Cargando…

An Enhanced Technique for Ultrasonic Flow Metering Featuring Very Low Jitter and Offset

This paper proposes a new, improved method for water flow metering. It applies to a transit time ultrasonic flow meter device. In principle, the flow of a given liquid in a pipe is obtained by measuring the transit times of an ultrasonic wave in the upstream and downstream directions. The difference...

Descripción completa

Detalles Bibliográficos
Autores principales: Hamouda, Assia, Manck, Otto, Hafiane, Mohamed Lamine, Bouguechal, Nour-Eddine
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2016
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4970058/
https://www.ncbi.nlm.nih.gov/pubmed/27367701
http://dx.doi.org/10.3390/s16071008
_version_ 1782445902484471808
author Hamouda, Assia
Manck, Otto
Hafiane, Mohamed Lamine
Bouguechal, Nour-Eddine
author_facet Hamouda, Assia
Manck, Otto
Hafiane, Mohamed Lamine
Bouguechal, Nour-Eddine
author_sort Hamouda, Assia
collection PubMed
description This paper proposes a new, improved method for water flow metering. It applies to a transit time ultrasonic flow meter device. In principle, the flow of a given liquid in a pipe is obtained by measuring the transit times of an ultrasonic wave in the upstream and downstream directions. The difference between these times is, in theory, linearly proportional to the liquid flow velocity. However, the fainter the flow is, the smaller the transit time difference (TTD) is. This difference can be as low as a few picoseconds, which gives rise to many technical difficulties in measuring such a small time difference with a given accuracy. The proposed method relies on measuring the TTD indirectly by computing the phase difference between the steady-state parts of the received signals in the upstream and downstream directions and by using a least-square-sine-fitting technique. This reduces the effect of the jitter noise and the offset, which limit measurement precision at very low flow velocity. The obtained measurement results illustrate the robustness of the proposed method, as we measure the TTD at no-flow conditions, with a precision as low as 10 ps peak-to-peak and a TTD offset of zero, within a temperature range from room temperature to 80 °C. This allows us to reach a smaller minimum detectable flow when compared with previous techniques. The proposed method exhibits a better trade-off between measurement accuracy and system complexity. It can be completely integrated in an ASIC (application specific integrated circuit) or incorporated in a CPU- or micro-controller-based system.
format Online
Article
Text
id pubmed-4970058
institution National Center for Biotechnology Information
language English
publishDate 2016
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-49700582016-08-04 An Enhanced Technique for Ultrasonic Flow Metering Featuring Very Low Jitter and Offset Hamouda, Assia Manck, Otto Hafiane, Mohamed Lamine Bouguechal, Nour-Eddine Sensors (Basel) Article This paper proposes a new, improved method for water flow metering. It applies to a transit time ultrasonic flow meter device. In principle, the flow of a given liquid in a pipe is obtained by measuring the transit times of an ultrasonic wave in the upstream and downstream directions. The difference between these times is, in theory, linearly proportional to the liquid flow velocity. However, the fainter the flow is, the smaller the transit time difference (TTD) is. This difference can be as low as a few picoseconds, which gives rise to many technical difficulties in measuring such a small time difference with a given accuracy. The proposed method relies on measuring the TTD indirectly by computing the phase difference between the steady-state parts of the received signals in the upstream and downstream directions and by using a least-square-sine-fitting technique. This reduces the effect of the jitter noise and the offset, which limit measurement precision at very low flow velocity. The obtained measurement results illustrate the robustness of the proposed method, as we measure the TTD at no-flow conditions, with a precision as low as 10 ps peak-to-peak and a TTD offset of zero, within a temperature range from room temperature to 80 °C. This allows us to reach a smaller minimum detectable flow when compared with previous techniques. The proposed method exhibits a better trade-off between measurement accuracy and system complexity. It can be completely integrated in an ASIC (application specific integrated circuit) or incorporated in a CPU- or micro-controller-based system. MDPI 2016-06-29 /pmc/articles/PMC4970058/ /pubmed/27367701 http://dx.doi.org/10.3390/s16071008 Text en © 2016 by the authors; licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC-BY) license (http://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Hamouda, Assia
Manck, Otto
Hafiane, Mohamed Lamine
Bouguechal, Nour-Eddine
An Enhanced Technique for Ultrasonic Flow Metering Featuring Very Low Jitter and Offset
title An Enhanced Technique for Ultrasonic Flow Metering Featuring Very Low Jitter and Offset
title_full An Enhanced Technique for Ultrasonic Flow Metering Featuring Very Low Jitter and Offset
title_fullStr An Enhanced Technique for Ultrasonic Flow Metering Featuring Very Low Jitter and Offset
title_full_unstemmed An Enhanced Technique for Ultrasonic Flow Metering Featuring Very Low Jitter and Offset
title_short An Enhanced Technique for Ultrasonic Flow Metering Featuring Very Low Jitter and Offset
title_sort enhanced technique for ultrasonic flow metering featuring very low jitter and offset
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4970058/
https://www.ncbi.nlm.nih.gov/pubmed/27367701
http://dx.doi.org/10.3390/s16071008
work_keys_str_mv AT hamoudaassia anenhancedtechniqueforultrasonicflowmeteringfeaturingverylowjitterandoffset
AT manckotto anenhancedtechniqueforultrasonicflowmeteringfeaturingverylowjitterandoffset
AT hafianemohamedlamine anenhancedtechniqueforultrasonicflowmeteringfeaturingverylowjitterandoffset
AT bouguechalnoureddine anenhancedtechniqueforultrasonicflowmeteringfeaturingverylowjitterandoffset
AT hamoudaassia enhancedtechniqueforultrasonicflowmeteringfeaturingverylowjitterandoffset
AT manckotto enhancedtechniqueforultrasonicflowmeteringfeaturingverylowjitterandoffset
AT hafianemohamedlamine enhancedtechniqueforultrasonicflowmeteringfeaturingverylowjitterandoffset
AT bouguechalnoureddine enhancedtechniqueforultrasonicflowmeteringfeaturingverylowjitterandoffset