Cargando…

Dosimetric impact of different bladder and rectum filling during prostate cancer radiotherapy

BACKGROUND: The aim of this study was to analyze the influence of volumetric changes of bladder and rectum filling on the 3D dose distribution in prostate cancer radiotherapy. METHODS: A total of 314 cone-beam CT (CBCT) image data sets from 19 patients were enrolled in this study. For each CBCT, the...

Descripción completa

Detalles Bibliográficos
Autores principales: Chen, Zhi, Yang, Zhaozhi, Wang, Jiazhou, Hu, Weigang
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2016
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4969718/
https://www.ncbi.nlm.nih.gov/pubmed/27485637
http://dx.doi.org/10.1186/s13014-016-0681-z
_version_ 1782445830534332416
author Chen, Zhi
Yang, Zhaozhi
Wang, Jiazhou
Hu, Weigang
author_facet Chen, Zhi
Yang, Zhaozhi
Wang, Jiazhou
Hu, Weigang
author_sort Chen, Zhi
collection PubMed
description BACKGROUND: The aim of this study was to analyze the influence of volumetric changes of bladder and rectum filling on the 3D dose distribution in prostate cancer radiotherapy. METHODS: A total of 314 cone-beam CT (CBCT) image data sets from 19 patients were enrolled in this study. For each CBCT, the bladder and rectum were contoured and volume sizes were normalized to those on their original CT. The daily delivered dose was recalculated on the CBCT images and the doses to bladder and rectum were investigated. Linear regression analysis was performed to identify the mean dose change of the volume change using SPSS 19. RESULTS: The data show that the variances of the normalized volume of the bladder and the rectum are 0.13–0.58 and 0.12–0.50 respectively. The variances of V(70Gy,) V(60Gy,) V(50Gy,) V(40Gy) and V(30Gy) of bladder are bigger than those of rectum for 17 patients. The linear regression analysis indicates a 10 % increase in bladder volume will cause a 5.6 % (±4.9 %) reduction in mean dose (p <0.05). CONCLUSIONS: The bladder’s volume change is more significant than that of the rectum for the prostate cancer patient. The rectum volume variations are not significant except for air bubbles, which change the shape and the position of the rectum. The bladder volume variations may cause dose changes proportionately. Monitoring the bladder’s volume before fractional treatment delivery will be crucial for accurate dose delivery.
format Online
Article
Text
id pubmed-4969718
institution National Center for Biotechnology Information
language English
publishDate 2016
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-49697182016-08-03 Dosimetric impact of different bladder and rectum filling during prostate cancer radiotherapy Chen, Zhi Yang, Zhaozhi Wang, Jiazhou Hu, Weigang Radiat Oncol Research BACKGROUND: The aim of this study was to analyze the influence of volumetric changes of bladder and rectum filling on the 3D dose distribution in prostate cancer radiotherapy. METHODS: A total of 314 cone-beam CT (CBCT) image data sets from 19 patients were enrolled in this study. For each CBCT, the bladder and rectum were contoured and volume sizes were normalized to those on their original CT. The daily delivered dose was recalculated on the CBCT images and the doses to bladder and rectum were investigated. Linear regression analysis was performed to identify the mean dose change of the volume change using SPSS 19. RESULTS: The data show that the variances of the normalized volume of the bladder and the rectum are 0.13–0.58 and 0.12–0.50 respectively. The variances of V(70Gy,) V(60Gy,) V(50Gy,) V(40Gy) and V(30Gy) of bladder are bigger than those of rectum for 17 patients. The linear regression analysis indicates a 10 % increase in bladder volume will cause a 5.6 % (±4.9 %) reduction in mean dose (p <0.05). CONCLUSIONS: The bladder’s volume change is more significant than that of the rectum for the prostate cancer patient. The rectum volume variations are not significant except for air bubbles, which change the shape and the position of the rectum. The bladder volume variations may cause dose changes proportionately. Monitoring the bladder’s volume before fractional treatment delivery will be crucial for accurate dose delivery. BioMed Central 2016-08-02 /pmc/articles/PMC4969718/ /pubmed/27485637 http://dx.doi.org/10.1186/s13014-016-0681-z Text en © The Author(s). 2016 Open AccessThis article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated.
spellingShingle Research
Chen, Zhi
Yang, Zhaozhi
Wang, Jiazhou
Hu, Weigang
Dosimetric impact of different bladder and rectum filling during prostate cancer radiotherapy
title Dosimetric impact of different bladder and rectum filling during prostate cancer radiotherapy
title_full Dosimetric impact of different bladder and rectum filling during prostate cancer radiotherapy
title_fullStr Dosimetric impact of different bladder and rectum filling during prostate cancer radiotherapy
title_full_unstemmed Dosimetric impact of different bladder and rectum filling during prostate cancer radiotherapy
title_short Dosimetric impact of different bladder and rectum filling during prostate cancer radiotherapy
title_sort dosimetric impact of different bladder and rectum filling during prostate cancer radiotherapy
topic Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4969718/
https://www.ncbi.nlm.nih.gov/pubmed/27485637
http://dx.doi.org/10.1186/s13014-016-0681-z
work_keys_str_mv AT chenzhi dosimetricimpactofdifferentbladderandrectumfillingduringprostatecancerradiotherapy
AT yangzhaozhi dosimetricimpactofdifferentbladderandrectumfillingduringprostatecancerradiotherapy
AT wangjiazhou dosimetricimpactofdifferentbladderandrectumfillingduringprostatecancerradiotherapy
AT huweigang dosimetricimpactofdifferentbladderandrectumfillingduringprostatecancerradiotherapy