Cargando…
Fracture of the Greater Trochanter during Closed Reduction of Obturator Type Hip Dislocation
Obturator (Inferior) type dislocation of the hip joint is a rare and the fracture of greater trochanter during closed reduction for it has never been reported in literature. In this report, we present a case of a fracture of greater trochanter during difficult closed reduction which required operati...
Autores principales: | , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Korean Hip Society
2014
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4971405/ https://www.ncbi.nlm.nih.gov/pubmed/27536593 http://dx.doi.org/10.5371/hp.2014.26.4.275 |
Sumario: | Obturator (Inferior) type dislocation of the hip joint is a rare and the fracture of greater trochanter during closed reduction for it has never been reported in literature. In this report, we present a case of a fracture of greater trochanter during difficult closed reduction which required operative fixation. Surgeons need to be aware of this complication and excessive force for reduction should be avoided when treating of this type dislocation. |
---|