Cargando…

Changes in Tip-Apex Distance by Position and Film Distance Measured by Picture Archiving and Communication System (PACS)

PURPOSE: The tip-apex distance (TAD) is used to predict the clinical outcome of intertrochanteric fracture fixation. We aimed to measure the changes in TAD by position and film distance using Picture Archiving and Communication System (PACS). MATERIALS AND METHODS: We used a femur replica with a 10°...

Descripción completa

Detalles Bibliográficos
Autores principales: Lee, Kyu Yeol, Kim, Sung Soo, Kim, Hyeon Jun, Ha, Dong Ho, Yoon, Hyung Min, Do, Hyun Su
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Korean Hip Society 2015
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4972618/
https://www.ncbi.nlm.nih.gov/pubmed/27536600
http://dx.doi.org/10.5371/hp.2015.27.1.36
_version_ 1782446272200835072
author Lee, Kyu Yeol
Kim, Sung Soo
Kim, Hyeon Jun
Ha, Dong Ho
Yoon, Hyung Min
Do, Hyun Su
author_facet Lee, Kyu Yeol
Kim, Sung Soo
Kim, Hyeon Jun
Ha, Dong Ho
Yoon, Hyung Min
Do, Hyun Su
author_sort Lee, Kyu Yeol
collection PubMed
description PURPOSE: The tip-apex distance (TAD) is used to predict the clinical outcome of intertrochanteric fracture fixation. We aimed to measure the changes in TAD by position and film distance using Picture Archiving and Communication System (PACS). MATERIALS AND METHODS: We used a femur replica with a 10° femoral neck anteversion and a 130° neck shaft angle. Proximal femoral nail antirotation nail and a helical blade were inserted into the replica. Radiographs were taken at the neutral position and after applying 10°, 20°, 30°, 40° internal/external rotation, 10° abduction, and 10° and 40° adduction to the mechanical axis. Radiographs were taken at the replica-film distance of 10 cm and 20 cm under the same conditions, mimicking the differences in Focus-film distance (FFD), which reflect the patient's contour in clinical settings. A radiologist and an orthopedic surgeon measured the TAD twice using PACS. The average error was 2 mm (4.5%) and the standard error was ±3.04. TADs in the neutral position constituted the standard values to measure the relative errors. RESULTS: TADs increased with an increase in the external rotation and abduction of the replica. TADs decreased with an increase in the internal rotation and adduction of the replica. For comparable measurements, relative errors were higher at FFDs of 20 cm compared to FFDs of 10 cm. CONCLUSION: Since the femur is internally rotated and adducted for reduction, orthopedic surgeons would assess the lag screw to be closer to the apex of femur on intraoperative radiographs. To have a correct measurement of the TAD after fixation of intertrochanteric fractures, radiographs should be taken in neutral position and measurement errors should be considered based on the patient's size.
format Online
Article
Text
id pubmed-4972618
institution National Center for Biotechnology Information
language English
publishDate 2015
publisher Korean Hip Society
record_format MEDLINE/PubMed
spelling pubmed-49726182016-08-17 Changes in Tip-Apex Distance by Position and Film Distance Measured by Picture Archiving and Communication System (PACS) Lee, Kyu Yeol Kim, Sung Soo Kim, Hyeon Jun Ha, Dong Ho Yoon, Hyung Min Do, Hyun Su Hip Pelvis Original Article PURPOSE: The tip-apex distance (TAD) is used to predict the clinical outcome of intertrochanteric fracture fixation. We aimed to measure the changes in TAD by position and film distance using Picture Archiving and Communication System (PACS). MATERIALS AND METHODS: We used a femur replica with a 10° femoral neck anteversion and a 130° neck shaft angle. Proximal femoral nail antirotation nail and a helical blade were inserted into the replica. Radiographs were taken at the neutral position and after applying 10°, 20°, 30°, 40° internal/external rotation, 10° abduction, and 10° and 40° adduction to the mechanical axis. Radiographs were taken at the replica-film distance of 10 cm and 20 cm under the same conditions, mimicking the differences in Focus-film distance (FFD), which reflect the patient's contour in clinical settings. A radiologist and an orthopedic surgeon measured the TAD twice using PACS. The average error was 2 mm (4.5%) and the standard error was ±3.04. TADs in the neutral position constituted the standard values to measure the relative errors. RESULTS: TADs increased with an increase in the external rotation and abduction of the replica. TADs decreased with an increase in the internal rotation and adduction of the replica. For comparable measurements, relative errors were higher at FFDs of 20 cm compared to FFDs of 10 cm. CONCLUSION: Since the femur is internally rotated and adducted for reduction, orthopedic surgeons would assess the lag screw to be closer to the apex of femur on intraoperative radiographs. To have a correct measurement of the TAD after fixation of intertrochanteric fractures, radiographs should be taken in neutral position and measurement errors should be considered based on the patient's size. Korean Hip Society 2015-03 2015-03-31 /pmc/articles/PMC4972618/ /pubmed/27536600 http://dx.doi.org/10.5371/hp.2015.27.1.36 Text en Copyright © 2015 by Korean Hip Society http://creativecommons.org/licenses/by-nc/3.0/ This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/3.0/) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Original Article
Lee, Kyu Yeol
Kim, Sung Soo
Kim, Hyeon Jun
Ha, Dong Ho
Yoon, Hyung Min
Do, Hyun Su
Changes in Tip-Apex Distance by Position and Film Distance Measured by Picture Archiving and Communication System (PACS)
title Changes in Tip-Apex Distance by Position and Film Distance Measured by Picture Archiving and Communication System (PACS)
title_full Changes in Tip-Apex Distance by Position and Film Distance Measured by Picture Archiving and Communication System (PACS)
title_fullStr Changes in Tip-Apex Distance by Position and Film Distance Measured by Picture Archiving and Communication System (PACS)
title_full_unstemmed Changes in Tip-Apex Distance by Position and Film Distance Measured by Picture Archiving and Communication System (PACS)
title_short Changes in Tip-Apex Distance by Position and Film Distance Measured by Picture Archiving and Communication System (PACS)
title_sort changes in tip-apex distance by position and film distance measured by picture archiving and communication system (pacs)
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4972618/
https://www.ncbi.nlm.nih.gov/pubmed/27536600
http://dx.doi.org/10.5371/hp.2015.27.1.36
work_keys_str_mv AT leekyuyeol changesintipapexdistancebypositionandfilmdistancemeasuredbypicturearchivingandcommunicationsystempacs
AT kimsungsoo changesintipapexdistancebypositionandfilmdistancemeasuredbypicturearchivingandcommunicationsystempacs
AT kimhyeonjun changesintipapexdistancebypositionandfilmdistancemeasuredbypicturearchivingandcommunicationsystempacs
AT hadongho changesintipapexdistancebypositionandfilmdistancemeasuredbypicturearchivingandcommunicationsystempacs
AT yoonhyungmin changesintipapexdistancebypositionandfilmdistancemeasuredbypicturearchivingandcommunicationsystempacs
AT dohyunsu changesintipapexdistancebypositionandfilmdistancemeasuredbypicturearchivingandcommunicationsystempacs