Cargando…

Exchange Bias Tuning for Magnetoresistive Sensors by Inclusion of Non-Magnetic Impurities

The fine control of the exchange coupling strength and blocking temperature ofexchange bias systems is an important requirement for the development of magnetoresistive sensors with two pinned electrodes. In this paper, we successfully tune these parameters in top- and bottom-pinned systems, comprisi...

Descripción completa

Detalles Bibliográficos
Autores principales: Sharma, Parikshit Pratim, Albisetti, Edoardo, Monticelli, Marco, Bertacco, Riccardo, Petti, Daniela
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2016
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4970079/
https://www.ncbi.nlm.nih.gov/pubmed/27384565
http://dx.doi.org/10.3390/s16071030
_version_ 1782445907176849408
author Sharma, Parikshit Pratim
Albisetti, Edoardo
Monticelli, Marco
Bertacco, Riccardo
Petti, Daniela
author_facet Sharma, Parikshit Pratim
Albisetti, Edoardo
Monticelli, Marco
Bertacco, Riccardo
Petti, Daniela
author_sort Sharma, Parikshit Pratim
collection PubMed
description The fine control of the exchange coupling strength and blocking temperature ofexchange bias systems is an important requirement for the development of magnetoresistive sensors with two pinned electrodes. In this paper, we successfully tune these parameters in top- and bottom-pinned systems, comprising 5 nm thick Co(40)Fe(40)B(20) and 6.5 nm thick Ir(22)Mn(78) films. By inserting Ru impurities at different concentrations in the Ir(22)Mn(78) layer, blocking temperatures ranging from 220 °C to 100 °C and exchange bias fields from 200 Oe to 60 Oe are obtained. This method is then applied to the fabrication of sensors based on magnetic tunneling junctions consisting of a pinned synthetic antiferromagnet reference layer and a top-pinned sensing layer. This work paves the way towards the development of new sensors with finely tuned magnetic anisotropies.
format Online
Article
Text
id pubmed-4970079
institution National Center for Biotechnology Information
language English
publishDate 2016
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-49700792016-08-04 Exchange Bias Tuning for Magnetoresistive Sensors by Inclusion of Non-Magnetic Impurities Sharma, Parikshit Pratim Albisetti, Edoardo Monticelli, Marco Bertacco, Riccardo Petti, Daniela Sensors (Basel) Article The fine control of the exchange coupling strength and blocking temperature ofexchange bias systems is an important requirement for the development of magnetoresistive sensors with two pinned electrodes. In this paper, we successfully tune these parameters in top- and bottom-pinned systems, comprising 5 nm thick Co(40)Fe(40)B(20) and 6.5 nm thick Ir(22)Mn(78) films. By inserting Ru impurities at different concentrations in the Ir(22)Mn(78) layer, blocking temperatures ranging from 220 °C to 100 °C and exchange bias fields from 200 Oe to 60 Oe are obtained. This method is then applied to the fabrication of sensors based on magnetic tunneling junctions consisting of a pinned synthetic antiferromagnet reference layer and a top-pinned sensing layer. This work paves the way towards the development of new sensors with finely tuned magnetic anisotropies. MDPI 2016-07-04 /pmc/articles/PMC4970079/ /pubmed/27384565 http://dx.doi.org/10.3390/s16071030 Text en © 2016 by the authors; licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC-BY) license (http://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Sharma, Parikshit Pratim
Albisetti, Edoardo
Monticelli, Marco
Bertacco, Riccardo
Petti, Daniela
Exchange Bias Tuning for Magnetoresistive Sensors by Inclusion of Non-Magnetic Impurities
title Exchange Bias Tuning for Magnetoresistive Sensors by Inclusion of Non-Magnetic Impurities
title_full Exchange Bias Tuning for Magnetoresistive Sensors by Inclusion of Non-Magnetic Impurities
title_fullStr Exchange Bias Tuning for Magnetoresistive Sensors by Inclusion of Non-Magnetic Impurities
title_full_unstemmed Exchange Bias Tuning for Magnetoresistive Sensors by Inclusion of Non-Magnetic Impurities
title_short Exchange Bias Tuning for Magnetoresistive Sensors by Inclusion of Non-Magnetic Impurities
title_sort exchange bias tuning for magnetoresistive sensors by inclusion of non-magnetic impurities
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4970079/
https://www.ncbi.nlm.nih.gov/pubmed/27384565
http://dx.doi.org/10.3390/s16071030
work_keys_str_mv AT sharmaparikshitpratim exchangebiastuningformagnetoresistivesensorsbyinclusionofnonmagneticimpurities
AT albisettiedoardo exchangebiastuningformagnetoresistivesensorsbyinclusionofnonmagneticimpurities
AT monticellimarco exchangebiastuningformagnetoresistivesensorsbyinclusionofnonmagneticimpurities
AT bertaccoriccardo exchangebiastuningformagnetoresistivesensorsbyinclusionofnonmagneticimpurities
AT pettidaniela exchangebiastuningformagnetoresistivesensorsbyinclusionofnonmagneticimpurities