Cargando…

The Application of a Contact Lens Sensor in Detecting 24-Hour Intraocular Pressure-Related Patterns

Glaucoma is one of the leading causes of blindness worldwide. Recent studies suggest that intraocular pressure (IOP) fluctuations, peaks, and rhythm are important factors in disease advancement. Yet, current glaucoma management remains hinged on single IOP measurements during clinic hours. To overco...

Descripción completa

Detalles Bibliográficos
Autores principales: Xu, Sarah C., Gauthier, Angela C., Liu, Ji
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Hindawi Publishing Corporation 2016
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4976175/
https://www.ncbi.nlm.nih.gov/pubmed/27525110
http://dx.doi.org/10.1155/2016/4727423
_version_ 1782446824015003648
author Xu, Sarah C.
Gauthier, Angela C.
Liu, Ji
author_facet Xu, Sarah C.
Gauthier, Angela C.
Liu, Ji
author_sort Xu, Sarah C.
collection PubMed
description Glaucoma is one of the leading causes of blindness worldwide. Recent studies suggest that intraocular pressure (IOP) fluctuations, peaks, and rhythm are important factors in disease advancement. Yet, current glaucoma management remains hinged on single IOP measurements during clinic hours. To overcome this limitation, 24-hour IOP monitoring devices have been employed and include self-tonometry, permanent IOP, and temporary IOP monitoring. This review discusses each IOP measuring strategy and focuses on the recently FDA-approved contact lens sensor (CLS). The CLS records IOP-related ocular patterns for 24 hours continuously. Using the CLS, IOP-related parameters have been found to be associated with the rate of visual field progression in primary open-angle glaucoma, disease progression in primary angle-closure glaucoma, and various clinical variables in ocular hypertension. The CLS has been used to quantify blink rate and limbal strain and measure the circadian rhythm in a variety of disease states including normal-tension glaucoma and thyroid eye disease. The effects of various IOP-lowering interventions were also characterized using the CLS. CLS provides a unique, safe, and well-tolerated way to study IOP-related patterns in a wide range of disease states. IOP-related patterns may help identify patients most at risk for disease progression and assist with the development of tailored treatments.
format Online
Article
Text
id pubmed-4976175
institution National Center for Biotechnology Information
language English
publishDate 2016
publisher Hindawi Publishing Corporation
record_format MEDLINE/PubMed
spelling pubmed-49761752016-08-14 The Application of a Contact Lens Sensor in Detecting 24-Hour Intraocular Pressure-Related Patterns Xu, Sarah C. Gauthier, Angela C. Liu, Ji J Ophthalmol Review Article Glaucoma is one of the leading causes of blindness worldwide. Recent studies suggest that intraocular pressure (IOP) fluctuations, peaks, and rhythm are important factors in disease advancement. Yet, current glaucoma management remains hinged on single IOP measurements during clinic hours. To overcome this limitation, 24-hour IOP monitoring devices have been employed and include self-tonometry, permanent IOP, and temporary IOP monitoring. This review discusses each IOP measuring strategy and focuses on the recently FDA-approved contact lens sensor (CLS). The CLS records IOP-related ocular patterns for 24 hours continuously. Using the CLS, IOP-related parameters have been found to be associated with the rate of visual field progression in primary open-angle glaucoma, disease progression in primary angle-closure glaucoma, and various clinical variables in ocular hypertension. The CLS has been used to quantify blink rate and limbal strain and measure the circadian rhythm in a variety of disease states including normal-tension glaucoma and thyroid eye disease. The effects of various IOP-lowering interventions were also characterized using the CLS. CLS provides a unique, safe, and well-tolerated way to study IOP-related patterns in a wide range of disease states. IOP-related patterns may help identify patients most at risk for disease progression and assist with the development of tailored treatments. Hindawi Publishing Corporation 2016 2016-07-25 /pmc/articles/PMC4976175/ /pubmed/27525110 http://dx.doi.org/10.1155/2016/4727423 Text en Copyright © 2016 Sarah C. Xu et al. https://creativecommons.org/licenses/by/4.0/ This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Review Article
Xu, Sarah C.
Gauthier, Angela C.
Liu, Ji
The Application of a Contact Lens Sensor in Detecting 24-Hour Intraocular Pressure-Related Patterns
title The Application of a Contact Lens Sensor in Detecting 24-Hour Intraocular Pressure-Related Patterns
title_full The Application of a Contact Lens Sensor in Detecting 24-Hour Intraocular Pressure-Related Patterns
title_fullStr The Application of a Contact Lens Sensor in Detecting 24-Hour Intraocular Pressure-Related Patterns
title_full_unstemmed The Application of a Contact Lens Sensor in Detecting 24-Hour Intraocular Pressure-Related Patterns
title_short The Application of a Contact Lens Sensor in Detecting 24-Hour Intraocular Pressure-Related Patterns
title_sort application of a contact lens sensor in detecting 24-hour intraocular pressure-related patterns
topic Review Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4976175/
https://www.ncbi.nlm.nih.gov/pubmed/27525110
http://dx.doi.org/10.1155/2016/4727423
work_keys_str_mv AT xusarahc theapplicationofacontactlenssensorindetecting24hourintraocularpressurerelatedpatterns
AT gauthierangelac theapplicationofacontactlenssensorindetecting24hourintraocularpressurerelatedpatterns
AT liuji theapplicationofacontactlenssensorindetecting24hourintraocularpressurerelatedpatterns
AT xusarahc applicationofacontactlenssensorindetecting24hourintraocularpressurerelatedpatterns
AT gauthierangelac applicationofacontactlenssensorindetecting24hourintraocularpressurerelatedpatterns
AT liuji applicationofacontactlenssensorindetecting24hourintraocularpressurerelatedpatterns