Effect of dosimeter’s position on occupational radiation extremity dose measurement for nuclear medicine workers during (18)F-FDG preparation for PET/CT

BACKGROUND: The recent spread of positron emission tomography-computed tomography (PET/CT) poses extremity dosimetry challenges. The question arose whether the radiation dose measured by the ring thermoluminescent dosimeter usually worn on the proximal phalanx (P1) of the index finger measures doses...

Descripción completa

Detalles Bibliográficos
Autores principales: Salesses, Fabien, Perez, Paul, Maillard, Aline E., Blanchard, Julie, Mallard, Sabine, Bordenave, Laurence
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Springer International Publishing 2016
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4975735/
https://www.ncbi.nlm.nih.gov/pubmed/27495913
http://dx.doi.org/10.1186/s40658-016-0152-5
_version_ 1782446762477223936
author Salesses, Fabien
Perez, Paul
Maillard, Aline E.
Blanchard, Julie
Mallard, Sabine
Bordenave, Laurence
author_facet Salesses, Fabien
Perez, Paul
Maillard, Aline E.
Blanchard, Julie
Mallard, Sabine
Bordenave, Laurence
author_sort Salesses, Fabien
collection PubMed
description BACKGROUND: The recent spread of positron emission tomography-computed tomography (PET/CT) poses extremity dosimetry challenges. The question arose whether the radiation dose measured by the ring thermoluminescent dosimeter usually worn on the proximal phalanx (P1) of the index finger measures doses that are representative of the true doses received by the upper extremities of the operators. A prospective individual dosimetry study was performed in which the personal equivalent dose Hp (0.07) received during a specific 2-[(18)F]fluoro-2-deoxy-d-glucose ((18)F-FDG) manual dose-dispensing procedure was measured in a paired design by two operational personal electronic dosimeters fitted on the palm side of the index finger, namely in the P1 and distal phalanx (P3) positions. The study participants were ten nuclear medicine technologists working in two nuclear medicine departments. The personal equivalent radiation doses received by the palm side of the proximal phalanx of the index finger [Hp (0.07)(P1)] and that received by the distal phalanx [Hp (0.07)(P3)] were compared. RESULTS: The median Hp (0.07)(P3)/Hp (0.07)(P1) ratio per participant varied between 1.0 and 2.5 (based on 23 to 31 measurements per participant). The 271 paired measurements revealed a crude Hp (0.07)(P3)/Hp (0.07)(P1) ratio of 1.67, significantly different from 1 (p = 0.0004, 95 % CI [1.35–2.07]). When adjusted on participant’s gender and mother vial activity, the ratio was similar (1.53, p = 0.003, 95 % CI [1.22–1.92]). CONCLUSIONS: The study demonstrated a significant disparity that may exist between the radiation doses measured in the P1 and P3 positions of operators during (18)F-FDG manipulation. These findings emphasize the importance of performing workplace dosimetry studies adapted to each radiopharmaceutical and manipulation thereof, aiming to guarantee optimal workers’ dosimetry monitoring schemes. TRIAL REGISTRATION: Hospital Nursing and Paramedical Research Program (PHRIP, 2011–2013) from the French Ministry of Health (DGOS), http://social-sante.gouv.fr/IMG/pdf/Resultats_PHRIP_2011.pdf
format Online
Article
Text
id pubmed-4975735
institution National Center for Biotechnology Information
language English
publishDate 2016
publisher Springer International Publishing
record_format MEDLINE/PubMed
spelling pubmed-49757352016-08-18 Effect of dosimeter’s position on occupational radiation extremity dose measurement for nuclear medicine workers during (18)F-FDG preparation for PET/CT Salesses, Fabien Perez, Paul Maillard, Aline E. Blanchard, Julie Mallard, Sabine Bordenave, Laurence EJNMMI Phys Original Research BACKGROUND: The recent spread of positron emission tomography-computed tomography (PET/CT) poses extremity dosimetry challenges. The question arose whether the radiation dose measured by the ring thermoluminescent dosimeter usually worn on the proximal phalanx (P1) of the index finger measures doses that are representative of the true doses received by the upper extremities of the operators. A prospective individual dosimetry study was performed in which the personal equivalent dose Hp (0.07) received during a specific 2-[(18)F]fluoro-2-deoxy-d-glucose ((18)F-FDG) manual dose-dispensing procedure was measured in a paired design by two operational personal electronic dosimeters fitted on the palm side of the index finger, namely in the P1 and distal phalanx (P3) positions. The study participants were ten nuclear medicine technologists working in two nuclear medicine departments. The personal equivalent radiation doses received by the palm side of the proximal phalanx of the index finger [Hp (0.07)(P1)] and that received by the distal phalanx [Hp (0.07)(P3)] were compared. RESULTS: The median Hp (0.07)(P3)/Hp (0.07)(P1) ratio per participant varied between 1.0 and 2.5 (based on 23 to 31 measurements per participant). The 271 paired measurements revealed a crude Hp (0.07)(P3)/Hp (0.07)(P1) ratio of 1.67, significantly different from 1 (p = 0.0004, 95 % CI [1.35–2.07]). When adjusted on participant’s gender and mother vial activity, the ratio was similar (1.53, p = 0.003, 95 % CI [1.22–1.92]). CONCLUSIONS: The study demonstrated a significant disparity that may exist between the radiation doses measured in the P1 and P3 positions of operators during (18)F-FDG manipulation. These findings emphasize the importance of performing workplace dosimetry studies adapted to each radiopharmaceutical and manipulation thereof, aiming to guarantee optimal workers’ dosimetry monitoring schemes. TRIAL REGISTRATION: Hospital Nursing and Paramedical Research Program (PHRIP, 2011–2013) from the French Ministry of Health (DGOS), http://social-sante.gouv.fr/IMG/pdf/Resultats_PHRIP_2011.pdf Springer International Publishing 2016-08-05 /pmc/articles/PMC4975735/ /pubmed/27495913 http://dx.doi.org/10.1186/s40658-016-0152-5 Text en © The Author(s). 2016 Open AccessThis article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made.
spellingShingle Original Research
Salesses, Fabien
Perez, Paul
Maillard, Aline E.
Blanchard, Julie
Mallard, Sabine
Bordenave, Laurence
Effect of dosimeter’s position on occupational radiation extremity dose measurement for nuclear medicine workers during (18)F-FDG preparation for PET/CT
title Effect of dosimeter’s position on occupational radiation extremity dose measurement for nuclear medicine workers during (18)F-FDG preparation for PET/CT
title_full Effect of dosimeter’s position on occupational radiation extremity dose measurement for nuclear medicine workers during (18)F-FDG preparation for PET/CT
title_fullStr Effect of dosimeter’s position on occupational radiation extremity dose measurement for nuclear medicine workers during (18)F-FDG preparation for PET/CT
title_full_unstemmed Effect of dosimeter’s position on occupational radiation extremity dose measurement for nuclear medicine workers during (18)F-FDG preparation for PET/CT
title_short Effect of dosimeter’s position on occupational radiation extremity dose measurement for nuclear medicine workers during (18)F-FDG preparation for PET/CT
title_sort effect of dosimeter’s position on occupational radiation extremity dose measurement for nuclear medicine workers during (18)f-fdg preparation for pet/ct
topic Original Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4975735/
https://www.ncbi.nlm.nih.gov/pubmed/27495913
http://dx.doi.org/10.1186/s40658-016-0152-5
work_keys_str_mv AT salessesfabien effectofdosimeterspositiononoccupationalradiationextremitydosemeasurementfornuclearmedicineworkersduring18ffdgpreparationforpetct
AT perezpaul effectofdosimeterspositiononoccupationalradiationextremitydosemeasurementfornuclearmedicineworkersduring18ffdgpreparationforpetct
AT maillardalinee effectofdosimeterspositiononoccupationalradiationextremitydosemeasurementfornuclearmedicineworkersduring18ffdgpreparationforpetct
AT blanchardjulie effectofdosimeterspositiononoccupationalradiationextremitydosemeasurementfornuclearmedicineworkersduring18ffdgpreparationforpetct
AT mallardsabine effectofdosimeterspositiononoccupationalradiationextremitydosemeasurementfornuclearmedicineworkersduring18ffdgpreparationforpetct
AT bordenavelaurence effectofdosimeterspositiononoccupationalradiationextremitydosemeasurementfornuclearmedicineworkersduring18ffdgpreparationforpetct