± 0.07 μL/min to 0.07 ± 0.03 μL/min (P = 0.001) under tribromoethanol anesthesia and from 0.14 ± 0.03 μL/min to 0.10 ± 0.02 μL/min (P = 0.004) under ketamine anesthesia but not under ketamine/xylazine anesthesia. Dorzolamide reduced aqueous flow from 0.09 ± 0.03 to 0.06 ± 0.03 μL/min (P = 0.04) under ketamine/xylazine anesthesia. Aqueous flow by anterior chamber cannulation (0.20 ± 0.13 μL/min) was greater (P = 0.05) than by fluorophotometry (0.09 ± 0.07 μL/min). CONCLUSIONS: A new noninvasive fluorophotometric method detected effects of general anesthesia and known aqueous suppressants on aqueous flow in mice. Aqueous flow measured by fluorophotometry was slower than by cannulation, and was technically easier with less variability. The mouse fluorophotometer is useful for repeated measurements of aqueous flow in the murine eye making crossover and longitudinal studies possible. The Association for Research in Vision and Ophthalmology 2016-07-22 2016-07 /pmc/articles/PMC4968429/ /pubmed/27447085 http://dx.doi.org/10.1167/iovs.14-15144 Text en http://creativecommons.org/licenses/by-nc-nd/4.0/ This work is licensed under a Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 International License.
spellingShingle Glaucoma
Toris, Carol B.
Fan, Shan
Johnson, Thomas V.
Camras, Lucinda J.
Hays, Cassandra L.
Liu, Hong
Ishimoto, Bruce M.
Aqueous Flow Measured by Fluorophotometry in the Mouse
title Aqueous Flow Measured by Fluorophotometry in the Mouse
title_full Aqueous Flow Measured by Fluorophotometry in the Mouse
title_fullStr Aqueous Flow Measured by Fluorophotometry in the Mouse
title_full_unstemmed Aqueous Flow Measured by Fluorophotometry in the Mouse
title_short Aqueous Flow Measured by Fluorophotometry in the Mouse
title_sort aqueous flow measured by fluorophotometry in the mouse
topic Glaucoma
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4968429/
https://www.ncbi.nlm.nih.gov/pubmed/27447085
http://dx.doi.org/10.1167/iovs.14-15144
work_keys_str_mv AT toriscarolb aqueousflowmeasuredbyfluorophotometryinthemouse
AT fanshan aqueousflowmeasuredbyfluorophotometryinthemouse
AT johnsonthomasv aqueousflowmeasuredbyfluorophotometryinthemouse
AT camraslucindaj aqueousflowmeasuredbyfluorophotometryinthemouse
AT hayscassandral aqueousflowmeasuredbyfluorophotometryinthemouse
AT liuhong aqueousflowmeasuredbyfluorophotometryinthemouse
AT ishimotobrucem aqueousflowmeasuredbyfluorophotometryinthemouse