Cargando…
Visualization of precut DSAEK and pre-stripped DMEK donor corneas by intraoperative optical coherence tomography using the RESCAN 700
BACKGROUND: To report the feasibility of intraoperative spectral domain optical coherence tomography (OCT) using the RESCAN 700 for the visualization and evaluation of precut Descemet’s stripping automated endothelial keratoplasty (DSAEK) and prestripped Descemet’s membrane endothelial keratoplasty...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
BioMed Central
2016
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4973550/ https://www.ncbi.nlm.nih.gov/pubmed/27491407 http://dx.doi.org/10.1186/s12886-016-0308-z |
_version_ | 1782446418288443392 |
---|---|
author | Kobayashi, Akira Yokogawa, Hideaki Mori, Natsuko Sugiyama, Kazuhisa |
author_facet | Kobayashi, Akira Yokogawa, Hideaki Mori, Natsuko Sugiyama, Kazuhisa |
author_sort | Kobayashi, Akira |
collection | PubMed |
description | BACKGROUND: To report the feasibility of intraoperative spectral domain optical coherence tomography (OCT) using the RESCAN 700 for the visualization and evaluation of precut Descemet’s stripping automated endothelial keratoplasty (DSAEK) and prestripped Descemet’s membrane endothelial keratoplasty (DMEK) donor tissue. METHODS: Precut DSAEK (n = 11), prestripped DMEK (n = 4) preserved in a viewing chamber were examined by intraoperative OCT. Wholly intact donor corneas for penetrating keratoplasty (PK) (n = 8) were also examined as controls. The obtained images were analyzed qualitatively for characteristics of each type of donor. RESULTS: For each type of donor, characteristic images were consistently obtained by intraoperative OCT in both the front and back views through the viewing chamber. In wholly intact donors for PK, appearance of normal corneal curvature and stromal texture with high reflectivity of epithelium and endothelium cell layers were clearly visualized. In precut DSAEK donors, precut lines were characteristically visualized in addition to the intact donor cornea images. In prestripped DMEK donors, identical OCT images to the intact donor cornea were noted when observed from the anterior surface. However, peripheral partial detachments of Descemet’s membrane were characteristically observed in all prestripped DMEK donors when viewed from the back of the viewing chamber. CONCLUSION: Rapid visualization and rough evaluation of donor tissues for PK, precut DSAEK and prestripped DMEK donor corneas by intraoperative OCT was consistently possible through the viewing chamber. Therefore, this device may be used as an alternative of AS-OCT when the eyebank does not have their own AS-OCT. Although the peripheral detachment in DMEK donors are quite common and clinically non-problematic in DMEK donor quality and subsequent DMEK surgeries, it may be useful to distinguish between wholly intact PK donors and prestripped DMEK donors, enabling to prevent mix-ups of donors, especially when several different types of keratoplasties are scheduled in a same day in one operating theater. |
format | Online Article Text |
id | pubmed-4973550 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2016 |
publisher | BioMed Central |
record_format | MEDLINE/PubMed |
spelling | pubmed-49735502016-08-05 Visualization of precut DSAEK and pre-stripped DMEK donor corneas by intraoperative optical coherence tomography using the RESCAN 700 Kobayashi, Akira Yokogawa, Hideaki Mori, Natsuko Sugiyama, Kazuhisa BMC Ophthalmol Research Article BACKGROUND: To report the feasibility of intraoperative spectral domain optical coherence tomography (OCT) using the RESCAN 700 for the visualization and evaluation of precut Descemet’s stripping automated endothelial keratoplasty (DSAEK) and prestripped Descemet’s membrane endothelial keratoplasty (DMEK) donor tissue. METHODS: Precut DSAEK (n = 11), prestripped DMEK (n = 4) preserved in a viewing chamber were examined by intraoperative OCT. Wholly intact donor corneas for penetrating keratoplasty (PK) (n = 8) were also examined as controls. The obtained images were analyzed qualitatively for characteristics of each type of donor. RESULTS: For each type of donor, characteristic images were consistently obtained by intraoperative OCT in both the front and back views through the viewing chamber. In wholly intact donors for PK, appearance of normal corneal curvature and stromal texture with high reflectivity of epithelium and endothelium cell layers were clearly visualized. In precut DSAEK donors, precut lines were characteristically visualized in addition to the intact donor cornea images. In prestripped DMEK donors, identical OCT images to the intact donor cornea were noted when observed from the anterior surface. However, peripheral partial detachments of Descemet’s membrane were characteristically observed in all prestripped DMEK donors when viewed from the back of the viewing chamber. CONCLUSION: Rapid visualization and rough evaluation of donor tissues for PK, precut DSAEK and prestripped DMEK donor corneas by intraoperative OCT was consistently possible through the viewing chamber. Therefore, this device may be used as an alternative of AS-OCT when the eyebank does not have their own AS-OCT. Although the peripheral detachment in DMEK donors are quite common and clinically non-problematic in DMEK donor quality and subsequent DMEK surgeries, it may be useful to distinguish between wholly intact PK donors and prestripped DMEK donors, enabling to prevent mix-ups of donors, especially when several different types of keratoplasties are scheduled in a same day in one operating theater. BioMed Central 2016-08-04 /pmc/articles/PMC4973550/ /pubmed/27491407 http://dx.doi.org/10.1186/s12886-016-0308-z Text en © Kobayashi et al. 2016 Open AccessThis article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated. |
spellingShingle | Research Article Kobayashi, Akira Yokogawa, Hideaki Mori, Natsuko Sugiyama, Kazuhisa Visualization of precut DSAEK and pre-stripped DMEK donor corneas by intraoperative optical coherence tomography using the RESCAN 700 |
title | Visualization of precut DSAEK and pre-stripped DMEK donor corneas by intraoperative optical coherence tomography using the RESCAN 700 |
title_full | Visualization of precut DSAEK and pre-stripped DMEK donor corneas by intraoperative optical coherence tomography using the RESCAN 700 |
title_fullStr | Visualization of precut DSAEK and pre-stripped DMEK donor corneas by intraoperative optical coherence tomography using the RESCAN 700 |
title_full_unstemmed | Visualization of precut DSAEK and pre-stripped DMEK donor corneas by intraoperative optical coherence tomography using the RESCAN 700 |
title_short | Visualization of precut DSAEK and pre-stripped DMEK donor corneas by intraoperative optical coherence tomography using the RESCAN 700 |
title_sort | visualization of precut dsaek and pre-stripped dmek donor corneas by intraoperative optical coherence tomography using the rescan 700 |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4973550/ https://www.ncbi.nlm.nih.gov/pubmed/27491407 http://dx.doi.org/10.1186/s12886-016-0308-z |
work_keys_str_mv | AT kobayashiakira visualizationofprecutdsaekandprestrippeddmekdonorcorneasbyintraoperativeopticalcoherencetomographyusingtherescan700 AT yokogawahideaki visualizationofprecutdsaekandprestrippeddmekdonorcorneasbyintraoperativeopticalcoherencetomographyusingtherescan700 AT morinatsuko visualizationofprecutdsaekandprestrippeddmekdonorcorneasbyintraoperativeopticalcoherencetomographyusingtherescan700 AT sugiyamakazuhisa visualizationofprecutdsaekandprestrippeddmekdonorcorneasbyintraoperativeopticalcoherencetomographyusingtherescan700 |