Cargando…
Microsoft Kinect Visual and Depth Sensors for Breathing and Heart Rate Analysis
This paper is devoted to a new method of using Microsoft (MS) Kinect sensors for non-contact monitoring of breathing and heart rate estimation to detect possible medical and neurological disorders. Video sequences of facial features and thorax movements are recorded by MS Kinect image, depth and inf...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2016
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4970046/ https://www.ncbi.nlm.nih.gov/pubmed/27367687 http://dx.doi.org/10.3390/s16070996 |
_version_ | 1782445899799068672 |
---|---|
author | Procházka, Aleš Schätz, Martin Vyšata, Oldřich Vališ, Martin |
author_facet | Procházka, Aleš Schätz, Martin Vyšata, Oldřich Vališ, Martin |
author_sort | Procházka, Aleš |
collection | PubMed |
description | This paper is devoted to a new method of using Microsoft (MS) Kinect sensors for non-contact monitoring of breathing and heart rate estimation to detect possible medical and neurological disorders. Video sequences of facial features and thorax movements are recorded by MS Kinect image, depth and infrared sensors to enable their time analysis in selected regions of interest. The proposed methodology includes the use of computational methods and functional transforms for data selection, as well as their denoising, spectral analysis and visualization, in order to determine specific biomedical features. The results that were obtained verify the correspondence between the evaluation of the breathing frequency that was obtained from the image and infrared data of the mouth area and from the thorax movement that was recorded by the depth sensor. Spectral analysis of the time evolution of the mouth area video frames was also used for heart rate estimation. Results estimated from the image and infrared data of the mouth area were compared with those obtained by contact measurements by Garmin sensors (www.garmin.com). The study proves that simple image and depth sensors can be used to efficiently record biomedical multidimensional data with sufficient accuracy to detect selected biomedical features using specific methods of computational intelligence. The achieved accuracy for non-contact detection of breathing rate was 0.26% and the accuracy of heart rate estimation was 1.47% for the infrared sensor. The following results show how video frames with depth data can be used to differentiate different kinds of breathing. The proposed method enables us to obtain and analyse data for diagnostic purposes in the home environment or during physical activities, enabling efficient human–machine interaction. |
format | Online Article Text |
id | pubmed-4970046 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2016 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-49700462016-08-04 Microsoft Kinect Visual and Depth Sensors for Breathing and Heart Rate Analysis Procházka, Aleš Schätz, Martin Vyšata, Oldřich Vališ, Martin Sensors (Basel) Article This paper is devoted to a new method of using Microsoft (MS) Kinect sensors for non-contact monitoring of breathing and heart rate estimation to detect possible medical and neurological disorders. Video sequences of facial features and thorax movements are recorded by MS Kinect image, depth and infrared sensors to enable their time analysis in selected regions of interest. The proposed methodology includes the use of computational methods and functional transforms for data selection, as well as their denoising, spectral analysis and visualization, in order to determine specific biomedical features. The results that were obtained verify the correspondence between the evaluation of the breathing frequency that was obtained from the image and infrared data of the mouth area and from the thorax movement that was recorded by the depth sensor. Spectral analysis of the time evolution of the mouth area video frames was also used for heart rate estimation. Results estimated from the image and infrared data of the mouth area were compared with those obtained by contact measurements by Garmin sensors (www.garmin.com). The study proves that simple image and depth sensors can be used to efficiently record biomedical multidimensional data with sufficient accuracy to detect selected biomedical features using specific methods of computational intelligence. The achieved accuracy for non-contact detection of breathing rate was 0.26% and the accuracy of heart rate estimation was 1.47% for the infrared sensor. The following results show how video frames with depth data can be used to differentiate different kinds of breathing. The proposed method enables us to obtain and analyse data for diagnostic purposes in the home environment or during physical activities, enabling efficient human–machine interaction. MDPI 2016-06-28 /pmc/articles/PMC4970046/ /pubmed/27367687 http://dx.doi.org/10.3390/s16070996 Text en © 2016 by the authors; licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC-BY) license (http://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article Procházka, Aleš Schätz, Martin Vyšata, Oldřich Vališ, Martin Microsoft Kinect Visual and Depth Sensors for Breathing and Heart Rate Analysis |
title | Microsoft Kinect Visual and Depth Sensors for Breathing and Heart Rate Analysis |
title_full | Microsoft Kinect Visual and Depth Sensors for Breathing and Heart Rate Analysis |
title_fullStr | Microsoft Kinect Visual and Depth Sensors for Breathing and Heart Rate Analysis |
title_full_unstemmed | Microsoft Kinect Visual and Depth Sensors for Breathing and Heart Rate Analysis |
title_short | Microsoft Kinect Visual and Depth Sensors for Breathing and Heart Rate Analysis |
title_sort | microsoft kinect visual and depth sensors for breathing and heart rate analysis |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4970046/ https://www.ncbi.nlm.nih.gov/pubmed/27367687 http://dx.doi.org/10.3390/s16070996 |
work_keys_str_mv | AT prochazkaales microsoftkinectvisualanddepthsensorsforbreathingandheartrateanalysis AT schatzmartin microsoftkinectvisualanddepthsensorsforbreathingandheartrateanalysis AT vysataoldrich microsoftkinectvisualanddepthsensorsforbreathingandheartrateanalysis AT valismartin microsoftkinectvisualanddepthsensorsforbreathingandheartrateanalysis |