Cargando…

Abdo-Man: a 3D-printed anthropomorphic phantom for validating quantitative SIRT

BACKGROUND: The use of selective internal radiation therapy (SIRT) is rapidly increasing, and the need for quantification and dosimetry is becoming more widespread to facilitate treatment planning and verification. The aim of this project was to develop an anthropomorphic phantom that can be used as...

Descripción completa

Detalles Bibliográficos
Autores principales: Gear, Jonathan I., Cummings, Craig, Craig, Allison J., Divoli, Antigoni, Long, Clive D. C., Tapner, Michael, Flux, Glenn D.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Springer International Publishing 2016
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4975728/
https://www.ncbi.nlm.nih.gov/pubmed/27495914
http://dx.doi.org/10.1186/s40658-016-0151-6
_version_ 1782446760863465472
author Gear, Jonathan I.
Cummings, Craig
Craig, Allison J.
Divoli, Antigoni
Long, Clive D. C.
Tapner, Michael
Flux, Glenn D.
author_facet Gear, Jonathan I.
Cummings, Craig
Craig, Allison J.
Divoli, Antigoni
Long, Clive D. C.
Tapner, Michael
Flux, Glenn D.
author_sort Gear, Jonathan I.
collection PubMed
description BACKGROUND: The use of selective internal radiation therapy (SIRT) is rapidly increasing, and the need for quantification and dosimetry is becoming more widespread to facilitate treatment planning and verification. The aim of this project was to develop an anthropomorphic phantom that can be used as a validation tool for post-SIRT imaging and its application to dosimetry. METHOD: The phantom design was based on anatomical data obtained from a T1-weighted volume-interpolated breath-hold examination (VIBE) on a Siemens Aera 1.5 T MRI scanner. The liver, lungs and abdominal trunk were segmented using the Hermes image processing workstation. Organ volumes were then uploaded to the Delft Visualization and Image processing Development Environment for smoothing and surface rendering. Triangular meshes defining the iso-surfaces were saved as stereo lithography (STL) files and imported into the Autodesk® Meshmixer software. Organ volumes were subtracted from the abdomen and a removable base designed to allow access to the liver cavity. Connection points for placing lesion inserts and filling holes were also included. The phantom was manufactured using a Stratasys Connex3 PolyJet 3D printer. The printer uses stereolithography technology combined with ink jet printing. Print material is a solid acrylic plastic, with similar properties to polymethylmethacrylate (PMMA). RESULTS: Measured Hounsfield units and calculated attenuation coefficients of the material were shown to also be similar to PMMA. Total print time for the phantom was approximately 5 days. Initial scans of the phantom have been performed with Y-90 bremsstrahlung SPECT/CT, Y-90 PET/CT and Tc-99m SPECT/CT. The CT component of these images compared well with the original anatomical reference, and measurements of volume agreed to within 9 %. Quantitative analysis of the phantom was performed using all three imaging techniques. Lesion and normal liver absorbed doses were calculated from the quantitative images in three dimensions using the local deposition method. CONCLUSIONS: 3D printing is a flexible and cost-efficient technology for manufacture of anthropomorphic phantom. Application of such phantoms will enable quantitative imaging and dosimetry methodologies to be evaluated, which with optimisation could help improve outcome for patients.
format Online
Article
Text
id pubmed-4975728
institution National Center for Biotechnology Information
language English
publishDate 2016
publisher Springer International Publishing
record_format MEDLINE/PubMed
spelling pubmed-49757282016-08-18 Abdo-Man: a 3D-printed anthropomorphic phantom for validating quantitative SIRT Gear, Jonathan I. Cummings, Craig Craig, Allison J. Divoli, Antigoni Long, Clive D. C. Tapner, Michael Flux, Glenn D. EJNMMI Phys Original Research BACKGROUND: The use of selective internal radiation therapy (SIRT) is rapidly increasing, and the need for quantification and dosimetry is becoming more widespread to facilitate treatment planning and verification. The aim of this project was to develop an anthropomorphic phantom that can be used as a validation tool for post-SIRT imaging and its application to dosimetry. METHOD: The phantom design was based on anatomical data obtained from a T1-weighted volume-interpolated breath-hold examination (VIBE) on a Siemens Aera 1.5 T MRI scanner. The liver, lungs and abdominal trunk were segmented using the Hermes image processing workstation. Organ volumes were then uploaded to the Delft Visualization and Image processing Development Environment for smoothing and surface rendering. Triangular meshes defining the iso-surfaces were saved as stereo lithography (STL) files and imported into the Autodesk® Meshmixer software. Organ volumes were subtracted from the abdomen and a removable base designed to allow access to the liver cavity. Connection points for placing lesion inserts and filling holes were also included. The phantom was manufactured using a Stratasys Connex3 PolyJet 3D printer. The printer uses stereolithography technology combined with ink jet printing. Print material is a solid acrylic plastic, with similar properties to polymethylmethacrylate (PMMA). RESULTS: Measured Hounsfield units and calculated attenuation coefficients of the material were shown to also be similar to PMMA. Total print time for the phantom was approximately 5 days. Initial scans of the phantom have been performed with Y-90 bremsstrahlung SPECT/CT, Y-90 PET/CT and Tc-99m SPECT/CT. The CT component of these images compared well with the original anatomical reference, and measurements of volume agreed to within 9 %. Quantitative analysis of the phantom was performed using all three imaging techniques. Lesion and normal liver absorbed doses were calculated from the quantitative images in three dimensions using the local deposition method. CONCLUSIONS: 3D printing is a flexible and cost-efficient technology for manufacture of anthropomorphic phantom. Application of such phantoms will enable quantitative imaging and dosimetry methodologies to be evaluated, which with optimisation could help improve outcome for patients. Springer International Publishing 2016-08-05 /pmc/articles/PMC4975728/ /pubmed/27495914 http://dx.doi.org/10.1186/s40658-016-0151-6 Text en © Gear et al. 2016 Open AccessThis article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made.
spellingShingle Original Research
Gear, Jonathan I.
Cummings, Craig
Craig, Allison J.
Divoli, Antigoni
Long, Clive D. C.
Tapner, Michael
Flux, Glenn D.
Abdo-Man: a 3D-printed anthropomorphic phantom for validating quantitative SIRT
title Abdo-Man: a 3D-printed anthropomorphic phantom for validating quantitative SIRT
title_full Abdo-Man: a 3D-printed anthropomorphic phantom for validating quantitative SIRT
title_fullStr Abdo-Man: a 3D-printed anthropomorphic phantom for validating quantitative SIRT
title_full_unstemmed Abdo-Man: a 3D-printed anthropomorphic phantom for validating quantitative SIRT
title_short Abdo-Man: a 3D-printed anthropomorphic phantom for validating quantitative SIRT
title_sort abdo-man: a 3d-printed anthropomorphic phantom for validating quantitative sirt
topic Original Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4975728/
https://www.ncbi.nlm.nih.gov/pubmed/27495914
http://dx.doi.org/10.1186/s40658-016-0151-6
work_keys_str_mv AT gearjonathani abdomana3dprintedanthropomorphicphantomforvalidatingquantitativesirt
AT cummingscraig abdomana3dprintedanthropomorphicphantomforvalidatingquantitativesirt
AT craigallisonj abdomana3dprintedanthropomorphicphantomforvalidatingquantitativesirt
AT divoliantigoni abdomana3dprintedanthropomorphicphantomforvalidatingquantitativesirt
AT longclivedc abdomana3dprintedanthropomorphicphantomforvalidatingquantitativesirt
AT tapnermichael abdomana3dprintedanthropomorphicphantomforvalidatingquantitativesirt
AT fluxglennd abdomana3dprintedanthropomorphicphantomforvalidatingquantitativesirt