Cargando…

Relationship Between Respiratory Dynamics and Body Mass Index in Patients Undergoing General Anesthesia with Laryngeal Mask Airway (LMA) and Comparison Between Lithotomy and Supine Positions

BACKGROUND: This study aimed to compare respiratory dynamics in patients undergoing general anesthesia with a laryngeal mask airway (LMA) in lithotomy and supine positions and to validate the impact of operational position on effectiveness of LMA ventilation. MATERIAL/METHODS: A total of 90 patients...

Descripción completa

Detalles Bibliográficos
Autores principales: Zhao, Xiao, Huang, Shiwei, Wang, Zhaomin, Chen, Lianhua, Li, Shitong
Formato: Online Artículo Texto
Lenguaje:English
Publicado: International Scientific Literature, Inc. 2016
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4972071/
https://www.ncbi.nlm.nih.gov/pubmed/27476762
http://dx.doi.org/10.12659/MSM.897086
Descripción
Sumario:BACKGROUND: This study aimed to compare respiratory dynamics in patients undergoing general anesthesia with a laryngeal mask airway (LMA) in lithotomy and supine positions and to validate the impact of operational position on effectiveness of LMA ventilation. MATERIAL/METHODS: A total of 90 patients (age range, 18–65 years) who underwent general anesthesia were selected and divided into supine position (SP group) and lithotomy position groups (LP group). Vital signs and respiratory dynamic parameters of the 2 groups were measured at different time points and after implantation of an LMA. The arterial blood gas was monitored at 15 min after induction. The intraoperative changes of hemodynamic indexes and postoperative adverse reactions of LMA were recorded. The possible correlation between body mass index (BMI) and respiratory dynamic indexes was analyzed. RESULTS: With prolonged duration of the operation, the inspiratory plateau pressure (Pplat), inspiratory resistance (RI), and work of breathing (WOB) gradually increased, while chest-lung compliance (Compl) and partial pressure of carbon dioxide in end-expiratory gas (P(et)CO(2)) gradually decreased (all P value <0.05). The mean airway pressure (Pmean), Pplat, and expiratory resistance (Re) in the LP group were significantly higher than in the SP group (P<0.05), while the peak inspiratory flow (FImax), peak expiratory flow (FEmax), WOB, and Compl in the LP group were significantly lower than in the SP group (P<0.05). BMI was positively correlated with peak airway pressure (PIP/Ppeak), Pplat, and airway resistance (Raw) and was negatively correlated with Compl; the differences among patients in lithotomy position were more remarkable (P<0.05). CONCLUSIONS: The inspiratory plateau pressure and airway resistance increased with prolonged duration of the operation, accompanied by decreased chest-lung compliance. Peak airway pressure and airway resistance were positively correlated with BMI, and chest-lung compliance was negatively correlated with BMI. Changes among patients in lithotomy position were more remarkable than those in supine position.