Novel no touch technique of saphenous vein harvesting: Is great graft patency rate provided?

Coronary artery bypass grafting surgery effectively relieves signs and symptoms of myocardial ischemia. The left internal thoracic artery (LITA) graft is the gold standard having 90–95% patency rate at 10 years, whereas only 50% of saphenous vein (SV) grafts are patent at 10 years. However, there is...

Descripción completa

Detalles Bibliográficos
Autores principales: Papakonstantinou, Nikolaos A., Baikoussis, Nikolaos G., Goudevenos, John, Papadopoulos, George, Apostolakis, Efstratios
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Medknow Publications & Media Pvt Ltd 2016
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4971977/
https://www.ncbi.nlm.nih.gov/pubmed/27397453
http://dx.doi.org/10.4103/0971-9784.185537
_version_ 1782446193207410688
author Papakonstantinou, Nikolaos A.
Baikoussis, Nikolaos G.
Goudevenos, John
Papadopoulos, George
Apostolakis, Efstratios
author_facet Papakonstantinou, Nikolaos A.
Baikoussis, Nikolaos G.
Goudevenos, John
Papadopoulos, George
Apostolakis, Efstratios
author_sort Papakonstantinou, Nikolaos A.
collection PubMed
description Coronary artery bypass grafting surgery effectively relieves signs and symptoms of myocardial ischemia. The left internal thoracic artery (LITA) graft is the gold standard having 90–95% patency rate at 10 years, whereas only 50% of saphenous vein (SV) grafts are patent at 10 years. However, there is a novel “no touch” technique in order to harvest an SV complete with its cushion of surrounding tissue, thus maintaining its endothelium-intact. Significantly superior short- and long-term graft patency rates comparable to LITA grafts can be achieved. Consequently, the SV may be revived as an important conduit in coronary artery bypass surgery.
format Online
Article
Text
id pubmed-4971977
institution National Center for Biotechnology Information
language English
publishDate 2016
publisher Medknow Publications & Media Pvt Ltd
record_format MEDLINE/PubMed
spelling pubmed-49719772016-08-25 Novel no touch technique of saphenous vein harvesting: Is great graft patency rate provided? Papakonstantinou, Nikolaos A. Baikoussis, Nikolaos G. Goudevenos, John Papadopoulos, George Apostolakis, Efstratios Ann Card Anaesth Review Article Coronary artery bypass grafting surgery effectively relieves signs and symptoms of myocardial ischemia. The left internal thoracic artery (LITA) graft is the gold standard having 90–95% patency rate at 10 years, whereas only 50% of saphenous vein (SV) grafts are patent at 10 years. However, there is a novel “no touch” technique in order to harvest an SV complete with its cushion of surrounding tissue, thus maintaining its endothelium-intact. Significantly superior short- and long-term graft patency rates comparable to LITA grafts can be achieved. Consequently, the SV may be revived as an important conduit in coronary artery bypass surgery. Medknow Publications & Media Pvt Ltd 2016 /pmc/articles/PMC4971977/ /pubmed/27397453 http://dx.doi.org/10.4103/0971-9784.185537 Text en Copyright: © 2016 Annals of Cardiac Anaesthesia http://creativecommons.org/licenses/by-nc-sa/3.0 This is an open access article distributed under the terms of the Creative Commons Attribution-NonCommercial-ShareAlike 3.0 License, which allows others to remix, tweak, and build upon the work non-commercially, as long as the author is credited and the new creations are licensed under the identical terms.
spellingShingle Review Article
Papakonstantinou, Nikolaos A.
Baikoussis, Nikolaos G.
Goudevenos, John
Papadopoulos, George
Apostolakis, Efstratios
Novel no touch technique of saphenous vein harvesting: Is great graft patency rate provided?
title Novel no touch technique of saphenous vein harvesting: Is great graft patency rate provided?
title_full Novel no touch technique of saphenous vein harvesting: Is great graft patency rate provided?
title_fullStr Novel no touch technique of saphenous vein harvesting: Is great graft patency rate provided?
title_full_unstemmed Novel no touch technique of saphenous vein harvesting: Is great graft patency rate provided?
title_short Novel no touch technique of saphenous vein harvesting: Is great graft patency rate provided?
title_sort novel no touch technique of saphenous vein harvesting: is great graft patency rate provided?
topic Review Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4971977/
https://www.ncbi.nlm.nih.gov/pubmed/27397453
http://dx.doi.org/10.4103/0971-9784.185537
work_keys_str_mv AT papakonstantinounikolaosa novelnotouchtechniqueofsaphenousveinharvestingisgreatgraftpatencyrateprovided
AT baikoussisnikolaosg novelnotouchtechniqueofsaphenousveinharvestingisgreatgraftpatencyrateprovided
AT goudevenosjohn novelnotouchtechniqueofsaphenousveinharvestingisgreatgraftpatencyrateprovided
AT papadopoulosgeorge novelnotouchtechniqueofsaphenousveinharvestingisgreatgraftpatencyrateprovided
AT apostolakisefstratios novelnotouchtechniqueofsaphenousveinharvestingisgreatgraftpatencyrateprovided