The effect of X‐ray beam distortion on the Edwards Sapien XT (™) trans‐catheter aortic valve replacement prosthesis
INTRODUCTION: Profiling the Aortic root perpendicular to the fluoroscopic image plane will achieve a more successful implant position for trans‐catheter aortic valve replacement (TAVR). This study aimed to investigate whether the divergent nature of the X‐ray beam from the C‐arm altered the appearan...
Autores principales: | , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
John Wiley and Sons Inc.
2015
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4968560/ https://www.ncbi.nlm.nih.gov/pubmed/27512569 http://dx.doi.org/10.1002/jmrs.131 |
_version_ | 1782445681698406400 |
---|---|
author | Crowhurst, James A. Poon, Karl K. Murdoch, Dale Incani, Alexander Raffel, Owen C. Liddicoat, Annelise Walters, Darren |
author_facet | Crowhurst, James A. Poon, Karl K. Murdoch, Dale Incani, Alexander Raffel, Owen C. Liddicoat, Annelise Walters, Darren |
author_sort | Crowhurst, James A. |
collection | PubMed |
description | INTRODUCTION: Profiling the Aortic root perpendicular to the fluoroscopic image plane will achieve a more successful implant position for trans‐catheter aortic valve replacement (TAVR). This study aimed to investigate whether the divergent nature of the X‐ray beam from the C‐arm altered the appearance of the TAVR device. METHODS: Under bench‐top testing, a 23, 26 and 29 mm Edwards Sapien XT valve was positioned coaxially at the bottom of a fluoroscopic image utilising 22 and 32 cm fields of view (FOV). The table was then moved so that the valve was positioned at the top of the image. The valve's appearance was scored using a previously published three tier classification tool (excellent, satisfactory and poor) and quantified with measurements. The number of degrees of C‐arm rotation that were required to bring the valve back to a coaxial appearance was recorded. RESULTS: When using the 32 cm FOV, the valve's appearance changes from excellent to satisfactory. When a 22 cm FOV was used, the change is less marked. More C‐arm rotation is required to bring the appearance back to coaxial with the 32 cm FOV. CONCLUSION: Not maintaining the valve in the centre of the image can distort the valves appearance. This has the potential to affect the final implantation depth. |
format | Online Article Text |
id | pubmed-4968560 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2015 |
publisher | John Wiley and Sons Inc. |
record_format | MEDLINE/PubMed |
spelling | pubmed-49685602016-08-10 The effect of X‐ray beam distortion on the Edwards Sapien XT (™) trans‐catheter aortic valve replacement prosthesis Crowhurst, James A. Poon, Karl K. Murdoch, Dale Incani, Alexander Raffel, Owen C. Liddicoat, Annelise Walters, Darren J Med Radiat Sci Original Articles INTRODUCTION: Profiling the Aortic root perpendicular to the fluoroscopic image plane will achieve a more successful implant position for trans‐catheter aortic valve replacement (TAVR). This study aimed to investigate whether the divergent nature of the X‐ray beam from the C‐arm altered the appearance of the TAVR device. METHODS: Under bench‐top testing, a 23, 26 and 29 mm Edwards Sapien XT valve was positioned coaxially at the bottom of a fluoroscopic image utilising 22 and 32 cm fields of view (FOV). The table was then moved so that the valve was positioned at the top of the image. The valve's appearance was scored using a previously published three tier classification tool (excellent, satisfactory and poor) and quantified with measurements. The number of degrees of C‐arm rotation that were required to bring the valve back to a coaxial appearance was recorded. RESULTS: When using the 32 cm FOV, the valve's appearance changes from excellent to satisfactory. When a 22 cm FOV was used, the change is less marked. More C‐arm rotation is required to bring the appearance back to coaxial with the 32 cm FOV. CONCLUSION: Not maintaining the valve in the centre of the image can distort the valves appearance. This has the potential to affect the final implantation depth. John Wiley and Sons Inc. 2015-08-30 2015-12 /pmc/articles/PMC4968560/ /pubmed/27512569 http://dx.doi.org/10.1002/jmrs.131 Text en © 2015 The Prince Charles Hospital. Journal of Medical Radiation Sciences published by Wiley Publishing Asia Pty Ltd on behalf of Australian Institute of Radiography and New Zealand Institute of Medical Radiation Technology. This is an open access article under the terms of the Creative Commons Attribution‐NonCommercial‐NoDerivs (http://creativecommons.org/licenses/by-nc-nd/4.0/) License, which permits use and distribution in any medium, provided the original work is properly cited, the use is non‐commercial and no modifications or adaptations are made. |
spellingShingle | Original Articles Crowhurst, James A. Poon, Karl K. Murdoch, Dale Incani, Alexander Raffel, Owen C. Liddicoat, Annelise Walters, Darren The effect of X‐ray beam distortion on the Edwards Sapien XT (™) trans‐catheter aortic valve replacement prosthesis |
title | The effect of X‐ray beam distortion on the Edwards Sapien XT
(™) trans‐catheter aortic valve replacement prosthesis |
title_full | The effect of X‐ray beam distortion on the Edwards Sapien XT
(™) trans‐catheter aortic valve replacement prosthesis |
title_fullStr | The effect of X‐ray beam distortion on the Edwards Sapien XT
(™) trans‐catheter aortic valve replacement prosthesis |
title_full_unstemmed | The effect of X‐ray beam distortion on the Edwards Sapien XT
(™) trans‐catheter aortic valve replacement prosthesis |
title_short | The effect of X‐ray beam distortion on the Edwards Sapien XT
(™) trans‐catheter aortic valve replacement prosthesis |
title_sort | effect of x‐ray beam distortion on the edwards sapien xt
(™) trans‐catheter aortic valve replacement prosthesis |
topic | Original Articles |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4968560/ https://www.ncbi.nlm.nih.gov/pubmed/27512569 http://dx.doi.org/10.1002/jmrs.131 |
work_keys_str_mv | AT crowhurstjamesa theeffectofxraybeamdistortionontheedwardssapienxttranscatheteraorticvalvereplacementprosthesis AT poonkarlk theeffectofxraybeamdistortionontheedwardssapienxttranscatheteraorticvalvereplacementprosthesis AT murdochdale theeffectofxraybeamdistortionontheedwardssapienxttranscatheteraorticvalvereplacementprosthesis AT incanialexander theeffectofxraybeamdistortionontheedwardssapienxttranscatheteraorticvalvereplacementprosthesis AT raffelowenc theeffectofxraybeamdistortionontheedwardssapienxttranscatheteraorticvalvereplacementprosthesis AT liddicoatannelise theeffectofxraybeamdistortionontheedwardssapienxttranscatheteraorticvalvereplacementprosthesis AT waltersdarren theeffectofxraybeamdistortionontheedwardssapienxttranscatheteraorticvalvereplacementprosthesis AT crowhurstjamesa effectofxraybeamdistortionontheedwardssapienxttranscatheteraorticvalvereplacementprosthesis AT poonkarlk effectofxraybeamdistortionontheedwardssapienxttranscatheteraorticvalvereplacementprosthesis AT murdochdale effectofxraybeamdistortionontheedwardssapienxttranscatheteraorticvalvereplacementprosthesis AT incanialexander effectofxraybeamdistortionontheedwardssapienxttranscatheteraorticvalvereplacementprosthesis AT raffelowenc effectofxraybeamdistortionontheedwardssapienxttranscatheteraorticvalvereplacementprosthesis AT liddicoatannelise effectofxraybeamdistortionontheedwardssapienxttranscatheteraorticvalvereplacementprosthesis AT waltersdarren effectofxraybeamdistortionontheedwardssapienxttranscatheteraorticvalvereplacementprosthesis |