Cargando…
The Comparison of Compression Hip Screw and Bipolar Hemiarthroplasty for the Treatment of AO Type A2 Intertrochanteric Fractures
PURPOSE: The purpose of this study was to compare the outcomes of osteosynthesis using compression hip screw fixation versus bipolar hemiarthroplasty in AO type A2 intertrochanteric fractures. MATERIALS AND METHODS: From March 2003 to December 2009, 89 patients were included in this study. They were...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Korean Hip Society
2014
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4971123/ https://www.ncbi.nlm.nih.gov/pubmed/27536566 http://dx.doi.org/10.5371/hp.2014.26.2.99 |
_version_ | 1782446057567813632 |
---|---|
author | Kim, Yee-Suk Hur, Jae-Seung Hwang, Kyu-Tae Choi, Il-Yong Kim, Young-Ho |
author_facet | Kim, Yee-Suk Hur, Jae-Seung Hwang, Kyu-Tae Choi, Il-Yong Kim, Young-Ho |
author_sort | Kim, Yee-Suk |
collection | PubMed |
description | PURPOSE: The purpose of this study was to compare the outcomes of osteosynthesis using compression hip screw fixation versus bipolar hemiarthroplasty in AO type A2 intertrochanteric fractures. MATERIALS AND METHODS: From March 2003 to December 2009, 89 patients were included in this study. They were treated using compression hip screws (43 cases) or bipolar hemiarthroplasty (46 cases). The mean age of patients was 77.7 years (65-94 years) and the mean follow-up period was 5.9 years (1-8.3 years). For comparison of the outcomes in the two groups, statistical analyses were performed with parameters including anesthesia time, operation time, amount of transfusion, hospital stay, general complications, clinical outcome, time of partial weight-bearing using a walker, and radiological failure rate. RESULTS: Differences in the amount of transfusion, general complications, and clinical outcome (Merle d'Aubigné and Postel score) were not statistically significant between the two groups. The bipolar hemiarthroplasty group showed better results than the compression hip screw group for anesthesia time and the time of partial weight-bearing using a walker. Radiological failures were observed in hips in one case (2.2%) of bipolar hemiarthroplasty, and in four cases (9.3%) of compression hip screw fixation. CONCLUSION: Among elderly individuals with AO type A2 intertrochanteric fractures, patients treated with bipolar hemiarthroplasty were able to perform early ambulation. However, no significant difference in operation time, amount of postoperative transfusion, clinical results, hospital stay, and radiological failure rate was observed between the bipolar hemiarthroplasty and compression hip screw fixation groups. |
format | Online Article Text |
id | pubmed-4971123 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2014 |
publisher | Korean Hip Society |
record_format | MEDLINE/PubMed |
spelling | pubmed-49711232016-08-17 The Comparison of Compression Hip Screw and Bipolar Hemiarthroplasty for the Treatment of AO Type A2 Intertrochanteric Fractures Kim, Yee-Suk Hur, Jae-Seung Hwang, Kyu-Tae Choi, Il-Yong Kim, Young-Ho Hip Pelvis Original Article PURPOSE: The purpose of this study was to compare the outcomes of osteosynthesis using compression hip screw fixation versus bipolar hemiarthroplasty in AO type A2 intertrochanteric fractures. MATERIALS AND METHODS: From March 2003 to December 2009, 89 patients were included in this study. They were treated using compression hip screws (43 cases) or bipolar hemiarthroplasty (46 cases). The mean age of patients was 77.7 years (65-94 years) and the mean follow-up period was 5.9 years (1-8.3 years). For comparison of the outcomes in the two groups, statistical analyses were performed with parameters including anesthesia time, operation time, amount of transfusion, hospital stay, general complications, clinical outcome, time of partial weight-bearing using a walker, and radiological failure rate. RESULTS: Differences in the amount of transfusion, general complications, and clinical outcome (Merle d'Aubigné and Postel score) were not statistically significant between the two groups. The bipolar hemiarthroplasty group showed better results than the compression hip screw group for anesthesia time and the time of partial weight-bearing using a walker. Radiological failures were observed in hips in one case (2.2%) of bipolar hemiarthroplasty, and in four cases (9.3%) of compression hip screw fixation. CONCLUSION: Among elderly individuals with AO type A2 intertrochanteric fractures, patients treated with bipolar hemiarthroplasty were able to perform early ambulation. However, no significant difference in operation time, amount of postoperative transfusion, clinical results, hospital stay, and radiological failure rate was observed between the bipolar hemiarthroplasty and compression hip screw fixation groups. Korean Hip Society 2014-06 2014-06-30 /pmc/articles/PMC4971123/ /pubmed/27536566 http://dx.doi.org/10.5371/hp.2014.26.2.99 Text en Copyright © 2014 by Korean Hip Society http://creativecommons.org/licenses/by-nc/3.0/ This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/3.0/) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Original Article Kim, Yee-Suk Hur, Jae-Seung Hwang, Kyu-Tae Choi, Il-Yong Kim, Young-Ho The Comparison of Compression Hip Screw and Bipolar Hemiarthroplasty for the Treatment of AO Type A2 Intertrochanteric Fractures |
title | The Comparison of Compression Hip Screw and Bipolar Hemiarthroplasty for the Treatment of AO Type A2 Intertrochanteric Fractures |
title_full | The Comparison of Compression Hip Screw and Bipolar Hemiarthroplasty for the Treatment of AO Type A2 Intertrochanteric Fractures |
title_fullStr | The Comparison of Compression Hip Screw and Bipolar Hemiarthroplasty for the Treatment of AO Type A2 Intertrochanteric Fractures |
title_full_unstemmed | The Comparison of Compression Hip Screw and Bipolar Hemiarthroplasty for the Treatment of AO Type A2 Intertrochanteric Fractures |
title_short | The Comparison of Compression Hip Screw and Bipolar Hemiarthroplasty for the Treatment of AO Type A2 Intertrochanteric Fractures |
title_sort | comparison of compression hip screw and bipolar hemiarthroplasty for the treatment of ao type a2 intertrochanteric fractures |
topic | Original Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4971123/ https://www.ncbi.nlm.nih.gov/pubmed/27536566 http://dx.doi.org/10.5371/hp.2014.26.2.99 |
work_keys_str_mv | AT kimyeesuk thecomparisonofcompressionhipscrewandbipolarhemiarthroplastyforthetreatmentofaotypea2intertrochantericfractures AT hurjaeseung thecomparisonofcompressionhipscrewandbipolarhemiarthroplastyforthetreatmentofaotypea2intertrochantericfractures AT hwangkyutae thecomparisonofcompressionhipscrewandbipolarhemiarthroplastyforthetreatmentofaotypea2intertrochantericfractures AT choiilyong thecomparisonofcompressionhipscrewandbipolarhemiarthroplastyforthetreatmentofaotypea2intertrochantericfractures AT kimyoungho thecomparisonofcompressionhipscrewandbipolarhemiarthroplastyforthetreatmentofaotypea2intertrochantericfractures AT kimyeesuk comparisonofcompressionhipscrewandbipolarhemiarthroplastyforthetreatmentofaotypea2intertrochantericfractures AT hurjaeseung comparisonofcompressionhipscrewandbipolarhemiarthroplastyforthetreatmentofaotypea2intertrochantericfractures AT hwangkyutae comparisonofcompressionhipscrewandbipolarhemiarthroplastyforthetreatmentofaotypea2intertrochantericfractures AT choiilyong comparisonofcompressionhipscrewandbipolarhemiarthroplastyforthetreatmentofaotypea2intertrochantericfractures AT kimyoungho comparisonofcompressionhipscrewandbipolarhemiarthroplastyforthetreatmentofaotypea2intertrochantericfractures |