Cargando…

Validity and reliability of isometric muscle strength measurements of hip abduction and abduction with external hip rotation in a bent-hip position using a handheld dynamometer with a belt

[Purpose] This study aimed to investigate the relatedness, reliability, and validity of isometric muscle strength measurements of hip abduction and abduction with an external hip rotation in a bent-hip position using a handheld dynamometer with a belt. [Subjects and Methods] Twenty healthy young adu...

Descripción completa

Detalles Bibliográficos
Autores principales: Aramaki, Hidefumi, Katoh, Munenori, Hiiragi, Yukinobu, Kawasaki, Tsubasa, Kurihara, Tomohisa, Ohmi, Yorikatsu
Formato: Online Artículo Texto
Lenguaje:English
Publicado: The Society of Physical Therapy Science 2016
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4968521/
https://www.ncbi.nlm.nih.gov/pubmed/27512280
http://dx.doi.org/10.1589/jpts.28.2123
_version_ 1782445677341573120
author Aramaki, Hidefumi
Katoh, Munenori
Hiiragi, Yukinobu
Kawasaki, Tsubasa
Kurihara, Tomohisa
Ohmi, Yorikatsu
author_facet Aramaki, Hidefumi
Katoh, Munenori
Hiiragi, Yukinobu
Kawasaki, Tsubasa
Kurihara, Tomohisa
Ohmi, Yorikatsu
author_sort Aramaki, Hidefumi
collection PubMed
description [Purpose] This study aimed to investigate the relatedness, reliability, and validity of isometric muscle strength measurements of hip abduction and abduction with an external hip rotation in a bent-hip position using a handheld dynamometer with a belt. [Subjects and Methods] Twenty healthy young adults, with a mean age of 21.5 ± 0.6 years were included. Isometric hip muscle strength in the subjects’ right legs was measured under two posture positions using two devices: a handheld dynamometer with a belt and an isokinetic dynamometer. Reliability was evaluated using an intra-class correlation coefficient (ICC); relatedness and validity were evaluated using Pearson’s product moment correlation coefficient. Differences in measurements of devices were assessed by two-way ANOVA. [Results] ICC (1, 1) was ≥0.9; significant positive correlations in measurements were found between the two devices under both conditions. No main effect was found between the measurement values. [Conclusion] Our findings revealed that there was relatedness, reliability, and validity of this method for isometric muscle strength measurements using a handheld dynamometer with a belt.
format Online
Article
Text
id pubmed-4968521
institution National Center for Biotechnology Information
language English
publishDate 2016
publisher The Society of Physical Therapy Science
record_format MEDLINE/PubMed
spelling pubmed-49685212016-08-10 Validity and reliability of isometric muscle strength measurements of hip abduction and abduction with external hip rotation in a bent-hip position using a handheld dynamometer with a belt Aramaki, Hidefumi Katoh, Munenori Hiiragi, Yukinobu Kawasaki, Tsubasa Kurihara, Tomohisa Ohmi, Yorikatsu J Phys Ther Sci Original Article [Purpose] This study aimed to investigate the relatedness, reliability, and validity of isometric muscle strength measurements of hip abduction and abduction with an external hip rotation in a bent-hip position using a handheld dynamometer with a belt. [Subjects and Methods] Twenty healthy young adults, with a mean age of 21.5 ± 0.6 years were included. Isometric hip muscle strength in the subjects’ right legs was measured under two posture positions using two devices: a handheld dynamometer with a belt and an isokinetic dynamometer. Reliability was evaluated using an intra-class correlation coefficient (ICC); relatedness and validity were evaluated using Pearson’s product moment correlation coefficient. Differences in measurements of devices were assessed by two-way ANOVA. [Results] ICC (1, 1) was ≥0.9; significant positive correlations in measurements were found between the two devices under both conditions. No main effect was found between the measurement values. [Conclusion] Our findings revealed that there was relatedness, reliability, and validity of this method for isometric muscle strength measurements using a handheld dynamometer with a belt. The Society of Physical Therapy Science 2016-07-29 2016-07 /pmc/articles/PMC4968521/ /pubmed/27512280 http://dx.doi.org/10.1589/jpts.28.2123 Text en 2016©by the Society of Physical Therapy Science. Published by IPEC Inc. http://creativecommons.org/licenses/by-nc-nd/4.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution Non-Commercial No Derivatives (by-nc-nd) License.
spellingShingle Original Article
Aramaki, Hidefumi
Katoh, Munenori
Hiiragi, Yukinobu
Kawasaki, Tsubasa
Kurihara, Tomohisa
Ohmi, Yorikatsu
Validity and reliability of isometric muscle strength measurements of hip abduction and abduction with external hip rotation in a bent-hip position using a handheld dynamometer with a belt
title Validity and reliability of isometric muscle strength measurements of hip abduction and abduction with external hip rotation in a bent-hip position using a handheld dynamometer with a belt
title_full Validity and reliability of isometric muscle strength measurements of hip abduction and abduction with external hip rotation in a bent-hip position using a handheld dynamometer with a belt
title_fullStr Validity and reliability of isometric muscle strength measurements of hip abduction and abduction with external hip rotation in a bent-hip position using a handheld dynamometer with a belt
title_full_unstemmed Validity and reliability of isometric muscle strength measurements of hip abduction and abduction with external hip rotation in a bent-hip position using a handheld dynamometer with a belt
title_short Validity and reliability of isometric muscle strength measurements of hip abduction and abduction with external hip rotation in a bent-hip position using a handheld dynamometer with a belt
title_sort validity and reliability of isometric muscle strength measurements of hip abduction and abduction with external hip rotation in a bent-hip position using a handheld dynamometer with a belt
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4968521/
https://www.ncbi.nlm.nih.gov/pubmed/27512280
http://dx.doi.org/10.1589/jpts.28.2123
work_keys_str_mv AT aramakihidefumi validityandreliabilityofisometricmusclestrengthmeasurementsofhipabductionandabductionwithexternalhiprotationinabenthippositionusingahandhelddynamometerwithabelt
AT katohmunenori validityandreliabilityofisometricmusclestrengthmeasurementsofhipabductionandabductionwithexternalhiprotationinabenthippositionusingahandhelddynamometerwithabelt
AT hiiragiyukinobu validityandreliabilityofisometricmusclestrengthmeasurementsofhipabductionandabductionwithexternalhiprotationinabenthippositionusingahandhelddynamometerwithabelt
AT kawasakitsubasa validityandreliabilityofisometricmusclestrengthmeasurementsofhipabductionandabductionwithexternalhiprotationinabenthippositionusingahandhelddynamometerwithabelt
AT kuriharatomohisa validityandreliabilityofisometricmusclestrengthmeasurementsofhipabductionandabductionwithexternalhiprotationinabenthippositionusingahandhelddynamometerwithabelt
AT ohmiyorikatsu validityandreliabilityofisometricmusclestrengthmeasurementsofhipabductionandabductionwithexternalhiprotationinabenthippositionusingahandhelddynamometerwithabelt