Cargando…
Novel no touch technique of saphenous vein harvesting: Is great graft patency rate provided?
Coronary artery bypass grafting surgery effectively relieves signs and symptoms of myocardial ischemia. The left internal thoracic artery (LITA) graft is the gold standard having 90–95% patency rate at 10 years, whereas only 50% of saphenous vein (SV) grafts are patent at 10 years. However, there is...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Medknow Publications & Media Pvt Ltd
2016
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4971977/ https://www.ncbi.nlm.nih.gov/pubmed/27397453 http://dx.doi.org/10.4103/0971-9784.185537 |
_version_ | 1782446193207410688 |
---|---|
author | Papakonstantinou, Nikolaos A. Baikoussis, Nikolaos G. Goudevenos, John Papadopoulos, George Apostolakis, Efstratios |
author_facet | Papakonstantinou, Nikolaos A. Baikoussis, Nikolaos G. Goudevenos, John Papadopoulos, George Apostolakis, Efstratios |
author_sort | Papakonstantinou, Nikolaos A. |
collection | PubMed |
description | Coronary artery bypass grafting surgery effectively relieves signs and symptoms of myocardial ischemia. The left internal thoracic artery (LITA) graft is the gold standard having 90–95% patency rate at 10 years, whereas only 50% of saphenous vein (SV) grafts are patent at 10 years. However, there is a novel “no touch” technique in order to harvest an SV complete with its cushion of surrounding tissue, thus maintaining its endothelium-intact. Significantly superior short- and long-term graft patency rates comparable to LITA grafts can be achieved. Consequently, the SV may be revived as an important conduit in coronary artery bypass surgery. |
format | Online Article Text |
id | pubmed-4971977 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2016 |
publisher | Medknow Publications & Media Pvt Ltd |
record_format | MEDLINE/PubMed |
spelling | pubmed-49719772016-08-25 Novel no touch technique of saphenous vein harvesting: Is great graft patency rate provided? Papakonstantinou, Nikolaos A. Baikoussis, Nikolaos G. Goudevenos, John Papadopoulos, George Apostolakis, Efstratios Ann Card Anaesth Review Article Coronary artery bypass grafting surgery effectively relieves signs and symptoms of myocardial ischemia. The left internal thoracic artery (LITA) graft is the gold standard having 90–95% patency rate at 10 years, whereas only 50% of saphenous vein (SV) grafts are patent at 10 years. However, there is a novel “no touch” technique in order to harvest an SV complete with its cushion of surrounding tissue, thus maintaining its endothelium-intact. Significantly superior short- and long-term graft patency rates comparable to LITA grafts can be achieved. Consequently, the SV may be revived as an important conduit in coronary artery bypass surgery. Medknow Publications & Media Pvt Ltd 2016 /pmc/articles/PMC4971977/ /pubmed/27397453 http://dx.doi.org/10.4103/0971-9784.185537 Text en Copyright: © 2016 Annals of Cardiac Anaesthesia http://creativecommons.org/licenses/by-nc-sa/3.0 This is an open access article distributed under the terms of the Creative Commons Attribution-NonCommercial-ShareAlike 3.0 License, which allows others to remix, tweak, and build upon the work non-commercially, as long as the author is credited and the new creations are licensed under the identical terms. |
spellingShingle | Review Article Papakonstantinou, Nikolaos A. Baikoussis, Nikolaos G. Goudevenos, John Papadopoulos, George Apostolakis, Efstratios Novel no touch technique of saphenous vein harvesting: Is great graft patency rate provided? |
title | Novel no touch technique of saphenous vein harvesting: Is great graft patency rate provided? |
title_full | Novel no touch technique of saphenous vein harvesting: Is great graft patency rate provided? |
title_fullStr | Novel no touch technique of saphenous vein harvesting: Is great graft patency rate provided? |
title_full_unstemmed | Novel no touch technique of saphenous vein harvesting: Is great graft patency rate provided? |
title_short | Novel no touch technique of saphenous vein harvesting: Is great graft patency rate provided? |
title_sort | novel no touch technique of saphenous vein harvesting: is great graft patency rate provided? |
topic | Review Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4971977/ https://www.ncbi.nlm.nih.gov/pubmed/27397453 http://dx.doi.org/10.4103/0971-9784.185537 |
work_keys_str_mv | AT papakonstantinounikolaosa novelnotouchtechniqueofsaphenousveinharvestingisgreatgraftpatencyrateprovided AT baikoussisnikolaosg novelnotouchtechniqueofsaphenousveinharvestingisgreatgraftpatencyrateprovided AT goudevenosjohn novelnotouchtechniqueofsaphenousveinharvestingisgreatgraftpatencyrateprovided AT papadopoulosgeorge novelnotouchtechniqueofsaphenousveinharvestingisgreatgraftpatencyrateprovided AT apostolakisefstratios novelnotouchtechniqueofsaphenousveinharvestingisgreatgraftpatencyrateprovided |