Cargando…

Constructal approach to bio-engineering: the ocular anterior chamber temperature

The aim of this work was to analyse the pressure inside the eyes anterior chamber, namedintraocular pressure (IOP), in relation to the biomechanical properties of corneas. The approach used was based on the constructal law, recently introduced in vision analysis. Results were expressed as the relati...

Descripción completa

Detalles Bibliográficos
Autores principales: Lucia, Umberto, Grisolia, Giulia, Dolcino, Daniela, Astori, Maria Rosa, Massa, Eugenio, Ponzetto, Antonio
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Nature Publishing Group 2016
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4974607/
https://www.ncbi.nlm.nih.gov/pubmed/27492652
http://dx.doi.org/10.1038/srep31099
_version_ 1782446573250150400
author Lucia, Umberto
Grisolia, Giulia
Dolcino, Daniela
Astori, Maria Rosa
Massa, Eugenio
Ponzetto, Antonio
author_facet Lucia, Umberto
Grisolia, Giulia
Dolcino, Daniela
Astori, Maria Rosa
Massa, Eugenio
Ponzetto, Antonio
author_sort Lucia, Umberto
collection PubMed
description The aim of this work was to analyse the pressure inside the eyes anterior chamber, namedintraocular pressure (IOP), in relation to the biomechanical properties of corneas. The approach used was based on the constructal law, recently introduced in vision analysis. Results were expressed as the relation between the temperature of the ocular anterior chamber and the biomechanical properties of the cornea. The IOP, the elastic properties of the cornea, and the related refractive properties of the eye were demonstrated to be dependent on the temperature of the ocular anterior chamber. These results could lead to new perspectives for experimental analysis of the IOP in relation to the properties of the cornea.
format Online
Article
Text
id pubmed-4974607
institution National Center for Biotechnology Information
language English
publishDate 2016
publisher Nature Publishing Group
record_format MEDLINE/PubMed
spelling pubmed-49746072016-08-17 Constructal approach to bio-engineering: the ocular anterior chamber temperature Lucia, Umberto Grisolia, Giulia Dolcino, Daniela Astori, Maria Rosa Massa, Eugenio Ponzetto, Antonio Sci Rep Article The aim of this work was to analyse the pressure inside the eyes anterior chamber, namedintraocular pressure (IOP), in relation to the biomechanical properties of corneas. The approach used was based on the constructal law, recently introduced in vision analysis. Results were expressed as the relation between the temperature of the ocular anterior chamber and the biomechanical properties of the cornea. The IOP, the elastic properties of the cornea, and the related refractive properties of the eye were demonstrated to be dependent on the temperature of the ocular anterior chamber. These results could lead to new perspectives for experimental analysis of the IOP in relation to the properties of the cornea. Nature Publishing Group 2016-08-05 /pmc/articles/PMC4974607/ /pubmed/27492652 http://dx.doi.org/10.1038/srep31099 Text en Copyright © 2016, The Author(s) http://creativecommons.org/licenses/by/4.0/ This work is licensed under a Creative Commons Attribution 4.0 International License. The images or other third party material in this article are included in the article’s Creative Commons license, unless indicated otherwise in the credit line; if the material is not included under the Creative Commons license, users will need to obtain permission from the license holder to reproduce the material. To view a copy of this license, visit http://creativecommons.org/licenses/by/4.0/
spellingShingle Article
Lucia, Umberto
Grisolia, Giulia
Dolcino, Daniela
Astori, Maria Rosa
Massa, Eugenio
Ponzetto, Antonio
Constructal approach to bio-engineering: the ocular anterior chamber temperature
title Constructal approach to bio-engineering: the ocular anterior chamber temperature
title_full Constructal approach to bio-engineering: the ocular anterior chamber temperature
title_fullStr Constructal approach to bio-engineering: the ocular anterior chamber temperature
title_full_unstemmed Constructal approach to bio-engineering: the ocular anterior chamber temperature
title_short Constructal approach to bio-engineering: the ocular anterior chamber temperature
title_sort constructal approach to bio-engineering: the ocular anterior chamber temperature
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4974607/
https://www.ncbi.nlm.nih.gov/pubmed/27492652
http://dx.doi.org/10.1038/srep31099
work_keys_str_mv AT luciaumberto constructalapproachtobioengineeringtheocularanteriorchambertemperature
AT grisoliagiulia constructalapproachtobioengineeringtheocularanteriorchambertemperature
AT dolcinodaniela constructalapproachtobioengineeringtheocularanteriorchambertemperature
AT astorimariarosa constructalapproachtobioengineeringtheocularanteriorchambertemperature
AT massaeugenio constructalapproachtobioengineeringtheocularanteriorchambertemperature
AT ponzettoantonio constructalapproachtobioengineeringtheocularanteriorchambertemperature