Cargando…
Reproducibility of serum IgE, Ara h2 skin prick testing and fraction of exhaled nitric oxide for predicting clinical peanut allergy in children
BACKGROUND: Ara h2 sIgE serum levels improve the diagnostic accuracy for predicting peanut allergy, but the use of Ara h2 purified protein as a skin prick test (SPT), has not been substantially evaluated. The fraction of exhaled nitric oxide (FeNO) shows promise as a novel biomarker of peanut allerg...
Autores principales: | , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
BioMed Central
2016
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4975907/ https://www.ncbi.nlm.nih.gov/pubmed/27499764 http://dx.doi.org/10.1186/s13223-016-0143-z |
Sumario: | BACKGROUND: Ara h2 sIgE serum levels improve the diagnostic accuracy for predicting peanut allergy, but the use of Ara h2 purified protein as a skin prick test (SPT), has not been substantially evaluated. The fraction of exhaled nitric oxide (FeNO) shows promise as a novel biomarker of peanut allergy. Reproducibility of these measures has not been determined. The aim was to assess the accuracy and reproducibility (over a time-period of at least 12 months) of SPT to Ara h2 in comparison with four predictors of clinical peanut allergy (Peanut SPT, Ara h2 specific Immunoglobulin E (sIgE), Peanut sIgE and FeNO). METHODS: Twenty-seven children were recruited in a follow-up of a prospective cohort of fifty-six children at least 12 months after an open-labelled peanut food challenge. Their repeat assessment involved a questionnaire, SPT to peanut and Ara h2 purified protein, FeNO and sIgE to peanut and Ara h2 measurements. RESULTS: Ara h2 SPT was no worse in accuracy when compared with peanut SPT, FeNO, Ara h2 sIgE and peanut sIgE (AUC 0.908 compared with 0.887, 0.889, 0.935 and 0.804 respectively) for predicting allergic reaction at previous food challenge. SPT for peanut and Ara h2 demonstrated limited reproducibility (ICC = 0.51 and 0.44); while FeNO demonstrated good reproducibility (ICC = 0.73) and sIgE for peanut and Ara h2 were highly reproducible (ICC = 0.81 and 0.85). CONCLUSIONS: In this population, Ara h2 SPT was no worse in accuracy when compared with current testing for the evaluation of clinical peanut allergy, but had—like peanut SPT—poor reproducibility. FeNO, peanut sIgE and Ara h2 sIgE were consistently reproducible despite an interval of at least 12 months between the repeated measurements. ELECTRONIC SUPPLEMENTARY MATERIAL: The online version of this article (doi:10.1186/s13223-016-0143-z) contains supplementary material, which is available to authorized users. |
---|