Changes in Tip-Apex Distance by Position and Film Distance Measured by Picture Archiving and Communication System (PACS)
PURPOSE: The tip-apex distance (TAD) is used to predict the clinical outcome of intertrochanteric fracture fixation. We aimed to measure the changes in TAD by position and film distance using Picture Archiving and Communication System (PACS). MATERIALS AND METHODS: We used a femur replica with a 10°...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Korean Hip Society
2015
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4972618/ https://www.ncbi.nlm.nih.gov/pubmed/27536600 http://dx.doi.org/10.5371/hp.2015.27.1.36 |
_version_ | 1782446272200835072 |
---|---|
author | Lee, Kyu Yeol Kim, Sung Soo Kim, Hyeon Jun Ha, Dong Ho Yoon, Hyung Min Do, Hyun Su |
author_facet | Lee, Kyu Yeol Kim, Sung Soo Kim, Hyeon Jun Ha, Dong Ho Yoon, Hyung Min Do, Hyun Su |
author_sort | Lee, Kyu Yeol |
collection | PubMed |
description | PURPOSE: The tip-apex distance (TAD) is used to predict the clinical outcome of intertrochanteric fracture fixation. We aimed to measure the changes in TAD by position and film distance using Picture Archiving and Communication System (PACS). MATERIALS AND METHODS: We used a femur replica with a 10° femoral neck anteversion and a 130° neck shaft angle. Proximal femoral nail antirotation nail and a helical blade were inserted into the replica. Radiographs were taken at the neutral position and after applying 10°, 20°, 30°, 40° internal/external rotation, 10° abduction, and 10° and 40° adduction to the mechanical axis. Radiographs were taken at the replica-film distance of 10 cm and 20 cm under the same conditions, mimicking the differences in Focus-film distance (FFD), which reflect the patient's contour in clinical settings. A radiologist and an orthopedic surgeon measured the TAD twice using PACS. The average error was 2 mm (4.5%) and the standard error was ±3.04. TADs in the neutral position constituted the standard values to measure the relative errors. RESULTS: TADs increased with an increase in the external rotation and abduction of the replica. TADs decreased with an increase in the internal rotation and adduction of the replica. For comparable measurements, relative errors were higher at FFDs of 20 cm compared to FFDs of 10 cm. CONCLUSION: Since the femur is internally rotated and adducted for reduction, orthopedic surgeons would assess the lag screw to be closer to the apex of femur on intraoperative radiographs. To have a correct measurement of the TAD after fixation of intertrochanteric fractures, radiographs should be taken in neutral position and measurement errors should be considered based on the patient's size. |
format | Online Article Text |
id | pubmed-4972618 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2015 |
publisher | Korean Hip Society |
record_format | MEDLINE/PubMed |
spelling | pubmed-49726182016-08-17 Changes in Tip-Apex Distance by Position and Film Distance Measured by Picture Archiving and Communication System (PACS) Lee, Kyu Yeol Kim, Sung Soo Kim, Hyeon Jun Ha, Dong Ho Yoon, Hyung Min Do, Hyun Su Hip Pelvis Original Article PURPOSE: The tip-apex distance (TAD) is used to predict the clinical outcome of intertrochanteric fracture fixation. We aimed to measure the changes in TAD by position and film distance using Picture Archiving and Communication System (PACS). MATERIALS AND METHODS: We used a femur replica with a 10° femoral neck anteversion and a 130° neck shaft angle. Proximal femoral nail antirotation nail and a helical blade were inserted into the replica. Radiographs were taken at the neutral position and after applying 10°, 20°, 30°, 40° internal/external rotation, 10° abduction, and 10° and 40° adduction to the mechanical axis. Radiographs were taken at the replica-film distance of 10 cm and 20 cm under the same conditions, mimicking the differences in Focus-film distance (FFD), which reflect the patient's contour in clinical settings. A radiologist and an orthopedic surgeon measured the TAD twice using PACS. The average error was 2 mm (4.5%) and the standard error was ±3.04. TADs in the neutral position constituted the standard values to measure the relative errors. RESULTS: TADs increased with an increase in the external rotation and abduction of the replica. TADs decreased with an increase in the internal rotation and adduction of the replica. For comparable measurements, relative errors were higher at FFDs of 20 cm compared to FFDs of 10 cm. CONCLUSION: Since the femur is internally rotated and adducted for reduction, orthopedic surgeons would assess the lag screw to be closer to the apex of femur on intraoperative radiographs. To have a correct measurement of the TAD after fixation of intertrochanteric fractures, radiographs should be taken in neutral position and measurement errors should be considered based on the patient's size. Korean Hip Society 2015-03 2015-03-31 /pmc/articles/PMC4972618/ /pubmed/27536600 http://dx.doi.org/10.5371/hp.2015.27.1.36 Text en Copyright © 2015 by Korean Hip Society http://creativecommons.org/licenses/by-nc/3.0/ This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/3.0/) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Original Article Lee, Kyu Yeol Kim, Sung Soo Kim, Hyeon Jun Ha, Dong Ho Yoon, Hyung Min Do, Hyun Su Changes in Tip-Apex Distance by Position and Film Distance Measured by Picture Archiving and Communication System (PACS) |
title | Changes in Tip-Apex Distance by Position and Film Distance Measured by Picture Archiving and Communication System (PACS) |
title_full | Changes in Tip-Apex Distance by Position and Film Distance Measured by Picture Archiving and Communication System (PACS) |
title_fullStr | Changes in Tip-Apex Distance by Position and Film Distance Measured by Picture Archiving and Communication System (PACS) |
title_full_unstemmed | Changes in Tip-Apex Distance by Position and Film Distance Measured by Picture Archiving and Communication System (PACS) |
title_short | Changes in Tip-Apex Distance by Position and Film Distance Measured by Picture Archiving and Communication System (PACS) |
title_sort | changes in tip-apex distance by position and film distance measured by picture archiving and communication system (pacs) |
topic | Original Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4972618/ https://www.ncbi.nlm.nih.gov/pubmed/27536600 http://dx.doi.org/10.5371/hp.2015.27.1.36 |
work_keys_str_mv | AT leekyuyeol changesintipapexdistancebypositionandfilmdistancemeasuredbypicturearchivingandcommunicationsystempacs AT kimsungsoo changesintipapexdistancebypositionandfilmdistancemeasuredbypicturearchivingandcommunicationsystempacs AT kimhyeonjun changesintipapexdistancebypositionandfilmdistancemeasuredbypicturearchivingandcommunicationsystempacs AT hadongho changesintipapexdistancebypositionandfilmdistancemeasuredbypicturearchivingandcommunicationsystempacs AT yoonhyungmin changesintipapexdistancebypositionandfilmdistancemeasuredbypicturearchivingandcommunicationsystempacs AT dohyunsu changesintipapexdistancebypositionandfilmdistancemeasuredbypicturearchivingandcommunicationsystempacs |